Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
LF220_self_test | 4058 | Self test | msrc_UNKNOWN | Details | |
LF220_press_keypad_pre_warning | 4059 | ループをマニュアルにします | msrc_UNKNOWN | Details | |
LF220_press_keypad_post_warning | 405A | NOTE - ループをオート コントロールに戻して下さい | msrc_UNKNOWN | Details | |
static_flow_zero | 405B | EMF zero | EMF zero- Make zero-point adjustment, with the fluid within the measuring pipe of the detector completely at a halt. | msrc_UNKNOWN | Details |
LF220_sensor_trim | 405C | Calibration | msrc_UNKNOWN | Details | |
flow_cal_0 | 4099 | FLOW CAL 0% | PV% display- PV% is displayed every 1 second. Calibration start- 0% calibration start. Exit- Exit and back to menu. | msrc_UNKNOWN | Details |
flow_cal_50 | 40C1 | FLOW CAL 50% | PV% display- PV% is displayed every 1 second. Calibration start- 50% calibration start. Exit- Exit and back to menu. | msrc_UNKNOWN | Details |
flow_cal_100 | 409A | FLOW CAL 100% | PV% display- PV% is displayed every 1 second. Calibration start- 100% calibration start. Exit- Exit and back to menu. | msrc_UNKNOWN | Details |
ex_curr_dsp | 409B | EX.CURR.DSP. | msrc_UNKNOWN | Details | |
LF220_count_rate | 409D | Count rate | Count rate- For the integral counter, the amount per count (pulse or count rate) is set. | msrc_UNKNOWN | Details |
LF220_multi_range_hysteresys | 405D | Hysteresys | Hysteresys- Set the blind sector width associated with range switching. | msrc_UNKNOWN | Details |
LF220_manual_zero | 40C2 | Manual zero | Manual Zero- Manual Zero value is setting for zero offset value that can be applied to make outputs comparable to process values measured by other instruments. | msrc_UNKNOWN | Details |
LF220_fixed_pulse | 409E | Fixed pulse | Fixed pulse. | msrc_UNKNOWN | Details |
LF220_pass_word | 40C3 | Password | Password- Security code for local programing. Enter correct password by local SW, enable parameters to change. | msrc_UNKNOWN | Details |
LF220_alarm_set | 40C4 | Alarm set (ON/OFF) | Alarm setting | msrc_UNKNOWN | Details |
LF220_D_size | 405E | Meter size | Meter size- Detector Inlet Diameter. | msrc_UNKNOWN | Details |
limit_of_change | 405F | Limit of change | Limit of change- The change rate limitation provides the function for suppressing sudden variations in converter flow rate signal output generated when too much noise is contained in the flow rate signal. | msrc_UNKNOWN | Details |
main_unit | 40C5 | UNIT1 | Display UNIT1- Engineering unit on unit1 LCD of converter to be display with flow values. | msrc_UNKNOWN | Details |
sub_unit | 40C6 | UNIT2 | Display UNIT2- Engineering unit on unit2 LCD of converter to be display with flow values. | msrc_UNKNOWN | Details |
LF220_flange_types | 409C | Flange type | msrc_UNKNOWN | Details | |
pulse_width | 4060 | Pulse width | msrc_UNKNOWN | Details | |
preset_counter | 4061 | Preset count | Preset count- Preset value of preset counter is set. | msrc_UNKNOWN | Details |
alarm_upper_value | 4062 | High alarm | High alarm value- Flow-rate high limit alarm value. | msrc_UNKNOWN | Details |
alarm_lower_value | 4063 | Low alarm | Low alarm- Flow-rate low limit alarm value. | msrc_UNKNOWN | Details |
review2_method | 4064 | Review2 | msrc_UNKNOWN | Details | |
loop_test | 1002 | ループ テスト | ループ テスト - アナログ出力をユーザーが選択した値で固定出力します | msrc_UNKNOWN | Details |
return_to_normal | 1016 | ノーマル モードに戻します | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | 固定電流モードを終ります | 現在の固定モードを終了 - アナログ出力を定数値のモードから移行させ, 出力が入力に応じて変わるモードに戻します。 | msrc_UNKNOWN | Details |
dac_trim | 1004 | D/A トリム | D/A トリム (デジタル/アナログ トリム) - オペレーティング エンド ポイントに対するアナログ出力と外部指示計とのキャリブレーションを行います。 | msrc_UNKNOWN | Details |