名称 | ID | 标签 | 描述 | 类型 | 源代码 |
---|---|---|---|---|---|
go_to_setup_mode_method | 4037 | msrc_UNKNOWN | 详细信息 | ||
set_manual_method | 403A | -> MANUAL MODE | To allow others menus, this function set the SVI II in manual mode. | msrc_UNKNOWN | 详细信息 |
air_acting_method | 403C | Actuator info | Change actuator ATO or ATC acting. | msrc_UNKNOWN | 详细信息 |
find_stop_method | 403D | Calibrate travel | Run auto find stop. | msrc_UNKNOWN | 详细信息 |
autotune_method | 403E | Auto-tune | Run PID Auto tune. | msrc_UNKNOWN | 详细信息 |
factory_configuration_method | 403F | Factory defaults | To reset the SVI II with Factory defaults values. | msrc_UNKNOWN | 详细信息 |
read_status_method | 405E | read status | msrc_UNKNOWN | 详细信息 | |
read_historic_status_method | 405F | historic fault | msrc_UNKNOWN | 详细信息 | |
clear_fault_code_method | 4060 | clear status | Clear all the status coming from communication or device errors | msrc_UNKNOWN | 详细信息 |
read_raw_data_method | 4068 | raw data | msrc_UNKNOWN | 详细信息 | |
burst_mode_method | 406A | burst mode ON/OFF | Burst Option- Selects the variable(s) that will be Bursted if Burst Mode is enabled. Choice of three commands for burst mode : -CMD 1 : read primary variable, -CMD 2 : read current and percentage, -CMD 3 : read current and four variables. Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. | msrc_UNKNOWN | 详细信息 |
manual_setpoint_method | 4035 | change pos <-> | Manual valve setpoint in %. | msrc_UNKNOWN | 详细信息 |
go_to_manual_mode_method | 408D | MANUAL MODE --> | msrc_UNKNOWN | 详细信息 | |
return_to_normal_mode_method | 408E | NORMAL MODE --> | msrc_UNKNOWN | 详细信息 | |
tag_method | 403B | tag | Change tag, descriptor, message etc...reported by the SVI II. | msrc_UNKNOWN | 详细信息 |
options_method | 4092 | options | Change options in config menu reported by the SVI II like valve characterization , button lock , limit stops and other options. | msrc_UNKNOWN | 详细信息 |
setup_method | 4093 | setup | Change setup in config menu reported by the SVI II like actuator ATO or ATC, Position fault limits ... | msrc_UNKNOWN | 详细信息 |
range_method | 4099 | range | Selects the range sub dialog where the user can enter the upper and lower scale values for the input signal.The values typically are 4 and 20 mA but may be any values between 3.8 and 22 mA(Range signal).This dialog also allows auto find stop, manual stop and open stop adjustment. | msrc_UNKNOWN | 详细信息 |
tuning_method | 409A | tuning | The user can set tuning PID coefficients, run auto tune function and set I/P output. | msrc_UNKNOWN | 详细信息 |
calib_signal_method | 409B | signal calibrate | To calibrate or to check the 4-20mA current. To calibrate or to check the pressure sensor if any, to return to factory setting. | msrc_UNKNOWN | 详细信息 |
perform_standard_method | 40A0 | perform standard | Perform valve signature and valve fonctional analysis. Displays the standard diagnostic test results. | msrc_UNKNOWN | 详细信息 |
diagnos_display_method | 40A1 | read diagnostic | Displays CONTINUOUS DIAGNOSTIC DATA including number of full strokes the valve has made,the number of cycles (direction changes),the time the valve has spent open, the time the valve has been closed and the time the valve has spent throttling near the seat. | msrc_UNKNOWN | 详细信息 |
reset_continuous_method | 40A2 | reset continuous | Reset continuous diagnostic data (stroke count,cycle count, time open, time closed and time near closed ) to 0.The previous data are lost and must be recorded to be used later. | msrc_UNKNOWN | 详细信息 |
reset_method | 405D | SVI II RESET | This function perform a master reset to the device, causing it to go through its startup routine and re-initializing all of its operating parameters from non volatile memory. | msrc_UNKNOWN | 详细信息 |
before_return_to_normal_method | 409D | special return to normal | msrc_UNKNOWN | 详细信息 | |
interrupt_process_method | 4041 | stop procedure | msrc_UNKNOWN | 详细信息 | |
return_to_manual_mode_method | 4038 | return to manual | msrc_UNKNOWN | 详细信息 | |
Bumpless_method | 40AC | Bumpless | Time to move the valve until the position matches the input current.Range 0 to 255 s. | msrc_UNKNOWN | 详细信息 |
cam_method | 40AD | cam | cam used in the SVI II:relationship between flow capacity (Cv) and percentage opening of the valve.Several cams are available:linear/=%50/=%30/quick opening coeff 50/custom. | msrc_UNKNOWN | 详细信息 |
limit_method | 40AE | limits | msrc_UNKNOWN | 详细信息 | |
read_switches_state_method | 40D2 | msrc_UNKNOWN | 详细信息 | ||
Find_Firmware_Revision_method | 40D5 | msrc_UNKNOWN | 详细信息 | ||