Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
ejx_method_change_pv_assign | 403E | Change PV Assgn | msrc_UNKNOWN | Details | |
ejx_method_change_sv_assign | 403F | Change SV Assgn | msrc_UNKNOWN | Details | |
ejx_method_change_tv_assign | 4040 | Change TV Assgn | msrc_UNKNOWN | Details | |
ejx_method_change_qv_assign | 4041 | Change QV Assgn | msrc_UNKNOWN | Details | |
ejx_method_self_test_exp_1 | 4042 | msrc_UNKNOWN | Details | ||
ejx_method_self_test | 4043 | Self test | Self Test- Commands the device electronics to perform a selftest. Reports any errors that occured. | msrc_UNKNOWN | Details |
ejx_method_master_test_exp_1 | 4044 | msrc_UNKNOWN | Details | ||
ejx_method_master_test | 4045 | Master test | Master Reset- Commands the device electronics to reset and perform a selftest. Reports any errors that occured. | msrc_UNKNOWN | Details |
ejx_method_scaled_dac_trim | 4046 | Scaled D/A trim | Digital to Analog Scaled Trim- Allows the calibration of the Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
ejx_method_clear_dac_trim | 4047 | Clear D/A trim | Clear digital to analog trim- Resets the trim adjustment to the initial calibrated values that were set at factory. | msrc_UNKNOWN | Details |
ejx_method_return_to_normal_for_zero_trim | 4049 | Aborting return to normal | msrc_UNKNOWN | Details | |
ejx_method_zero_trim | 404A | DP Zero trim | Zero trim- Make the sensor input the new zero input reference | msrc_UNKNOWN | Details |
ejx_method_dp_trim | 404B | DP trim | Differential pressure trim- Executes full sensor trim with zero point adjustment by Lower Pt and span adjustment by Upper Pt. | msrc_UNKNOWN | Details |
ejx_method_clear_dp_sensor_trim | 404F | Clear DP trim | Clear differential pressure sensor trim- Resets the trim adjustment to the initial calibrated values that were set at factory. | msrc_UNKNOWN | Details |
ejx_method_p1_trim | 4050 | Pres 1 trim | Pressure 1 trim- Executes full sensor trim with zero point adjustment by Lower Pt and span adjustment by Upper Pt. | msrc_UNKNOWN | Details |
ejx_method_clear_p1_sensor_trim | 4052 | Clear Pres 1 trim | Clear pressure 1 sensor trim- Resets the trim adjustment to the initial calibrated values that were set at factory. | msrc_UNKNOWN | Details |
ejx_method_p2_trim | 4053 | Pres 2 trim | Pressure 2 trim- Executes full sensor trim with zero point adjustment by Lower Pt and span adjustment by Upper Pt. | msrc_UNKNOWN | Details |
ejx_method_clear_p2_sensor_trim | 4055 | Clear Pres 2 trim | Clear pressure 2 sensor trim- Resets the trim adjustment to the initial calibrated values that were set at factory. | msrc_UNKNOWN | Details |
ejx_method_error_log_view | 4056 | Error log view | Error log view- Displays the error records from log1(latest) to log4. | msrc_UNKNOWN | Details |
ejx_method_error_log_clear | 4065 | Error log clear | Error log clear- Clears the error records. | msrc_UNKNOWN | Details |
ejx_method_point_init | 4066 | X Y initialize | Initialize the X,Y coordinate point of the special curve. | msrc_UNKNOWN | Details |
ejx_method_point_init_sub | 4067 | msrc_UNKNOWN | Details | ||
ejx_method_set_engr_unit | 406C | Set Engr unit | Set engineering unit- Selects the engineering unit from the list. | msrc_UNKNOWN | Details |
ejx_method_modify_engr_unit | 406E | Modify Engr unit | Modify engineering unit- Modifies the engineering unit or sets a customized engineering unit. Enter a series of up to eight alphanumeric characters, spaces, or slashes (only first six characters are shown on LCD). Note that if you already select the unit at 'Set Engineering Unit,' the unit appears as a default. Then re-enter the unit but enter a space instead of a character to display the character in lowercase on LCD. For example, in order to show 'aBCd' on LCD, enter 'ABCD' first, then enter '_BC_'. | msrc_UNKNOWN | Details |
ejx_method_test_key | 4071 | Test Key | msrc_UNKNOWN | Details | |
ejx_method_write_enable_10min | 4078 | Enable wrt 10min | Enable parameter change for 10 min.- releases the software write protection for 10 minutes when the password is entered. | msrc_UNKNOWN | Details |
ejx_method_change_to_new_password | 407B | New password | New password- Sets or changes the password for software write protection. | msrc_UNKNOWN | Details |
err_abort_without_func_key_disp | 407A | Aborting | msrc_UNKNOWN | Details | |
normal_exit_for_chg_passwd | 407D | Exiting | msrc_UNKNOWN | Details | |
ejx_method_set_diag_mode | 407E | Set Diag Mode | msrc_UNKNOWN | Details | |
ejx_method_reset_configuration_change_flag | 4080 | Reset Cfg chng flag | Reset Configuration changed flag. | msrc_UNKNOWN | Details |
ejx_method_squawk | 4081 | Segnalazione | Make the Field Device Squawk- This causes the device to visually, audibly or mechanically alert to allow technicans to idendify it | msrc_UNKNOWN | Details |
ejx_method_simulate | 4082 | Device vars simulate | Simulate device variable with status. | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period1 | 408A | Set Burst Period | Configure Burst Period | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period2 | 408B | Set Burst Period | Configure Burst Period | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period3 | 408C | Set Burst Period | Configure Burst Period | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period_sub | 408D | msrc_UNKNOWN | Details | ||
ejx_method_set_burst_trigger1 | 408E | Set Burst Trigger | Configure Burst Trigger | msrc_UNKNOWN | Details |
ejx_method_set_burst_trigger2 | 408F | Set Burst Trigger | Configure Burst Trigger | msrc_UNKNOWN | Details |
ejx_method_set_burst_trigger3 | 4090 | Set Burst Trigger | Configure Burst Trigger | msrc_UNKNOWN | Details |
ejx_method_set_burst_trigger_sub | 4091 | msrc_UNKNOWN | Details | ||
ejx_method_event_time_setting | 4092 | Set Event Notification Timing | Configure Event Notification Timing | msrc_UNKNOWN | Details |
ejx_method_acknowledge_event_notification | 4094 | Acknowledge Event Notification | Acknowledge the latched event instance that associated with the event specification number. | msrc_UNKNOWN | Details |
send_warning | 1399 | Send warning | Send Warning- Yields a units code notice to the User | msrc_UNKNOWN | Details |
method_reset_cond_status_map | 42A9 | Reset condensed status map | Reset the Condensed Status Map to the default values. | msrc_UNKNOWN | Details |
ejx_method_status_sim | 41EA | Status simulate | Status Simulation allows a Field Device Status bit or a bit in the Command 48 response to be manipulated. | msrc_UNKNOWN | Details |
transmitter_loop_test | 1023 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
transmitter_dac_trim | 1024 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |