Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
GetHealthStatus | 0403 | GetHealthStatus | msrc_UNKNOWN | Details | |
ResetCurrentHold_method | 41F1 | Reset Current Hold | msrc_UNKNOWN | Details | |
SetCurrentHold_method | 41F2 | Set Current hold | msrc_UNKNOWN | Details | |
SW_Write_Protection_method | 40AF | Modify SW Write Protection | Select software write protection status. For configuration parameters to be editable and calibrations to be performed, both hardware and software write protection has to disabled (off). | msrc_UNKNOWN | Details |
ReadSWRev_method | 409D | Software Rev | フィールド機器ソフトウェア レビジョン - これはソフトウェア又はファームウェアのレビジョンのことで, フィールド機器に書込まれています。 | msrc_UNKNOWN | Details |
ReadHWRev_method | 409E | Hardware Rev | ハードウェア レビジョン - フィールド機器のエレクトロニクス ハードウェアのレビジョンです。 | msrc_UNKNOWN | Details |
Hart_HartAccessLevel_method | 412B | Set HART Access Level | Select 'Calibratoin' for Calibrate access level. Select 'Advanced' for Advanced access level. Select 'Service' for Service access level. | msrc_UNKNOWN | Details |
reset_config_flag | 42F1 | Reset configuration change | msrc_UNKNOWN | Details | |
method_read_unit | 4361 | msrc_UNKNOWN | Details | ||
method_upload_measurement_value | 4333 | msrc_UNKNOWN | Details | ||
method_download_measurement_value | 4332 | msrc_UNKNOWN | Details | ||
ResetPHCalStatus_method | 41F3 | Reset Calibration Status | msrc_UNKNOWN | Details | |
AutoBufferCalibration_method | 414E | Auto Buffer Calibration | Auto buffer calibration. Select calibration buffer type (one of the pre-defined or user-defined) and the two calibration points before running this procedure. The procedure performs the calibration steps. The sensor temperature is used for calibration. Device automatically detects pH and temperature stability before performing calibration | msrc_UNKNOWN | Details |
OnePointPVManualCal_method | 416E | One Point Manual Calibration | msrc_UNKNOWN | Details | |
TwoPointPVManualCal_method | 416F | Two Point Manual Calibration | Two-point Manual PV cal lets the user enter the two cal point values and the temperature of the calibration buffer. User manually determines when the process value is stable. | msrc_UNKNOWN | Details |
PHTemperatureCal_method | 40C7 | Temperature Calibration | The temperature calibration is used to calibrate the temperature input from the sensor against a standard known reading. | msrc_UNKNOWN | Details |
DetectTCType_methodpH | 414C | Detect TC Type | Starts the auto-recognition process for the temperature sensor. | msrc_UNKNOWN | Details |
ResettoDefaults_methodpH | 40AB | Reset to Defaults | Warning! The device will power cycle; reset most of configurable parameters to factory default values. The parameters that are not reset are - HART device address, serial number, hardware and software version numbers. | msrc_UNKNOWN | Details |
Reset_cal_methodpH | 40C9 | Restore Defaults | msrc_UNKNOWN | Details | |
ResetTCCalStatus_method | 41F6 | Reset Calibration Status | msrc_UNKNOWN | Details | |
PVZeroCal_method | 417E | PV Zero Cal | The process value's zero calibration | msrc_UNKNOWN | Details |
PVSpanCal_method | 417F | PV Span Cal | The process value's span calibration | msrc_UNKNOWN | Details |
TCTemperatureCal_method | 40D3 | Temperature Calibration | The temperature calibration is used to calibrate the temperature input from the sensor against a standard known reading. | msrc_UNKNOWN | Details |
DetectTCType_methodTC | 417D | Detect TC Type | Starts the auto-recognition process for the temperature sensor. | msrc_UNKNOWN | Details |
ResettoDefaults_methodTC | 40AE | Reset to Defaults | Warning! The device will power cycle; reset most of configurable parameters to factory default values. The parameters that are not reset are - HART device address, serial number, hardware and software version numbers. | msrc_UNKNOWN | Details |
Reset_cal_methodTC | 40D4 | Restore Defaults | Restore default calibration co-efficients. | msrc_UNKNOWN | Details |
ResetECCalStatus_method | 41F8 | Reset Calibration Status | msrc_UNKNOWN | Details | |
ECCondOrConcCalibration_method | 4146 | Start Cond/Conc Cal | msrc_UNKNOWN | Details | |
ECTemperatureCal_method | 40CC | Temperature Cal | msrc_UNKNOWN | Details | |
DetectTCType_methodEC | 4145 | Detect TC Type | Starts the auto-recognition process for the temperature sensor. | msrc_UNKNOWN | Details |
ResettoDefaults_methodEC | 40AC | Reset to Defaults | Warning! The device will power cycle; reset most of configurable parameters to factory default values. The parameters that are not reset are - HART device address, serial number, hardware and software version numbers. | msrc_UNKNOWN | Details |
Reset_cal_methodEC | 40CD | Restore Defaults | msrc_UNKNOWN | Details | |
ResetTECalStatus_method | 41FA | Reset Calibration Status | msrc_UNKNOWN | Details | |
TECondOrConcCalibration_method | 418B | Conductivity/Concentration cal | Calibration of a conductivity/Concentration process value. | msrc_UNKNOWN | Details |
TETemperatureCal_method | 40CF | Temperature Cal | msrc_UNKNOWN | Details | |
DetectTCType_methodTE | 418A | Detect TC Type | Starts the auto-recognition process for the temperature sensor. | msrc_UNKNOWN | Details |
ResettoDefaults_methodTE | 40AD | Reset to Defaults | Warning! The device will power cycle; reset most of configurable parameters to factory default values. The parameters that are not reset are - HART device address, serial number, hardware and software version numbers. | msrc_UNKNOWN | Details |
Reset_cal_methodTE | 40D0 | Restore Defaults | msrc_UNKNOWN | Details | |
device_master_reset | 1072 | 機器リセット | 機器リセット - リセットを実行するようにエレクトロニクスに指示します。これは, フィールド機器の電源の切/入と等価です。 | msrc_UNKNOWN | Details |
transmitter_loop_test | 1023 | ループ テスト | ループ テスト - アナログ出力をユーザーが選択した値で固定出力します | msrc_UNKNOWN | Details |
transmitter_dac_trim | 1024 | Analog Output Trim | D/A トリム (デジタル/アナログ トリム) - オペレーティング エンド ポイントに対するアナログ出力と外部指示計とのキャリブレーションを行います。 | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | 固定電流モードを終ります | 現在の固定モードを終了 - アナログ出力を定数値のモードから移行させ, 出力が入力に応じて変わるモードに戻します。 | msrc_UNKNOWN | Details |
return_to_normal | 1016 | ノーマル モードに戻します | msrc_UNKNOWN | Details | |