Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
ejx_method_change_pv_assign | 403E | Change PV Assgn | msrc_UNKNOWN | Details | |
ejx_method_change_sv_assign | 403F | Change SV Assgn | msrc_UNKNOWN | Details | |
ejx_method_change_tv_assign | 4040 | Change TV Assgn | msrc_UNKNOWN | Details | |
ejx_method_change_qv_assign | 4041 | Change QV Assgn | msrc_UNKNOWN | Details | |
ejx_method_self_test_exp_1 | 4042 | msrc_UNKNOWN | Details | ||
ejx_method_self_test | 4043 | Auto teste | Self Test- Commands the device electronics to perform a selftest. Reports any errors that occured. | msrc_UNKNOWN | Details |
ejx_method_master_test_exp_1 | 4044 | msrc_UNKNOWN | Details | ||
ejx_method_master_test | 4045 | Teste mestre | Master Reset- Commands the device electronics to reset and perform a selftest. Reports any errors that occured. | msrc_UNKNOWN | Details |
ejx_method_scaled_dac_trim | 4046 | Ajuste escalonado D/A | Digital para ajuste analógico escalado- Permite a calibração da saída analógica selecionada com uma referência externa nos endpoints de operação da saída analógica | msrc_UNKNOWN | Details |
ejx_method_clear_dac_trim | 4047 | Clear D/A trim | Clear digital to analog trim- Resets the trim adjustment to the initial calibrated values that were set at factory. | msrc_UNKNOWN | Details |
ejx_method_return_to_normal_for_zero_trim | 4049 | Abortar retorno para normal | msrc_UNKNOWN | Details | |
ejx_method_zero_trim | 404A | DP Zero trim | Ajuste Zero- Faça a entrada do sensor a referencia de nova entrada zero | msrc_UNKNOWN | Details |
ejx_method_dp_trim | 404B | DP trim | Differential pressure trim- Executes full sensor trim with zero point adjustment by Lower Pt and span adjustment by Upper Pt. | msrc_UNKNOWN | Details |
ejx_method_clear_dp_sensor_trim | 404F | Clear DP trim | Clear differential pressure sensor trim- Resets the trim adjustment to the initial calibrated values that were set at factory. | msrc_UNKNOWN | Details |
ejx_method_p1_trim | 4050 | Pres 1 trim | Pressure 1 trim- Executes full sensor trim with zero point adjustment by Lower Pt and span adjustment by Upper Pt. | msrc_UNKNOWN | Details |
ejx_method_clear_p1_sensor_trim | 4052 | Clear Pres 1 trim | Clear pressure 1 sensor trim- Resets the trim adjustment to the initial calibrated values that were set at factory. | msrc_UNKNOWN | Details |
ejx_method_p2_trim | 4053 | Pres 2 trim | Pressure 2 trim- Executes full sensor trim with zero point adjustment by Lower Pt and span adjustment by Upper Pt. | msrc_UNKNOWN | Details |
ejx_method_clear_p2_sensor_trim | 4055 | Clear Pres 2 trim | Clear pressure 2 sensor trim- Resets the trim adjustment to the initial calibrated values that were set at factory. | msrc_UNKNOWN | Details |
ejx_method_error_log_view | 4056 | Error log view | Error log view- Displays the error records from log1(latest) to log4. | msrc_UNKNOWN | Details |
ejx_method_error_log_clear | 4065 | Error log clear | Error log clear- Clears the error records. | msrc_UNKNOWN | Details |
ejx_method_point_init | 4066 | X Y initialize | Initialize the X,Y coordinate point of the special curve. | msrc_UNKNOWN | Details |
ejx_method_point_init_sub | 4067 | msrc_UNKNOWN | Details | ||
ejx_method_set_engr_unit | 406C | Set Engr unit | Set engineering unit- Selects the engineering unit from the list. | msrc_UNKNOWN | Details |
ejx_method_modify_engr_unit | 406E | Modify Engr unit | Modify engineering unit- Modifies the engineering unit or sets a customized engineering unit. Enter a series of up to eight alphanumeric characters, spaces, or slashes (only first six characters are shown on LCD). Note that if you already select the unit at 'Set Engineering Unit,' the unit appears as a default. Then re-enter the unit but enter a space instead of a character to display the character in lowercase on LCD. For example, in order to show 'aBCd' on LCD, enter 'ABCD' first, then enter '_BC_'. | msrc_UNKNOWN | Details |
ejx_method_test_key | 4071 | Test Key | msrc_UNKNOWN | Details | |
ejx_method_write_enable_10min | 4078 | Enable wrt 10min | Enable parameter change for 10 min.- releases the software write protection for 10 minutes when the password is entered. | msrc_UNKNOWN | Details |
ejx_method_change_to_new_password | 407B | New password | New password- Sets or changes the password for software write protection. | msrc_UNKNOWN | Details |
err_abort_without_func_key_disp | 407A | Aborting | msrc_UNKNOWN | Details | |
normal_exit_for_chg_passwd | 407D | Exiting | msrc_UNKNOWN | Details | |
ejx_method_set_diag_mode | 407E | Set Diag Mode | msrc_UNKNOWN | Details | |
ejx_method_reset_configuration_change_flag | 4080 | Reset Cfg chng flag | Reset Configuration changed flag. | msrc_UNKNOWN | Details |
ejx_method_squawk | 4081 | Squawk | Faça o Squawk do dispositivo de campo- Isso causa o dispositivo para alerta visualmente, audivelmente ou mecanicamente ou que permite os técnico para identificá-lo | msrc_UNKNOWN | Details |
ejx_method_simulate | 4082 | Device vars simulate | Simulate device variable with status. | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period1 | 408A | Set Burst Period | Configure Burst Period | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period2 | 408B | Set Burst Period | Configure Burst Period | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period3 | 408C | Set Burst Period | Configure Burst Period | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period_sub | 408D | msrc_UNKNOWN | Details | ||
ejx_method_set_burst_trigger1 | 408E | Set Burst Trigger | Configure Burst Trigger | msrc_UNKNOWN | Details |
ejx_method_set_burst_trigger2 | 408F | Set Burst Trigger | Configure Burst Trigger | msrc_UNKNOWN | Details |
ejx_method_set_burst_trigger3 | 4090 | Set Burst Trigger | Configure Burst Trigger | msrc_UNKNOWN | Details |
ejx_method_set_burst_trigger_sub | 4091 | msrc_UNKNOWN | Details | ||
ejx_method_event_time_setting | 4092 | Set Event Notification Timing | Configure Event Notification Timing | msrc_UNKNOWN | Details |
ejx_method_acknowledge_event_notification | 4094 | Acknowledge Event Notification | Acknowledge the latched event instance that associated with the event specification number. | msrc_UNKNOWN | Details |
send_warning | 1399 | Enviar alerta | Enviar alerta – Produzir uma notificação de código de unidades para o usuário | msrc_UNKNOWN | Details |
method_reset_cond_status_map | 42A9 | Reset condensed status map | Reset the Condensed Status Map to the default values. | msrc_UNKNOWN | Details |
ejx_method_status_sim | 41EA | Status simulate | Status Simulation allows a Field Device Status bit or a bit in the Command 48 response to be manipulated. | msrc_UNKNOWN | Details |
transmitter_loop_test | 1023 | Teste de malha | Teste de malha- Permite o usuário a manipular manualemnte a saída analógica para o valor de saída de constante selecionada | msrc_UNKNOWN | Details |
transmitter_dac_trim | 1024 | Ajuste D/A | Digital para ajuste analógico- Permite a calibração da saída analógica selecionada com uma referência externa nos endpoints de operação da saída analógica | msrc_UNKNOWN | Details |
warning_message | 1017 | Ajustar malha para manual | msrc_UNKNOWN | Details | |
return_to_normal | 1016 | Abortar retorno para normal | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | Deixar o modo fixado atual | Modo atual de deixar fixado- Leva uma saída analógica para fora do modo onde a saída foi um valor constant, e retorna a saída para o modo onde a saída segue a entrada | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |