Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
setup_range_values | 4152 | Range Configuration | Configures output range | msrc_UNKNOWN | Details |
read_dv_max_min | 4140 | Read dv max/min log | Reads the device variable maximum and minimum logged values | msrc_UNKNOWN | Details |
reset_dv_max_min | 4141 | Reset dv max/min log | Resets the device variable maximum and minimum logged values | msrc_UNKNOWN | Details |
enable_dv_simulation | 4142 | Enable dv simulation | Enable device variable simulation | msrc_UNKNOWN | Details |
disable_dv_simulation | 4143 | Disable dv simulation | Disable device variable simulation | msrc_UNKNOWN | Details |
update_number_wires | 4033 | Update Number of Wires | msrc_UNKNOWN | Details | |
update_probe_dv1_4 | 4034 | Update Device Variable 1 to 4 Probe Type | msrc_UNKNOWN | Details | |
write_protect_on | 413D | Write protect | Write protects the device, if correct password is entered | msrc_UNKNOWN | Details |
write_protect_off | 413E | Write enable | Write enables the device, if correct password is previously entered | msrc_UNKNOWN | Details |
set_new_password | 413F | New password | Sets a new password for write protection, if correct password is entered | msrc_UNKNOWN | Details |
set_output_limits_namur | 4168 | Set limits = NAMUR | Sets the analog output limits to 3.8 mA and 20.5 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
before_poll | 4189 | Before polling | msrc_UNKNOWN | Details | |
put_in_manual | 418A | Loop in manual | msrc_UNKNOWN | Details | |
back_to_normal | 418B | Back to normal | msrc_UNKNOWN | Details | |
restore_configuration | 418C | Restoring configuration | msrc_UNKNOWN | Details | |
broken_namur_down | 416B | NAMUR down | Enables broken sensor error detection, and sets the error output value to 3.5 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
broken_namur_up | 416C | NAMUR up | Enables broken sensor error detection, and sets the error output value to 23 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
shorted_namur_down | 416D | NAMUR down | Enables shorted sensor error detection, and sets the error output value to 3.5 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
shorted_namur_up | 416E | NAMUR up | Enables shorted sensor error detection, and sets the error output value to 23 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
override_dac_trim | 413C | Override D/A trim | Overrides any previously D/A trimming by restoring factory calibration values | msrc_UNKNOWN | Details |
update_trend_results | 4158 | Update Trend Results | Method to update the trend results, digital values and status' | msrc_UNKNOWN | Details |
set_date_time | 4156 | Set Real-Time Clock | Method to set date and time to set the real-time clock in the field device | msrc_UNKNOWN | Details |
enter_sensor_configuration | 4155 | Sensor configuration | Configures sensor 1, sensor 2 and CJC sensor | msrc_UNKNOWN | Details |
transmitter_loop_test | 1023 | Messkreistest | Meßkreistest- ermöglicht es, den Analogausgang manuell auf einen gewünschten konstanten Wert einzustellen | msrc_UNKNOWN | Details |
transmitter_dac_trim | 1024 | D/A Abgleich | Digital zu Analog Abgleich- Ermöglicht den Abgleich der Endpunkten des gewählten Analogausgangs mit einer externen Referenz | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Fest-Stromausgang beenden | Konstantstrom Modus verlassen- Der Analogausgang war auf einen bestimmten Ausgangswert eingefroren. Es erfolgt die Rückkehr zu der Betriebsart, bei der der Analogausgang wieder dem Prozeßwert folgt | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Abbruch Rückk. zu normal | msrc_UNKNOWN | Details | |
warning_message | 1017 | Kreis auf Handbetrieb | msrc_UNKNOWN | Details | |
device_variable_trim | 1080 | Einstellung Gerätevar. | Gerätevariablenabgleich- erlaubt für die Eichungsmessung einer Gerätevariablen, dass diese geradlinig abgeglichen wird. Dabei muss der am Gerät eingestellte Abgleichpunkt dem aktuellen Wert der Prozessvariablen entsprechen. | msrc_UNKNOWN | Details |
device_variable_trim_reset | 1083 | Device variable trim reset | Reset des Gerätevariablenabgleichs- ermöglicht es die Gerätevariable auf die Werkseinstellungen zurückzusetzen. | msrc_UNKNOWN | Details |
device_variable_zero_trim | 1085 | Abgleich Gerätenullp. | Meßanfangs-Abgleich- Der Meßanfang wird dem aktuellen Sensoreingangswert gleichgestellt | msrc_UNKNOWN | Details |
device_master_reset | 1072 | Gerätetest | Geräte Reset- weist die Elektronik an einen Reset durchzuführen. Dies kommt einem Ab- und Einschalten des Feldgerätes gleich. | msrc_UNKNOWN | Details |
applied_rerange | 1007 | Werte beaufschl. | Werte übernehmen- Ausführung einer Bereichsneueinstellung durch übernahme der gewünschten Meßanfang und Meßende an dem Prozeßeingang des Gerätes | msrc_UNKNOWN | Details |
trim_warning | 1081 | Warnung einstellen | msrc_UNKNOWN | Details | |
Name | ID | Label | Description | Type | Source |