Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
setup_range_values | 4152 | Range Configuration | Configures output range | msrc_UNKNOWN | Details |
read_dv_max_min | 4140 | Read dv max/min log | Reads the device variable maximum and minimum logged values | msrc_UNKNOWN | Details |
reset_dv_max_min | 4141 | Reset dv max/min log | Resets the device variable maximum and minimum logged values | msrc_UNKNOWN | Details |
enable_dv_simulation | 4142 | Enable dv simulation | Enable device variable simulation | msrc_UNKNOWN | Details |
disable_dv_simulation | 4143 | Disable dv simulation | Disable device variable simulation | msrc_UNKNOWN | Details |
update_number_wires | 4033 | Update Number of Wires | msrc_UNKNOWN | Details | |
update_probe_dv1_4 | 4034 | Update Device Variable 1 to 4 Probe Type | msrc_UNKNOWN | Details | |
write_protect_on | 413D | Write protect | Write protects the device, if correct password is entered | msrc_UNKNOWN | Details |
write_protect_off | 413E | Write enable | Write enables the device, if correct password is previously entered | msrc_UNKNOWN | Details |
set_new_password | 413F | New password | Sets a new password for write protection, if correct password is entered | msrc_UNKNOWN | Details |
set_output_limits_namur | 4168 | Set limits = NAMUR | Sets the analog output limits to 3.8 mA and 20.5 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
before_poll | 4189 | Before polling | msrc_UNKNOWN | Details | |
put_in_manual | 418A | Loop in manual | msrc_UNKNOWN | Details | |
back_to_normal | 418B | Back to normal | msrc_UNKNOWN | Details | |
restore_configuration | 418C | Restoring configuration | msrc_UNKNOWN | Details | |
broken_namur_down | 416B | NAMUR down | Enables broken sensor error detection, and sets the error output value to 3.5 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
broken_namur_up | 416C | NAMUR up | Enables broken sensor error detection, and sets the error output value to 23 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
shorted_namur_down | 416D | NAMUR down | Enables shorted sensor error detection, and sets the error output value to 3.5 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
shorted_namur_up | 416E | NAMUR up | Enables shorted sensor error detection, and sets the error output value to 23 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
override_dac_trim | 413C | Override D/A trim | Overrides any previously D/A trimming by restoring factory calibration values | msrc_UNKNOWN | Details |
update_trend_results | 4158 | Update Trend Results | Method to update the trend results, digital values and status' | msrc_UNKNOWN | Details |
set_date_time | 4156 | Set Real-Time Clock | Method to set date and time to set the real-time clock in the field device | msrc_UNKNOWN | Details |
enter_sensor_configuration | 4155 | Sensor configuration | Configures sensor 1, sensor 2 and CJC sensor | msrc_UNKNOWN | Details |
transmitter_loop_test | 1023 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
transmitter_dac_trim | 1024 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
device_variable_trim | 1080 | Device variable trim | Trim variabile dispositivo - Consente di regolare linearmente la misura di taratura di una variabile dispositivo. Il punto di trim che viene inviato al dispositivo deve rappresentare il valore della variabile di processo attualmente applicata. | msrc_UNKNOWN | Details |
device_variable_trim_reset | 1083 | Device variable trim reset | Reset trim variabile dispositivo - Consente di impostare la variabile dispositivo sul suo trim di fabbrica predefinito. | msrc_UNKNOWN | Details |
device_variable_zero_trim | 1085 | Dev var zero trim | Zero trim- Make the sensor input the new zero input reference | msrc_UNKNOWN | Details |
device_master_reset | 1072 | Device reset | Reset dispositivo - Fornisce un comando all’elettronica affinché esegua un reset Questo equivale a spegnere e riaccendere il dispositivo di campo. | msrc_UNKNOWN | Details |
applied_rerange | 1007 | Apply values | Applied values- Perform a device rerange by applying the desired Upper Range Value and Lower Range Values to the device input | msrc_UNKNOWN | Details |
trim_warning | 1081 | Trim warning | msrc_UNKNOWN | Details | |
Name | ID | Label | Description | Type | Source |