Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
transmitter_dac_trim | 1024 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
SimulatePV | 4001 | Simulate Device Variable | Forces the Value of Variable and its Status to Specified Value (Fixed) or Exits this Mode (Manual). Also Exits after Device Reboot. | msrc_UNKNOWN | Details |
applied_rerange | 1007 | Apply values | Applied values- Perform a device rerange by applying the desired Upper Range Value and Lower Range Values to the device input | msrc_UNKNOWN | Details |
device_variable_trim_reset | 1083 | Device variable trim reset | Reset trim variabile dispositivo - Consente di impostare la variabile dispositivo sul suo trim di fabbrica predefinito. | msrc_UNKNOWN | Details |
trim_warning | 1081 | Trim warning | msrc_UNKNOWN | Details | |
device_variable_trim | 1080 | Device variable trim | Trim variabile dispositivo - Consente di regolare linearmente la misura di taratura di una variabile dispositivo. Il punto di trim che viene inviato al dispositivo deve rappresentare il valore della variabile di processo attualmente applicata. | msrc_UNKNOWN | Details |
zero_trim | 1006 | Zero trim | Zero trim- Make the sensor input the new zero input reference | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | msrc_UNKNOWN | Details | ||
transmitter_loop_test | 1023 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
ResetConfigurationChangedFlag | 4003 | Rst Cnf Cng Flag | Reset configuration changed flag. | msrc_UNKNOWN | Details |
RestoreFactParams | 4004 | Restore factory parameters | Reset Field Device configuration parameters to factory values. | msrc_UNKNOWN | Details |
UpdateParams | 4006 | Reread params | Reread parameters values. | msrc_UNKNOWN | Details |
ChangeWriteProtectMode | 4007 | Write protect | Enables or Disables HART Write Protection. | msrc_UNKNOWN | Details |
ChangeHARTpass | 4008 | Change password | Changes HART Password used to disable Write Protection, to reset peak values and to enter local menu using buttons. Default Factory value is 0000 | msrc_UNKNOWN | Details |
RereadValues | 400A | Reread values | Reread values. | msrc_UNKNOWN | Details |
ResetUserValues | 400B | Reset user values | Resets peak detector user values. | msrc_UNKNOWN | Details |
device_master_reset | 1072 | Device reset | Reset dispositivo - Fornisce un comando all’elettronica affinché esegua un reset Questo equivale a spegnere e riaccendere il dispositivo di campo. | msrc_UNKNOWN | Details |
makeItSquawk | 101B | Squawk | Make the Field Device Squawk - This causes the device to visually, audibly or mechanically alert to allow technicans to idendify it | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |