Method Name: alarm2_config_method
Method ID: 0x40E4
Method Label: Alarm 2
Method Help:
- {
- char status[3];
- char disp_string1[60];
- int slen1;
- int retry;
- int local_var;
- long var_id[5];
- _set_xmtr_device_status(0xFF,0);
- _set_xmtr_all_resp_code(0);
- _set_device_status(0xFF,0);
- _set_all_resp_code(0);
- slen1 = 60;
- var_id[0] = 16715;
- var_id[1] = 16728;
- _iassign(16721,6);
- send_command(160);
- _iassign(16733,44);
- send_command(185);
- if (status[0] == 7)
- {
- display_response_status(185,status[0]);
- DELAY(2,literal_string(566));
- process_abort();
- }
- _add_abort_method(16780);
- do {
- retry = 0;
- _get_dev_var_value(literal_string(342),0,16715);
- send(161,status);
- if (status[0] == 2)
- {
- display_response_status(161,status[0]);
- retry = 1;
- }
Please login for more