Loading…

Method Name: analog4_trim_method

Method ID: 0x410A

Method Label: Perform Cal

Method Help: Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output


  • {
  • char status[3];
  • long var_id[2];
  • _set_xmtr_device_status(0xFF,0);
  • _set_xmtr_all_resp_code(0);
  • _set_device_status(0xFF,0);
  • _set_all_resp_code(0);
  • ACKNOWLEDGE(literal_string(571));
  • ACKNOWLEDGE(literal_string(598));
  • _iassign(4068,4);
  • _fassign(resolve_record_ref(resolve_array_ref(172,4),193),4.0);
  • var_id[0] = resolve_record_ref(resolve_array_ref(172,4),193);