Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
set_flow_lrv_zero | 4049 | set_flow_lrv_zero | msrc_UNKNOWN | Details | |
sensor_a_lower_sensor_trim | 1787 | Pres lor snsr trim | Pressure Sensor Lower Trim- Calibrate the pressure sensor. | msrc_UNKNOWN | Details |
sensor_a_upper_sensor_trim | 1789 | Pres upr snsr trim | Pressure Sensor Upper Trim- Calibrate the pressure sensor. | msrc_UNKNOWN | Details |
stat_press_lower_sensor_trim | 402A | Stat pres low snsr trim | Pressure Sensor Lower Trim- Calibrate the static pressure sensor. | msrc_UNKNOWN | Details |
stat_press_upper_sensor_trim | 402B | Stat pres upp snsr trim | Pressure Sensor Upper Trim- Calibrate the static pressure sensor. | msrc_UNKNOWN | Details |
leave_trim_mode | 1788 | Exit trim mode | Exit Trim Mode- Notifies the User that the trim is finished. | msrc_UNKNOWN | Details |
self_test | 4017 | Self test | Performs self test on the 2000T. Reports any errors. | msrc_UNKNOWN | Details |
stuck_in_self_test | 4069 | Stuck in self test | msrc_UNKNOWN | Details | |
self_test_end | 406A | Self test OK | msrc_UNKNOWN | Details | |
master_reset | 4018 | Master reset | Resets the 2000T electronic | msrc_UNKNOWN | Details |
master_reset_end | 406B | Master reset OK | msrc_UNKNOWN | Details | |
temp_unit_action | 4037 | temp unit action | msrc_UNKNOWN | Details | |
store_old_press_unit | 400F | Str. old unit | msrc_UNKNOWN | Details | |
calc_new_pressure_range_values | 4010 | Pres. units | msrc_UNKNOWN | Details | |
store_old_stat_press_unit | 403B | Str. old unit | msrc_UNKNOWN | Details | |
calc_new_stat_pressure_range_values | 403C | Stat pres unit | msrc_UNKNOWN | Details | |
reset_factory_data | 401C | Factory reset | ATTENTION! This will reset all user configured data to factory default values! | msrc_UNKNOWN | Details |
loop_test | 1002 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
burn_eeprom | 100C | Grabar EEPROM | Burn Electrically Erasable Read Only Memory- Operation where the Field Device will copy what is in its Random Access Memory into the Electrically Erasable Read Only Memory, thus making changes by the Host permanent | msrc_UNKNOWN | Details |
zero_trim | 1006 | Zero trim | Zero trim- Make the sensor input the new zero input reference | msrc_UNKNOWN | Details |
applied_rerange | 1007 | Apply values | Applied values- Perform a device rerange by applying the desired Upper Range Value and Lower Range Values to the device input | msrc_UNKNOWN | Details |
send_warning | 1399 | Send Warning | Send Warning- Sends a unit code warning to the user. | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |