Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
ejx_method_change_pv_assign | 403E | Change PV Assgn | msrc_UNKNOWN | Details | |
ejx_method_change_sv_assign | 403F | Change SV Assgn | msrc_UNKNOWN | Details | |
ejx_method_change_tv_assign | 4040 | Change TV Assgn | msrc_UNKNOWN | Details | |
ejx_method_change_qv_assign | 4041 | Change QV Assgn | msrc_UNKNOWN | Details | |
ejx_method_self_test_exp_1 | 4042 | msrc_UNKNOWN | Details | ||
ejx_method_self_test | 4043 | Selbsttest | Self Test- Commands the device electronics to perform a selftest. Reports any errors that occured. | msrc_UNKNOWN | Details |
ejx_method_master_test_exp_1 | 4044 | msrc_UNKNOWN | Details | ||
ejx_method_master_test | 4045 | Master Test | Master Reset- Commands the device electronics to reset and perform a selftest. Reports any errors that occured. | msrc_UNKNOWN | Details |
ejx_method_scaled_dac_trim | 4046 | Skal.D/A Abgleich | Digital zu Analog Abgleich- Ermöglicht den Abgleich der Endpunkten des Analogausgangs mit einer externen Referenz | msrc_UNKNOWN | Details |
ejx_method_clear_dac_trim | 4047 | Clear D/A trim | Clear digital to analog trim- Resets the trim adjustment to the initial calibrated values that were set at factory. | msrc_UNKNOWN | Details |
ejx_method_return_to_normal_for_zero_trim | 4049 | Abbruch Rückk. zu normal | msrc_UNKNOWN | Details | |
ejx_method_zero_trim | 404A | DP Zero trim | Meßanfangs-Abgleich- Der Meßanfang wird dem aktuellen Sensoreingangswert gleichgestellt | msrc_UNKNOWN | Details |
ejx_method_dp_trim | 404B | DP trim | Differential pressure trim- Executes full sensor trim with zero point adjustment by Lower Pt and span adjustment by Upper Pt. | msrc_UNKNOWN | Details |
ejx_method_clear_dp_sensor_trim | 404F | Clear DP trim | Clear differential pressure sensor trim- Resets the trim adjustment to the initial calibrated values that were set at factory. | msrc_UNKNOWN | Details |
ejx_method_p1_trim | 4050 | Pres 1 trim | Pressure 1 trim- Executes full sensor trim with zero point adjustment by Lower Pt and span adjustment by Upper Pt. | msrc_UNKNOWN | Details |
ejx_method_clear_p1_sensor_trim | 4052 | Clear Pres 1 trim | Clear pressure 1 sensor trim- Resets the trim adjustment to the initial calibrated values that were set at factory. | msrc_UNKNOWN | Details |
ejx_method_p2_trim | 4053 | Pres 2 trim | Pressure 2 trim- Executes full sensor trim with zero point adjustment by Lower Pt and span adjustment by Upper Pt. | msrc_UNKNOWN | Details |
ejx_method_clear_p2_sensor_trim | 4055 | Clear Pres 2 trim | Clear pressure 2 sensor trim- Resets the trim adjustment to the initial calibrated values that were set at factory. | msrc_UNKNOWN | Details |
ejx_method_error_log_view | 4056 | Error log view | Error log view- Displays the error records from log1(latest) to log4. | msrc_UNKNOWN | Details |
ejx_method_error_log_clear | 4065 | Error log clear | Error log clear- Clears the error records. | msrc_UNKNOWN | Details |
ejx_method_point_init | 4066 | X Y initialize | Initialize the X,Y coordinate point of the special curve. | msrc_UNKNOWN | Details |
ejx_method_point_init_sub | 4067 | msrc_UNKNOWN | Details | ||
ejx_method_set_engr_unit | 406C | Set Engr unit | Set engineering unit- Selects the engineering unit from the list. | msrc_UNKNOWN | Details |
ejx_method_modify_engr_unit | 406E | Modify Engr unit | Modify engineering unit- Modifies the engineering unit or sets a customized engineering unit. Enter a series of up to eight alphanumeric characters, spaces, or slashes (only first six characters are shown on LCD). Note that if you already select the unit at 'Set Engineering Unit,' the unit appears as a default. Then re-enter the unit but enter a space instead of a character to display the character in lowercase on LCD. For example, in order to show 'aBCd' on LCD, enter 'ABCD' first, then enter '_BC_'. | msrc_UNKNOWN | Details |
ejx_method_test_key | 4071 | Test Key | msrc_UNKNOWN | Details | |
ejx_method_write_enable_10min | 4078 | Enable wrt 10min | Enable parameter change for 10 min.- releases the software write protection for 10 minutes when the password is entered. | msrc_UNKNOWN | Details |
ejx_method_change_to_new_password | 407B | New password | New password- Sets or changes the password for software write protection. | msrc_UNKNOWN | Details |
err_abort_without_func_key_disp | 407A | Aborting | msrc_UNKNOWN | Details | |
normal_exit_for_chg_passwd | 407D | Exiting | msrc_UNKNOWN | Details | |
ejx_method_set_diag_mode | 407E | Set Diag Mode | msrc_UNKNOWN | Details | |
ejx_method_reset_configuration_change_flag | 4080 | Reset Cfg chng flag | Reset Configuration changed flag. | msrc_UNKNOWN | Details |
ejx_method_squawk | 4081 | Squawk | Feldgerät sich bemerkbar machen lassen- veranlasst das Gerät einen visuellen, akustischen oder mechanischen Alarm auszugeben, um den Technikern eine Identifizierung zu ermöglichen | msrc_UNKNOWN | Details |
ejx_method_simulate | 4082 | Device vars simulate | Simulate device variable with status. | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period1 | 408A | Set Burst Period | Configure Burst Period | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period2 | 408B | Set Burst Period | Configure Burst Period | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period3 | 408C | Set Burst Period | Configure Burst Period | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period_sub | 408D | msrc_UNKNOWN | Details | ||
ejx_method_set_burst_trigger1 | 408E | Set Burst Trigger | Configure Burst Trigger | msrc_UNKNOWN | Details |
ejx_method_set_burst_trigger2 | 408F | Set Burst Trigger | Configure Burst Trigger | msrc_UNKNOWN | Details |
ejx_method_set_burst_trigger3 | 4090 | Set Burst Trigger | Configure Burst Trigger | msrc_UNKNOWN | Details |
ejx_method_set_burst_trigger_sub | 4091 | msrc_UNKNOWN | Details | ||
ejx_method_event_time_setting | 4092 | Set Event Notification Timing | Configure Event Notification Timing | msrc_UNKNOWN | Details |
ejx_method_acknowledge_event_notification | 4094 | Acknowledge Event Notification | Acknowledge the latched event instance that associated with the event specification number. | msrc_UNKNOWN | Details |
send_warning | 1399 | Sende Warnung | Sende Warnung- Mitteilung über Einheitcodes an den Anwender | msrc_UNKNOWN | Details |
method_reset_cond_status_map | 42A9 | Reset condensed status map | Reset the Condensed Status Map to the default values. | msrc_UNKNOWN | Details |
ejx_method_status_sim | 41EA | Status simulate | Status Simulation allows a Field Device Status bit or a bit in the Command 48 response to be manipulated. | msrc_UNKNOWN | Details |
transmitter_loop_test | 1023 | Messkreistest | Meßkreistest- ermöglicht es, den Analogausgang manuell auf einen gewünschten konstanten Wert einzustellen | msrc_UNKNOWN | Details |
transmitter_dac_trim | 1024 | D/A Abgleich | Digital zu Analog Abgleich- Ermöglicht den Abgleich der Endpunkten des gewählten Analogausgangs mit einer externen Referenz | msrc_UNKNOWN | Details |
warning_message | 1017 | Kreis auf Handbetrieb | msrc_UNKNOWN | Details | |
return_to_normal | 1016 | Abbruch Rückk. zu normal | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | Fest-Stromausgang beenden | Konstantstrom Modus verlassen- Der Analogausgang war auf einen bestimmten Ausgangswert eingefroren. Es erfolgt die Rückkehr zu der Betriebsart, bei der der Analogausgang wieder dem Prozeßwert folgt | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |