Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
transmitter_dac_trim | 1024 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
SimulatePV | 4001 | Simulate Device Variable | Forces the Value of Variable and its Status to Specified Value (Fixed) or Exits this Mode (Manual). Also Exits after Device Reboot. | msrc_UNKNOWN | Details |
applied_rerange | 1007 | Apply values | Applied values- Perform a device rerange by applying the desired Upper Range Value and Lower Range Values to the device input | msrc_UNKNOWN | Details |
device_variable_trim_reset | 1083 | Device variable trim reset | Restablecimiento de ajuste de variable de dispositivo: Permite que la variable de dispositivo se establezca en su ajuste de fábrica predeterminado. | msrc_UNKNOWN | Details |
trim_warning | 1081 | Trim warning | msrc_UNKNOWN | Details | |
device_variable_trim | 1080 | Device variable trim | Ajuste de variable de dispositivo: Permite que la medida de calibración de una variable de dispositivo se ajuste linealmente. El punto de ajuste que se envía al dispositivo debe representar el valor de variable del proceso aplicado actualmente. | msrc_UNKNOWN | Details |
zero_trim | 1006 | Zero trim | Zero trim- Make the sensor input the new zero input reference | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | msrc_UNKNOWN | Details | ||
transmitter_loop_test | 1023 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
ResetConfigurationChangedFlag | 4003 | Rst Cnf Cng Flag | Reset configuration changed flag. | msrc_UNKNOWN | Details |
RestoreFactParams | 4004 | Restore factory parameters | Reset Field Device configuration parameters to factory values. | msrc_UNKNOWN | Details |
UpdateParams | 4006 | Reread params | Reread parameters values. | msrc_UNKNOWN | Details |
ChangeWriteProtectMode | 4007 | Write protect | Enables or Disables HART Write Protection. | msrc_UNKNOWN | Details |
ChangeHARTpass | 4008 | Change password | Changes HART Password used to disable Write Protection, to reset peak values and to enter local menu using buttons. Default Factory value is 0000 | msrc_UNKNOWN | Details |
RereadValues | 400A | Reread values | Reread values. | msrc_UNKNOWN | Details |
ResetUserValues | 400B | Reset user values | Resets peak detector user values. | msrc_UNKNOWN | Details |
device_master_reset | 1072 | Device reset | Reinicio del dispositivo: Ordena a la electrónica a que realice un reinicio. Esto equivale a apagar la alimentación del dispositivo de campo y luego volver a encenderla. | msrc_UNKNOWN | Details |
makeItSquawk | 101B | Squawk | Make the Field Device Squawk - This causes the device to visually, audibly or mechanically alert to allow technicans to idendify it | msrc_UNKNOWN | Details |