Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
show_calibration_points_method | 4081 | Show Cal.Curve | Shows Calibration Curve | msrc_UNKNOWN | Details |
do_calibration_method | 4082 | Sort&Check Curve | Sort&Check Calibration Curve | msrc_UNKNOWN | Details |
enter_cal_point_method | 4083 | Enter Cal.Pt. | Enter Calibration Point | msrc_UNKNOWN | Details |
enter_background_method | 4084 | Set Background | It is important to measure the background when the probe is a rod detector. The background is the natural radiation only. The background must be measured, when the source is not yet installed on the vessel. | msrc_UNKNOWN | Details |
enter_adjust_lower_cal_point_method | 4085 | Adjust Lo.Cal.Pt. | Adjusts Lower Calibration Point | msrc_UNKNOWN | Details |
enter_adjust_upper_cal_point_method | 4086 | Adjust Up.Cal.Pt. | Adjusts Upper Calibration Point | msrc_UNKNOWN | Details |
error_log_method | 4087 | Show Error Log | Shows the last occured errors. | msrc_UNKNOWN | Details |
change_password_method | 4088 | Change Password | This is a availability to set up max. 3 password levels. The password for the full access level includes the access to configuration and calibration too. Each password can be different or equal to another password. Password for access Read Only can't be changed. | msrc_UNKNOWN | Details |
enter_password_method | 4089 | Enter Access Password | In order to get access to other level, the right password must be entered. | msrc_UNKNOWN | Details |
abort_restore_factory_setting_method | 40EC | msrc_UNKNOWN | Details | ||
restore_factory_settings_method | 408A | Factory Settings | Factory Reset will delete all settings and restore the factory default values. | msrc_UNKNOWN | Details |
save_cal_curve_as_basic_curve_method | 408B | Save | Save the current calibration curve in a separate register. E.g. a Basic Calibration Curve. | msrc_UNKNOWN | Details |
load_basic_curve_method | 408C | Load | Load a previous stored calibration curve, and overwrite the current one. | msrc_UNKNOWN | Details |
sensor_reset_method | 40CF | Hardware Reset | Hardware Reset will restart the CPU without loosing data. | msrc_UNKNOWN | Details |
pre_edit_digital_output_method | 40D0 | msrc_UNKNOWN | Details | ||
post_edit_digital_output_method | 40D1 | msrc_UNKNOWN | Details | ||
digital_output_test_method | 40ED | Dig.Output Test | Runs Digital Output Test | msrc_UNKNOWN | Details |
plateau_measurement_method | 40D2 | Measure Plateau | Runs Plateau measurement | msrc_UNKNOWN | Details |
show_plateau_points_method | 40D3 | Show Plateau | Shows Plateau Points | msrc_UNKNOWN | Details |
show_operating_mode_method | 40EE | Show Op.Mode | Shows Operation Mode | msrc_UNKNOWN | Details |
refresh_dig_out_parameter_method | 40DA | Updating......... | msrc_UNKNOWN | Details | |
write_and_refresh_dig_out_parameter_method | 40DB | Updating......... | msrc_UNKNOWN | Details | |
refresh_dig_in_parameter_method | 40DD | Updating......... | msrc_UNKNOWN | Details | |
write_and_refresh_dig_in_parameter_method | 40EF | Updating......... | msrc_UNKNOWN | Details | |
refresh_var_loop_current_error_method | 40D7 | Updating......... | msrc_UNKNOWN | Details | |
refresh_var_damping_mode_method | 40D9 | Updating......... | msrc_UNKNOWN | Details | |
refresh_var_interference_detect_ctrl_method | 40DF | Updating......... | msrc_UNKNOWN | Details | |
refresh_var_level_units_method | 40D6 | Updating......... | msrc_UNKNOWN | Details | |
write_and_refresh_var_detector_hv_ctrl_method | 40D8 | Updating......... | msrc_UNKNOWN | Details | |
loop_test | 1002 | ループ テスト | ループ テスト - アナログ出力をユーザーが選択した値で固定出力します | msrc_UNKNOWN | Details |
dac_trim | 1004 | D/A トリム | D/A トリム (デジタル/アナログ トリム) - オペレーティング エンド ポイントに対するアナログ出力と外部指示計とのキャリブレーションを行います。 | msrc_UNKNOWN | Details |
return_to_normal | 1016 | ノーマル モードに戻します | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | 固定電流モードを終ります | 現在の固定モードを終了 - アナログ出力を定数値のモードから移行させ, 出力が入力に応じて変わるモードに戻します。 | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |