Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
self_test | 402E | Self test | Self-test - Transmitter self-test in progress. The analog output is frozen. Recognised failures are displayed. | msrc_UNKNOWN | Details |
master_test | 402F | Transmitter reset | Transmitter reset - The transmitter is restarted. Non-permanent stored data are lost. Self-test is subsequently conducted. | msrc_UNKNOWN | Details |
wire_trim | 4030 | Lead balancing | Lead balancing - The resistance of the connection lines to sensor can be compensated for. This step is only necessary for measurement resistors in 2-wire circuitry. | msrc_UNKNOWN | Details |
reset_parameter | 4031 | Data reset | Data reset - All data, which were not made permanent are reset to their original values. This allows the old data to be restored when a parameter setting is interrupted. | msrc_UNKNOWN | Details |
configure_sensor | 4036 | Sensor config. | Input parameter - the parameters for wiring to the input (sensor type, etc.) can be fixed via the function. | msrc_UNKNOWN | Details |
select_unit | 4037 | Process unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | msrc_UNKNOWN | Details |
test_range | 4038 | Aborting return to normal | msrc_UNKNOWN | Details | |
configure_output | 403B | Output config. | Configuration of analog output - The setting determines the behaviour of the output in case of failure. | msrc_UNKNOWN | Details |
send_data | 403C | Send data | msrc_UNKNOWN | Details | |
edit_curve | 4082 | Tiepoints | Tiepoints - review and edit the linearisation characteristics of the Free style sensortype. | msrc_UNKNOWN | Details |
input_trim | 408B | A/D trim | Analog to Digital trim - Allows the calibration of a selected Analog Input with an external reference ( precision calibrator ). | msrc_UNKNOWN | Details |
preset_all | 408C | Factory preset | Factory preset - All calibration data are overwritten with the basic data fixed during manufacture. The parameter data are reset to the standard values. CAUTION: The user data are thus lost permanently. | msrc_UNKNOWN | Details |
preset_all_abort | 408D | preset_all_abort | msrc_UNKNOWN | Details | |
preset_mfgtrim | 408E | Reset trimmings | Reset trimmings - All calibration data are overwritten with the basic data fixed during manufacture. The parameter data is unchanged. | msrc_UNKNOWN | Details |
loop_test | 1002 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
dac_trim | 1004 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
scaled_dac_trim | 1005 | Scaled D/A trim | Digital to Analog Scaled Trim- Allows the calibration of the Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
applied_rerange | 1007 | Apply values | Applied values- Perform a device rerange by applying the desired Upper Range Value and Lower Range Values to the device input | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
burn_eeprom | 100C | Masterizza EEPROM | Burn Electrically Erasable Read Only Memory- Operation where the Field Device will copy what is in its Random Access Memory into the Electrically Erasable Read Only Memory, thus making changes by the Host permanent | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |