Loading…
Loading…
名称 | ID | 标签 | 描述 | 类型 | 源代码 |
---|---|---|---|---|---|
GetHealthStatus | 0403 | GetHealthStatus | msrc_UNKNOWN | 详细信息 | |
ResetCurrentHold_method | 41F1 | Reset Current Hold | msrc_UNKNOWN | 详细信息 | |
SetCurrentHold_method | 41F2 | Set Current hold | msrc_UNKNOWN | 详细信息 | |
SW_Write_Protection_method | 40AF | Modify SW Write Protection | Select software write protection status. For configuration parameters to be editable and calibrations to be performed, both hardware and software write protection has to disabled (off). | msrc_UNKNOWN | 详细信息 |
ReadSWRev_method | 409D | Software Rev | 现场设备软件版本——该版本对应现场设备内置的软件或固件。 | msrc_UNKNOWN | 详细信息 |
ReadHWRev_method | 409E | Hardware Rev | 硬件版本——现场设备的电子硬件对应的版本。 | msrc_UNKNOWN | 详细信息 |
Hart_HartAccessLevel_method | 412B | Set HART Access Level | Select 'Calibratoin' for Calibrate access level. Select 'Advanced' for Advanced access level. Select 'Service' for Service access level. | msrc_UNKNOWN | 详细信息 |
reset_config_flag | 42F1 | Reset configuration change | msrc_UNKNOWN | 详细信息 | |
method_read_unit | 4361 | msrc_UNKNOWN | 详细信息 | ||
method_upload_measurement_value | 4333 | msrc_UNKNOWN | 详细信息 | ||
method_download_measurement_value | 4332 | msrc_UNKNOWN | 详细信息 | ||
ResetPHCalStatus_method | 41F3 | Reset Calibration Status | msrc_UNKNOWN | 详细信息 | |
AutoBufferCalibration_method | 414E | Auto Buffer Calibration | Auto buffer calibration. Select calibration buffer type (one of the pre-defined or user-defined) and the two calibration points before running this procedure. The procedure performs the calibration steps. The sensor temperature is used for calibration. Device automatically detects pH and temperature stability before performing calibration | msrc_UNKNOWN | 详细信息 |
OnePointPVManualCal_method | 416E | One Point Manual Calibration | msrc_UNKNOWN | 详细信息 | |
TwoPointPVManualCal_method | 416F | Two Point Manual Calibration | Two-point Manual PV cal lets the user enter the two cal point values and the temperature of the calibration buffer. User manually determines when the process value is stable. | msrc_UNKNOWN | 详细信息 |
PHTemperatureCal_method | 40C7 | Temperature Calibration | The temperature calibration is used to calibrate the temperature input from the sensor against a standard known reading. | msrc_UNKNOWN | 详细信息 |
DetectTCType_methodpH | 414C | Detect TC Type | Starts the auto-recognition process for the temperature sensor. | msrc_UNKNOWN | 详细信息 |
ResettoDefaults_methodpH | 40AB | Reset to Defaults | Warning! The device will power cycle; reset most of configurable parameters to factory default values. The parameters that are not reset are - HART device address, serial number, hardware and software version numbers. | msrc_UNKNOWN | 详细信息 |
Reset_cal_methodpH | 40C9 | Restore Defaults | msrc_UNKNOWN | 详细信息 | |
ResetTCCalStatus_method | 41F6 | Reset Calibration Status | msrc_UNKNOWN | 详细信息 | |
PVZeroCal_method | 417E | PV Zero Cal | The process value's zero calibration | msrc_UNKNOWN | 详细信息 |
PVSpanCal_method | 417F | PV Span Cal | The process value's span calibration | msrc_UNKNOWN | 详细信息 |
TCTemperatureCal_method | 40D3 | Temperature Calibration | The temperature calibration is used to calibrate the temperature input from the sensor against a standard known reading. | msrc_UNKNOWN | 详细信息 |
DetectTCType_methodTC | 417D | Detect TC Type | Starts the auto-recognition process for the temperature sensor. | msrc_UNKNOWN | 详细信息 |
ResettoDefaults_methodTC | 40AE | Reset to Defaults | Warning! The device will power cycle; reset most of configurable parameters to factory default values. The parameters that are not reset are - HART device address, serial number, hardware and software version numbers. | msrc_UNKNOWN | 详细信息 |
Reset_cal_methodTC | 40D4 | Restore Defaults | Restore default calibration co-efficients. | msrc_UNKNOWN | 详细信息 |
ResetECCalStatus_method | 41F8 | Reset Calibration Status | msrc_UNKNOWN | 详细信息 | |
ECCondOrConcCalibration_method | 4146 | Start Cond/Conc Cal | msrc_UNKNOWN | 详细信息 | |
ECTemperatureCal_method | 40CC | Temperature Cal | msrc_UNKNOWN | 详细信息 | |
DetectTCType_methodEC | 4145 | Detect TC Type | Starts the auto-recognition process for the temperature sensor. | msrc_UNKNOWN | 详细信息 |
ResettoDefaults_methodEC | 40AC | Reset to Defaults | Warning! The device will power cycle; reset most of configurable parameters to factory default values. The parameters that are not reset are - HART device address, serial number, hardware and software version numbers. | msrc_UNKNOWN | 详细信息 |
Reset_cal_methodEC | 40CD | Restore Defaults | msrc_UNKNOWN | 详细信息 | |
ResetTECalStatus_method | 41FA | Reset Calibration Status | msrc_UNKNOWN | 详细信息 | |
TECondOrConcCalibration_method | 418B | Conductivity/Concentration cal | Calibration of a conductivity/Concentration process value. | msrc_UNKNOWN | 详细信息 |
TETemperatureCal_method | 40CF | Temperature Cal | msrc_UNKNOWN | 详细信息 | |
DetectTCType_methodTE | 418A | Detect TC Type | Starts the auto-recognition process for the temperature sensor. | msrc_UNKNOWN | 详细信息 |
ResettoDefaults_methodTE | 40AD | Reset to Defaults | Warning! The device will power cycle; reset most of configurable parameters to factory default values. The parameters that are not reset are - HART device address, serial number, hardware and software version numbers. | msrc_UNKNOWN | 详细信息 |
Reset_cal_methodTE | 40D0 | Restore Defaults | msrc_UNKNOWN | 详细信息 | |
device_master_reset | 1072 | 设备复位 | 设备复位——命令电子设备执行复位。该操作相当于将现场设备电源关闭然后再打开。 | msrc_UNKNOWN | 详细信息 |
transmitter_loop_test | 1023 | 回路测试 | 回路测试——允许用户将选择的模拟量输出手动调节至选择的常数输出值。 | msrc_UNKNOWN | 详细信息 |
transmitter_dac_trim | 1024 | Analog Output Trim | 数字到模拟修正——允许对选择的模拟量输出进行标定,在模拟量输出的操作端点有外部参考。 | msrc_UNKNOWN | 详细信息 |
leave_fixed_current_mode | 1003 | 退出固定电流模式 | 退出固定电流模式——使选择的模拟量输出退出输出为常数值的模式,使输出返回输出跟踪输入的模式。 | msrc_UNKNOWN | 详细信息 |
return_to_normal | 1016 | 中止返回正常 | msrc_UNKNOWN | 详细信息 | |
名称 | ID | 标签 | 描述 | 类型 | 源代码 |