名称 | ID | 标签 | 描述 | 类型 | 源代码 |
---|---|---|---|---|---|
correct_inp_lrv_method | 4066 | Input LRV Calibration | Input LRV Calibration- Calibrates the zero point (Lower Range Value) based on the current input value. | msrc_UNKNOWN | 详细信息 |
correct_inp_urv_method | 4067 | Input URV Calibration | Input URV Calibration- Calibrates the span (Upper Range Value) based on the current input value. | msrc_UNKNOWN | 详细信息 |
reset_correct_method | 4068 | Reset Calibration | Reset Calibration- Discards calibration data. | msrc_UNKNOWN | 详细信息 |
set_lrv_actual_method | 4065 | Set LRV (Actual) | Set LRV (Actual)- Sets the Lower Range Value at the present output value. | msrc_UNKNOWN | 详细信息 |
cutoff_mode_method | 4062 | Change Cutoff Mode | Change Cutoff Mode- Selects the cutoff mode and sets the cutoff point. Valid when Square Root is selected for Transfer Function. | msrc_UNKNOWN | 详细信息 |
clear_status_record_method | 4058 | Clear Status Records | Clear status records- Clears the device's Status Record. | msrc_UNKNOWN | 详细信息 |
write_protect_method | 279B | Change SW Write Protect | Change Software Write Protect- Can be set to 'Yes' or 'No'. | msrc_UNKNOWN | 详细信息 |
applied_zero_method | 4063 | Apply Zero Value | Apply zero value- Sets the Lower Range Value at the present input pressure. | msrc_UNKNOWN | 详细信息 |
applied_span_method | 4064 | Apply Span Value | Apply span value- Sets the Upper Range Value at the present input pressure. | msrc_UNKNOWN | 详细信息 |
restore_factory_setting_method | 4069 | Restore Factory Setting | Restore factory settings- Return to the factory default calibration data. | msrc_UNKNOWN | 详细信息 |
open_contact_output_method | 406A | Open | Open- Simulates the contact output. Select [Open] to put the device in simulation mode, with contact output circuit is open. | msrc_UNKNOWN | 详细信息 |
closed_contact_output_method | 406B | Closed | Closed- Simulates the contact output. Select [Closed] to put the device in simulation mode, with contact output circuit is closed. | msrc_UNKNOWN | 详细信息 |
clear_contact_output_method | 406C | Clear | Clear- Simulates the contact output. Selects [Clear] to cancel simulation mode. | msrc_UNKNOWN | 详细信息 |
read_sw_version_method | 4041 | Software Version | Software Version- Displays the software version of device. | msrc_UNKNOWN | 详细信息 |
scaled_dac_trim_method | 4198 | Scaled D/A Trim | 数字到模拟缩放修正——允许对选择的模拟量输出进行标定,在模拟量输出的操作端点有外部参考。 | msrc_UNKNOWN | 详细信息 |
burnout_simulation_method | 40B9 | Failure Alarm Simulation Mode | Failure Alarm Simulation Mode- Simulates the output when the device is in a critical state. | msrc_UNKNOWN | 详细信息 |
burnout_simulation_clear_method | 40BD | Clear | Clear- Simulates the output when the device is in a critical state. Select [Clear] to cancel simulation mode. | msrc_UNKNOWN | 详细信息 |
amb_temp_compensate_method | 4154 | Amb. Temp. Compensate | Ambient Temperature Compensation- Compensates for the effects of temperature on the fill fluid. The user must enter the flange span and fill fluid type. | msrc_UNKNOWN | 详细信息 |
auto_range_method | 4155 | Auto Range (Closed Tank) | Auto Range (closed tank)- Automatically calculates the range (LRV and URV). The user must enter the high pressure flange location, specific gravity, fill fluid, span, flange span, and distance of the zero level above the lower flange. This function is valid when Display Function is linear. | msrc_UNKNOWN | 详细信息 |
contact_output_simulation_method | 4160 | Contact Output Simulation Mode | Contact Output Simulation Mode- Simulates the contact output. --Open: Select [Open] to put the device in simulation mode with the contact output circuit open. --Closed: Select [Closed] to put the device in simulation mode with the contact output circuit closed. | msrc_UNKNOWN | 详细信息 |
reset_press_freq_index_all_method | 4170 | Reset Press Freq Index | Reset Press Freq Index- Resets the Pressure Frequency Index and the Press Freq Index Max and Min values. | msrc_UNKNOWN | 详细信息 |
reset_standard_deviation_method | 4172 | Reset Standard Deviation | Reset Standard Deviation- Resets the Standard Deviation, the Standard Deviation Max and Min values, and the Average Pressure. | msrc_UNKNOWN | 详细信息 |
reset_overload_count_method | 4174 | Reset OOR Pressure Count | Reset OOR Pressure Count- Resets the Out-of-Range Pressure Count. | msrc_UNKNOWN | 详细信息 |
self_test_method | 4169 | Status | Status- Displays the result of self-diagnosis of the device. | msrc_UNKNOWN | 详细信息 |
std_dev_chart_disp_method | 41B2 | msrc_UNKNOWN | 详细信息 | ||
overload_cnt_chart_disp_method | 41B3 | msrc_UNKNOWN | 详细信息 | ||
change_press_freq_idx_sensor_select_method | 4171 | Change Press Freq Index Sensor Selection | Change Press Freq Index Sensor Selection- This function changes the Press Freq Index Sensor Selection. If the Press Freq Index Sensor Selection is changed, other parameters (Pressure Frequency Index, Press Freq Index Max, Press Freq Index Min) will be reset. | msrc_UNKNOWN | 详细信息 |
change_standard_deviation_sample_cnt_method | 4173 | Change Standard Deviation Sample Count | Change Standard Deviation Sample Count- This function changes the Standard Deviation Sample Count. If the Standard Deviation Sample Count is changed, other parameters (Standard Deviation, Standard Deviation Max, Standard Deviation Min, Average Pressure) will be reset. | msrc_UNKNOWN | 详细信息 |
zero_trim | 1006 | 归零修正 | 归零修正——使传感器输入新归零输入参考。 | msrc_UNKNOWN | 详细信息 |
return_to_normal | 1016 | 中止返回正常 | msrc_UNKNOWN | 详细信息 | |
transmitter_loop_test | 1023 | 回路测试 | 回路测试——允许用户将选择的模拟量输出手动调节至选择的常数输出值。 | msrc_UNKNOWN | 详细信息 |
leave_fixed_current_mode | 1003 | 退出固定电流模式 | 退出固定电流模式——使选择的模拟量输出退出输出为常数值的模式,使输出返回输出跟踪输入的模式。 | msrc_UNKNOWN | 详细信息 |
transmitter_dac_trim | 1024 | D/A修正 | 数字到模拟修正——允许对选择的模拟量输出进行标定,在模拟量输出的操作端点有外部参考。 | msrc_UNKNOWN | 详细信息 |
burn_eeprom | 100C | 烧录EEPROM | 烧录电可擦除只读存储器——现场设备将随机存取存储器中数据复制到电可擦除只读存储器的操作,主机可做修改。 | msrc_UNKNOWN | 详细信息 |
名称 | ID | 标签 | 描述 | 类型 | 源代码 |