Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
correct_inp_lrv_method | 4066 | Correct Input LRV | Correct Input LRV- Calibrates zero point (Lower Range Value) based on the current input value. | msrc_UNKNOWN | Details |
correct_inp_urv_method | 4067 | Correct Input URV | Correct Input URV- Calibrates span (Upper Range Value) based on the current input value. | msrc_UNKNOWN | Details |
reset_correct_method | 4068 | Reset Corrects | Reset Corrects- Discards calibration data. | msrc_UNKNOWN | Details |
set_lrv_actual_method | 4065 | Set LRV(Actual) | Set LRV(Actual)- Sets the Lower Range Value so that the present output value is used as the preset value. | msrc_UNKNOWN | Details |
cutoff_mode_method | 4062 | Change Cutoff Mode | Change Cutoff Mode- Selects the cutoff mode and sets the cutoff point. Valid when Square Root is selected in Transfer Function. | msrc_UNKNOWN | Details |
self_test | 4055 | Status | Status- Displays the result of self-diagnosis of the device. | msrc_UNKNOWN | Details |
clear_status_record_method | 4058 | Clear Status Records | Clear status records- Clears the Status-Record in device. | msrc_UNKNOWN | Details |
write_protect_method | 279B | Change SW Write Protect | Change Software Write Protect- Selects either 'Yes' or 'No'. | msrc_UNKNOWN | Details |
applied_zero_method | 4063 | Apply Zero Value | Apply zero value- Set the Lower Range Value at the input pressure. | msrc_UNKNOWN | Details |
applied_span_method | 4064 | Apply Span Value | Apply span value- Sets the Upper Range Value at the input pressure. | msrc_UNKNOWN | Details |
restore_factory_setting_method | 4069 | Restore Factory Setting | Restore factory setting- Return to the factory default calibration date. | msrc_UNKNOWN | Details |
open_contact_output_method | 406A | Open | Open- Simulates the contact output. Select [Open] to put the device in simulation mode, with contact output circuit is open. | msrc_UNKNOWN | Details |
closed_contact_output_method | 406B | Closed | Closed- Simulates the contact output. Select [Closed] to put the device in simulation mode, with contact output circuit is closed. | msrc_UNKNOWN | Details |
clear_contact_output_method | 406C | Clear | Clear- Simulates the contact output. Selects [Clear] to cancel simulation mode. | msrc_UNKNOWN | Details |
read_sw_version_method | 4041 | Software Version | Software Version- Displays the software version of device. | msrc_UNKNOWN | Details |
scaled_dac_trim | 1005 | Scaled D/A Trim | Digital zu Analog Abgleich- Ermöglicht den Abgleich der Endpunkten des Analogausgangs mit einer externen Referenz | msrc_UNKNOWN | Details |
burnout_simulation_method | 40B9 | Failure Alarm Simulation Mode | Failure Alarm Simulation Mode- Simulates the output when the device is in a critical state. | msrc_UNKNOWN | Details |
burnout_simulation_clear_method | 40BD | Clear | Clear- Simulates the output when the device is in a critical state. Select [Clear] to cancel simulation mode. | msrc_UNKNOWN | Details |
zero_trim | 1006 | Zero Trim | Meßanfangs-Abgleich- Der Meßanfang wird dem aktuellen Sensoreingangswert gleichgestellt | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Abbruch Rückk. zu normal | msrc_UNKNOWN | Details | |
transmitter_loop_test | 1023 | Loop Test | Meßkreistest- ermöglicht es, den Analogausgang manuell auf einen gewünschten konstanten Wert einzustellen | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Fest-Stromausgang beenden | Konstantstrom Modus verlassen- Der Analogausgang war auf einen bestimmten Ausgangswert eingefroren. Es erfolgt die Rückkehr zu der Betriebsart, bei der der Analogausgang wieder dem Prozeßwert folgt | msrc_UNKNOWN | Details |
transmitter_dac_trim | 1024 | D/A Trim | Digital zu Analog Abgleich- Ermöglicht den Abgleich der Endpunkten des gewählten Analogausgangs mit einer externen Referenz | msrc_UNKNOWN | Details |
burn_eeprom | 100C | EEPROM brennen | EEPROM löschen/programmieren- Vorgang bei dem das Feldgerät RAM-Inhalte in den elektrisch löschbaren / programmierbaren ROM kopiert, und somit die Änderungen durch den Host dauerhaft in das Feldgerät speichert | msrc_UNKNOWN | Details |