Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
setup_range_values | 4152 | Range Configuration | Configures output range | msrc_UNKNOWN | Details |
read_dv_max_min | 4140 | Read dv max/min log | Reads the device variable maximum and minimum logged values | msrc_UNKNOWN | Details |
reset_dv_max_min | 4141 | Reset dv max/min log | Resets the device variable maximum and minimum logged values | msrc_UNKNOWN | Details |
enable_dv_simulation | 4142 | Enable dv simulation | Enable device variable simulation | msrc_UNKNOWN | Details |
disable_dv_simulation | 4143 | Disable dv simulation | Disable device variable simulation | msrc_UNKNOWN | Details |
update_number_wires | 4033 | Update Number of Wires | msrc_UNKNOWN | Details | |
update_probe_dv1_4 | 4034 | Update Device Variable 1 to 4 Probe Type | msrc_UNKNOWN | Details | |
write_protect_on | 413D | Write protect | Write protects the device, if correct password is entered | msrc_UNKNOWN | Details |
write_protect_off | 413E | Write enable | Write enables the device, if correct password is previously entered | msrc_UNKNOWN | Details |
set_new_password | 413F | New password | Sets a new password for write protection, if correct password is entered | msrc_UNKNOWN | Details |
set_output_limits_namur | 4168 | Set limits = NAMUR | Sets the analog output limits to 3.8 mA and 20.5 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
before_poll | 4189 | Before polling | msrc_UNKNOWN | Details | |
put_in_manual | 418A | Loop in manual | msrc_UNKNOWN | Details | |
back_to_normal | 418B | Back to normal | msrc_UNKNOWN | Details | |
restore_configuration | 418C | Restoring configuration | msrc_UNKNOWN | Details | |
broken_namur_down | 416B | NAMUR down | Enables broken sensor error detection, and sets the error output value to 3.5 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
broken_namur_up | 416C | NAMUR up | Enables broken sensor error detection, and sets the error output value to 23 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
shorted_namur_down | 416D | NAMUR down | Enables shorted sensor error detection, and sets the error output value to 3.5 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
shorted_namur_up | 416E | NAMUR up | Enables shorted sensor error detection, and sets the error output value to 23 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
override_dac_trim | 413C | Override D/A trim | Overrides any previously D/A trimming by restoring factory calibration values | msrc_UNKNOWN | Details |
update_trend_results | 4158 | Update Trend Results | Method to update the trend results, digital values and status' | msrc_UNKNOWN | Details |
set_date_time | 4156 | Set Real-Time Clock | Method to set date and time to set the real-time clock in the field device | msrc_UNKNOWN | Details |
enter_sensor_configuration | 4155 | Sensor configuration | Configures sensor 1, sensor 2 and CJC sensor | msrc_UNKNOWN | Details |
transmitter_loop_test | 1023 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
transmitter_dac_trim | 1024 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
device_variable_trim | 1080 | Device variable trim | Device Variable Trim- Allows for the calibration measurement of a device variable to be adjusted linearly. The trim point that is sent to the device must represent the presently applied process variable value. | msrc_UNKNOWN | Details |
device_variable_trim_reset | 1083 | Device variable trim reset | Device Variable Trim Reset- Allows for the device variable to be set to its default factory trim. | msrc_UNKNOWN | Details |
device_variable_zero_trim | 1085 | Dev var zero trim | Zero trim- Make the sensor input the new zero input reference | msrc_UNKNOWN | Details |
device_master_reset | 1072 | Device reset | Device Reset- Commands the electronics to perform a reset. This is equivalent to cycling the power off and then back on to the field device. | msrc_UNKNOWN | Details |
applied_rerange | 1007 | Apply values | Applied values- Perform a device rerange by applying the desired Upper Range Value and Lower Range Values to the device input | msrc_UNKNOWN | Details |
trim_warning | 1081 | Trim warning | msrc_UNKNOWN | Details | |
Name | ID | Label | Description | Type | Source |