Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
go_to_setup_mode_method | 4037 | msrc_UNKNOWN | Details | ||
set_manual_method | 403A | -> MANUAL MODE | To allow others menus, this function set the SVI II in manual mode. | msrc_UNKNOWN | Details |
air_acting_method | 403C | Actuator info | Change actuator ATO or ATC acting. | msrc_UNKNOWN | Details |
find_stop_method | 403D | Calibrate travel | Run auto find stop. | msrc_UNKNOWN | Details |
autotune_method | 403E | Auto-tune | Run PID Auto tune. | msrc_UNKNOWN | Details |
factory_configuration_method | 403F | Factory defaults | To reset the SVI II with Factory defaults values. | msrc_UNKNOWN | Details |
read_status_method | 405E | read status | msrc_UNKNOWN | Details | |
read_historic_status_method | 405F | historic fault | msrc_UNKNOWN | Details | |
clear_fault_code_method | 4060 | clear status | Clear all the status coming from communication or device errors | msrc_UNKNOWN | Details |
read_raw_data_method | 4068 | raw data | msrc_UNKNOWN | Details | |
burst_mode_method | 406A | burst mode ON/OFF | Burst Option- Selects the variable(s) that will be Bursted if Burst Mode is enabled. Choice of three commands for burst mode : -CMD 1 : read primary variable, -CMD 2 : read current and percentage, -CMD 3 : read current and four variables. Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. | msrc_UNKNOWN | Details |
manual_setpoint_method | 4035 | change pos <-> | Manual valve setpoint in %. | msrc_UNKNOWN | Details |
go_to_manual_mode_method | 408D | MANUAL MODE --> | msrc_UNKNOWN | Details | |
return_to_normal_mode_method | 408E | NORMAL MODE --> | msrc_UNKNOWN | Details | |
tag_method | 403B | tag | Change tag, descriptor, message etc...reported by the SVI II. | msrc_UNKNOWN | Details |
options_method | 4092 | options | Change options in config menu reported by the SVI II like valve characterization , button lock , limit stops and other options. | msrc_UNKNOWN | Details |
setup_method | 4093 | setup | Change setup in config menu reported by the SVI II like actuator ATO or ATC, Position fault limits ... | msrc_UNKNOWN | Details |
range_method | 4099 | range | Selects the range sub dialog where the user can enter the upper and lower scale values for the input signal.The values typically are 4 and 20 mA but may be any values between 3.8 and 22 mA(Range signal).This dialog also allows auto find stop, manual stop and open stop adjustment. | msrc_UNKNOWN | Details |
tuning_method | 409A | tuning | The user can set tuning PID coefficients, run auto tune function and set I/P output. | msrc_UNKNOWN | Details |
calib_signal_method | 409B | signal calibrate | To calibrate or to check the 4-20mA current. To calibrate or to check the pressure sensor if any, to return to factory setting. | msrc_UNKNOWN | Details |
perform_standard_method | 40A0 | perform standard | Perform valve signature and valve fonctional analysis. Displays the standard diagnostic test results. | msrc_UNKNOWN | Details |
diagnos_display_method | 40A1 | read diagnostic | Displays CONTINUOUS DIAGNOSTIC DATA including number of full strokes the valve has made,the number of cycles (direction changes),the time the valve has spent open, the time the valve has been closed and the time the valve has spent throttling near the seat. | msrc_UNKNOWN | Details |
reset_continuous_method | 40A2 | reset continuous | Reset continuous diagnostic data (stroke count,cycle count, time open, time closed and time near closed ) to 0.The previous data are lost and must be recorded to be used later. | msrc_UNKNOWN | Details |
reset_method | 405D | SVI II RESET | This function perform a master reset to the device, causing it to go through its startup routine and re-initializing all of its operating parameters from non volatile memory. | msrc_UNKNOWN | Details |
before_return_to_normal_method | 409D | special return to normal | msrc_UNKNOWN | Details | |
interrupt_process_method | 4041 | stop procedure | msrc_UNKNOWN | Details | |
return_to_manual_mode_method | 4038 | return to manual | msrc_UNKNOWN | Details | |
Bumpless_method | 40AC | Bumpless | Time to move the valve until the position matches the input current.Range 0 to 255 s. | msrc_UNKNOWN | Details |
cam_method | 40AD | cam | cam used in the SVI II:relationship between flow capacity (Cv) and percentage opening of the valve.Several cams are available:linear/=%50/=%30/quick opening coeff 50/custom. | msrc_UNKNOWN | Details |
limit_method | 40AE | limits | msrc_UNKNOWN | Details | |
read_switches_state_method | 40D2 | msrc_UNKNOWN | Details | ||
Find_Firmware_Revision_method | 40D5 | msrc_UNKNOWN | Details | ||
Name | ID | Label | Description | Type | Source |