Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
view_xmtr_status_method | 409B | View Status | Reports any currently active device status information. | msrc_UNKNOWN | Details |
view_error_log_method | 409C | View Error Log | Last in/first out list of system messages. | msrc_UNKNOWN | Details |
error_log_abort | 415A | msrc_UNKNOWN | Details | ||
clear_error_log_method | 409D | Clear Error Log | Pressing 'ENTER' clears the Error Log. | msrc_UNKNOWN | Details |
enter_password_method | 409E | Enter Password | The correct password must be entered to modify any of the parameters in the following menus. | msrc_UNKNOWN | Details |
perform_elect_zero_method | 40FD | Perform Zero | To perform an electronic zero, short terminals 8 and 9 of the transducer connector together and press ENTER. Remove the short after the zero is complete. | msrc_UNKNOWN | Details |
electronic_zero_abort | 4162 | msrc_UNKNOWN | Details | ||
perform_system_zero_method | 40FF | Perform Zero | After ensuring that there is no material flow through the transducer, press ENTER to perform a system zero. | msrc_UNKNOWN | Details |
system_zero_abort | 4165 | msrc_UNKNOWN | Details | ||
perform_temp_cal_method | 40CC | Perform Cal | Allows the user to re-calibrate the temperature measurement. | msrc_UNKNOWN | Details |
temp_stab_abort | 4169 | msrc_UNKNOWN | Details | ||
perform_density_cal_method | 40CE | Perform Cal | To do a Density calibration the user inputs the air frequency and the air temperature from the transducer and the density of the material in the transducer. | msrc_UNKNOWN | Details |
dens_stab_cal_abort | 416A | msrc_UNKNOWN | Details | ||
dens_cal_abort | 416C | msrc_UNKNOWN | Details | ||
perform_dump_cal_method | 40D0 | Perform Dump Cal | To perform a Dump Calibration the user will start and stop the material flow manually and enter the correct test mass quantity for the calibration standard when prompted. | msrc_UNKNOWN | Details |
mass_dump_cal_abort | 416E | msrc_UNKNOWN | Details | ||
perform_batch_cal_method | 40D1 | Perform Batch Cal | To perform a Batch Calibration the user will enter the desired test mass quantity when prompted, start and stop the material flow using the NexGen's batch controller ,and enter the correct test mass quantity from the calibration standard when prompted. | msrc_UNKNOWN | Details |
mass_batch_cal_abort | 4173 | msrc_UNKNOWN | Details | ||
analog1_trim_method | 4106 | Perform Cal | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
leave_cal_fixed_current1_method | 4174 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the selected Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output then tracks the input | msrc_UNKNOWN | Details |
analog2_trim_method | 4108 | Perform Cal | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
leave_cal_fixed_current2_method | 4177 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the selected Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output then tracks the input | msrc_UNKNOWN | Details |
analog4_trim_method | 410A | Perform Cal | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
leave_cal_fixed_current4_method | 4178 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the selected Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output then tracks the input | msrc_UNKNOWN | Details |
self_test_method | 40B7 | Self Test | Instructs transmitter to perform internal self test. | msrc_UNKNOWN | Details |
alarm1_test_method | 40D5 | Alarm 1 Test | Pressing the ENTER key will toggle the Alarm 1 output open and closed. | msrc_UNKNOWN | Details |
alarm1_test_abort_method | 417D | msrc_UNKNOWN | Details | ||
alarm2_test_method | 40D6 | Alarm 2 Test | Pressing the ENTER key will toggle the Alarm 2 output open and closed. | msrc_UNKNOWN | Details |
alarm2_test_abort_method | 417E | msrc_UNKNOWN | Details | ||
batch_hf_method | 40D7 | Batch 1 HF Test | Pressing the ENTER key will toggle the HF Batch output open and closed. | msrc_UNKNOWN | Details |
batch_hf_test_abort_method | 417F | msrc_UNKNOWN | Details | ||
batch_lf_method | 40D8 | Batch 2 LF Test | Pressing the ENTER key will toggle the LF Batch output open and closed. | msrc_UNKNOWN | Details |
batch_lf_test_abort_method | 4180 | msrc_UNKNOWN | Details | ||
analog1_test_method | 40D9 | Analog 1 Test | Fix Analog Output- Allows the User to manually manipulate a selected Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
leave_analog_fixed_current1_method | 4181 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the selected Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output then tracks the input | msrc_UNKNOWN | Details |
analog2_test_method | 40DA | Analog 2 Test | Fix Analog Output- Allows the User to manually manipulate a selected Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
leave_analog_fixed_current2_method | 4182 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the selected Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output then tracks the input | msrc_UNKNOWN | Details |
analog4_test_method | 40DB | Analog 4 Test | Fix Analog Output- Allows the User to manually manipulate a selected Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
leave_analog_fixed_current4_method | 4183 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the selected Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output then tracks the input | msrc_UNKNOWN | Details |
pulse_test_method | 40BB | Pulse Test | Allows the operator to test the pulse output and remote counter by programming the output frequency and the number of pulses required. | msrc_UNKNOWN | Details |
pulse_test_abort_method | 4185 | msrc_UNKNOWN | Details | ||
tube_drive_test_method | 40BC | Tube Drive Test | The tube drive test provides a method for the user to judge the performance of the NexGen's tube drive system. The drive current and sensor voltages are displayed with the calculated drive efficiency. | msrc_UNKNOWN | Details |
tube_test_abort_method | 4187 | msrc_UNKNOWN | Details | ||
alarm1_config_method | 40E3 | Alarm 1 | msrc_UNKNOWN | Details | |
alarm1_config_abort_method | 418B | msrc_UNKNOWN | Details | ||
alarm2_config_method | 40E4 | Alarm 2 | msrc_UNKNOWN | Details | |
alarm2_config_abort_method | 418C | msrc_UNKNOWN | Details | ||
percent_conc_table_method | 4126 | Percent Conc Table | TBD by NEXGEN | msrc_UNKNOWN | Details |
reset_all_total_method | 40F2 | Reset All | Pressing ENTER will reset to 0.0 all mass and volume totalizers | msrc_UNKNOWN | Details |
reset_ind_total_method | 40F3 | Reset Individual | From this menu the user can select and reset to 0.0 any of the mass or volume totalizers. | msrc_UNKNOWN | Details |
sensor_cal_method | 412C | Perform Cal | The menu can be used to view the tube vibration amplitude in mV and to adjust the vibration amplitude setpoint if required. | msrc_UNKNOWN | Details |
set_date_method | 40C5 | Set Date | Allows the user to set the date of the NexGen's real-time clock (MM/DD/YY format). | msrc_UNKNOWN | Details |
set_time_method | 40C6 | Set Time | Allows the user to set the time on the NexGen's real-time clock (HH:MM:SS). | msrc_UNKNOWN | Details |
display_time_method | 40C7 | Display Time/Date | Displays the Date and Time (MM/DD/YY HH:MM:SS format). | msrc_UNKNOWN | Details |
date_time_abort_method | 4196 | msrc_UNKNOWN | Details | ||
change_password_method | 40FA | Change Password | Allows the user too change the unit's password. | msrc_UNKNOWN | Details |
view_password_method | 40FB | View Password | Allows the user to view the next lower level password | msrc_UNKNOWN | Details |
abort_send | 4197 | msrc_UNKNOWN | Details | ||
must_send_pv | 4001 | msrc_UNKNOWN | Details | ||
must_send_sv | 4003 | msrc_UNKNOWN | Details | ||
must_send_tv | 4005 | msrc_UNKNOWN | Details | ||
must_send_qv | 4007 | msrc_UNKNOWN | Details | ||
must_send_units | 4198 | msrc_UNKNOWN | Details | ||
loop_test | 1002 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
dac_trim | 1004 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
scaled_dac_trim | 1005 | Scaled D/A trim | Digital to Analog Scaled Trim- Allows the calibration of the Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
zero_trim | 1006 | Zero trim | Zero trim- Make the sensor input the new zero input reference | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
applied_rerange | 1007 | Apply values | Applied values- Perform a device rerange by applying the desired Upper Range Value and Lower Range Values to the device input | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
fixed_analog_output | 1008 | Fix analog output | Fix Analog Output- Allows the User to manually manipulate a selected Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
tv_zero_trim | 100B | Dev var zero trim | Zero trim- Make the sensor input the new zero input reference | msrc_UNKNOWN | Details |
leave_analog_fixed_current_mode | 1009 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the selected Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output then tracks the input | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |