Reference ID | Label | String |
---|---|---|
0x00190001 | density_3680 | 3680 Dens |
0x00190002 | steam_quality_3280 | 3280 Steam qual |
0x001A0001 | ABB_DPK_pressure | DPK Pres |
0x001A0002 | ABB_PX_pressure | PX Pres |
0x001A0003 | ABB_DPK_temperature | DPK Temp |
0x001A0004 | valve_positioner | Valve Position |
0x001A0005 | flow_device | Flow |
0x001A0006 | level_device | Level |
0x001F0001 | mass_flow_9712 | 9712 Mass flo |
0x001F0002 | mass_flow_9739 | 9739 Mass flo |
0x001F0003 | mass_flow_9701 | 9701 |
0x001F0004 | mass_flow_9720 | 9720 |
0x00260001 | pressure_3051 | 3051 |
0x00260002 | pressure_1151s | 1151 |
0x00260003 | pressure_3001c | 3001C HTG |
0x00260004 | pressure_3001l | 3001L HTG |
0x00260005 | pressure_3051c | 3051C |
0x00260006 | temperature_3044 | 3044 Temp |
0x00260007 | mag_flow_8712 | Magmeter |
0x00260008 | mag_flow_8712H | Mag HS |
0x00260009 | htg_3201 | 3201 SAM |
0x0026000A | htg_3202 | 3202 SAM |
0x0026000B | temperature_3044C | 3044C Temp |
0x0026000C | pressure_1152s | 1152 |
0x0026000D | vortex_flow_8800 | Vortex |
0x0026000E | pressure_3051clp | 3051C LP |
0x0026000F | pressure_3001s | 3001S HTG |
0x00260010 | pressure_2001 | 2001 |
0x00260011 | level_4050 | 4050 |
0x00260012 | ascii_term | ASCII Term |
0x00260014 | mv_3095 | 3095MV |
0x00260015 | temperature_544 | 544 Temp |
0x00260016 | temperature_644 | 644 Temp |
0x00260017 | temperature_3144 | 3144 Temp |
0x00260018 | temperature_3244 | 3244 Temp |
0x00260019 | multi_3095FT | 3095FT |
0x0026001A | level_3700 | 3700 |
0x0026001B | level_3750 | 3750 |
0x0026001C | TRI_LOOP | Tri-Loop |
0x0026001D | c_3095 | 3095C |
0x0026001E | mm_3095 | 3095MM |
0x0026001F | tank_3701 | 3701 |
0x00260020 | level_3300 | 3300 |
0x00260021 | asu_3702 | 3702ASU |
0x00260022 | pressure_2088s | 2088 Smart |
0x00260023 | probar | ProBar |
0x00260024 | massprobar | Mass ProBar |
0x00260025 | prov | ProV |
0x00260026 | pressure_2090s | 2090 Smart |
0x00260027 | probar_uc | ProBar UC |
0x00260028 | d_2055 | 2055D |
0x00260029 | pv_3095 | 3095PV |
0x0026002A | sentry | Sentry |
0x002E0001 | ph_1181 | 2081 pH |
0x002E0002 | ph_1054 | 2054 pH |
0x002E0003 | conductivity_1181 | 2081 Cond |
0x002E0004 | conductivity_1054 | 2054 Cond |
0x002E0005 | ph_3081 | 3081pH |
0x002E0006 | c_3081 | 3081C |
0x002E0007 | ph_orp_54 | 54pH/ORP |
0x002E0008 | c_54 | 54eC |
0x00FA0001 | InH2O | inH2O |
0x00FA0002 | InHg | inHg |
0x00FA0003 | FtH2O | ftH2O |
0x00FA0004 | mmH2O | mmH2O |
0x00FA0005 | mmHg | mmHg |
0x00FA0006 | psi | psi |
0x00FA0007 | bar | bar |
0x00FA0008 | mbar | mbar |
0x00FA0009 | g_SqCm | g/Sqcm |
0x00FA000A | kg_SqCm | kg/Sqcm |
0x00FA000B | PA | Pa |
0x00FA000C | kPA | kPa |
0x00FA000D | torr | torr |
0x00FA000E | ATM | atm |
0x00FA000F | CuFt_min | Cuft/min |
0x00FA0010 | gal_min | gal/min |
0x00FA0011 | l_min | L/min |
0x00FA0012 | ImpGal_min | Impgal/min |
0x00FA0013 | CuMtr_hr | Cum/h |
0x00FA0014 | ft_s | ft/s |
0x00FA0015 | mtr_s | m/s |
0x00FA0016 | gal_s | gal/s |
0x00FA0018 | l_s | L/s |
0x00FA0019 | MilL_day | ML/d |
0x00FA001A | CuFt_s | Cuft/s |
0x00FA001B | CuFt_day | Cuft/d |
0x00FA001C | CuMtr_s | Cum/s |
0x00FA001D | CuMtr_day | Cum/d |
0x00FA001E | ImpGal_hr | Impgal/h |
0x00FA001F | ImpGal_day | Impgal/d |
0x00FA0020 | degC | degC |
0x00FA0021 | degF | degF |
0x00FA0022 | degR | degR |
0x00FA0023 | Kelvin | Kelvin |
0x00FA0024 | mV | mV |
0x00FA0025 | Ohm | ohm |
0x00FA0026 | Hz | Hz |
0x00FA0027 | mA | mA |
0x00FA0028 | gal | gal |
0x00FA0029 | liter | L |
0x00FA002A | ImpGal | Impgal |
0x00FA002B | CuMtr | Cum |
0x00FA002C | ft | ft |
0x00FA002D | meter | m |
0x00FA002E | bbl | bbl |
0x00FA002F | in | in |
0x00FA0030 | cm | cm |
0x00FA0031 | mm | mm |
0x00FA0032 | min | min |
0x00FA0033 | sec | s |
0x00FA0034 | hr | h |
0x00FA0035 | day | d |
0x00FA0036 | cpoise | cP |
0x00FA0037 | uMho | uMho |
0x00FA0038 | Percent | % |
0x00FA0039 | v | V |
0x00FA003A | pH | pH |
0x00FA003B | gram | g |
0x00FA003C | kg | kg |
0x00FA003D | MetTon | MetTon |
0x00FA003E | lb | lb |
0x00FA003F | ShTon | STon |
0x00FA0040 | LTon | LTon |
0x00FA0041 | g_s | g/s |
0x00FA0042 | g_min | g/min |
0x00FA0043 | g_hr | g/h |
0x00FA0044 | kg_s | kg/s |
0x00FA0045 | kg_min | kg/min |
0x00FA0046 | kg_hr | kg/h |
0x00FA0047 | kg_day | kg/d |
0x00FA0048 | MetTon_min | MetTon/min |
0x00FA0049 | MetTon_hr | MetTon/h |
0x00FA004A | MetTon_day | MetTon/d |
0x00FA004B | lb_s | lb/s |
0x00FA004C | lb_min | lb/min |
0x00FA004D | lb_hr | lb/h |
0x00FA004E | lb_day | lb/d |
0x00FA004F | ShTon_min | STon/min |
0x00FA0050 | ShTon_hr | STon/h |
0x00FA0051 | ShTon_day | STon/d |
0x00FA0052 | LTon_hr | LTon/h |
0x00FA0053 | LTon_day | LTon/d |
0x00FA0054 | SGU | SGU |
0x00FA0055 | g_CuCm | g/Cucm |
0x00FA0056 | kg_CuMtr | kg/Cum |
0x00FA0057 | lb_gal | lb/gal |
0x00FA0058 | lb_CuFt | lb/Cuft |
0x00FA0059 | g_ml | g/mL |
0x00FA005A | kg_l | kg/L |
0x00FA005B | g_l | g/L |
0x00FA005C | lb_CuIn | lb/Cuin |
0x00FA005D | ShTon_CuYd | STon/Cuyd |
0x00FA005E | degTwad | degTwad |
0x00FA005F | degBrix | degBrix |
0x00FA0060 | degBaum_hv | degBaum hv |
0x00FA0061 | degBaum_lt | degBaum lt |
0x00FA0062 | degAPI | degAPI |
0x00FA0063 | Percent_sol_wt | % sol-wt |
0x00FA0064 | Percent_sol_vol | % sol-vol |
0x00FA0065 | degBall | degBall |
0x00FA0066 | proof_vol | proof/vol |
0x00FA0067 | proof_mass | proof/mass |
0x00FA0068 | bush | bush |
0x00FA0069 | CuYd | Cuyd |
0x00FA006A | CuFt | Cuft |
0x00FA006B | CuIn | Cuin |
0x00FA006C | mtr_hr | m/h |
0x00FA006D | CuFt_hr | Cuft/h |
0x00FA006E | CuMtr_min | Cum/min |
0x00FA006F | bbl_s | bbl/s |
0x00FA0070 | bbl_min | bbl/min |
0x00FA0071 | bbl_hr | bbl/h |
0x00FA0072 | bbl_day | bbl/d |
0x00FA0073 | gal_hr | gal/h |
0x00FA0074 | ImpGal_s | Impgal/s |
0x00FA0075 | l_hr | L/h |
0x00FA0076 | percent_StmQual | % Stm Qual |
0x00FA0077 | Ftin16 | ft.in16 |
0x00FA0078 | CuFt_lb | Cuft/lb |
0x00FA0079 | Percent_plato | % plato |
0x00FA007A | centi_stokes | cSt |
0x00FA007B | pico_farads | pF |
0x00FA007C | mega_pascals | MPa |
0x00FA007D | in_H2O_4_degrees_C | inH2O @4DegC |
0x00FA007E | mm_H2O_4_degrees_C | mmH2O @4DegC |
0x00FA007F | hecto_liter | hL |
0x00FA0080 | gallons_per_day | gal/d |
0x00FA0081 | bbl_liq | bbl(liq) |
0x00FA0082 | ounce | ounce |
0x00FA0083 | foot_pound_force | ft lbf |
0x00FA0084 | kilo_watt | kW |
0x00FA0085 | kilo_watt_hour | kWh |
0x00FA0086 | horsepower | hp |
0x00FA0087 | mega_calorie | Mcal |
0x00FA0088 | mega_joule | MJ |
0x00FA0089 | british_thermal_unit | Btu |
0x00FA008A | normal_cubic_meter | NmlCum |
0x00FA008B | normal_liter | NmlL |
0x00FA008C | standard_cubic_feet | StdCuft |
0x00FA008D | mega_calorie_per_hour | Mcal/h |
0x00FA008E | mega_joule_per_hour | MJ/h |
0x00FA008F | british_thermal_unit_per_hour | Btu/h |
0x00FA0090 | normal_cubic_meter_per_hour | NmlCum/h |
0x00FA0091 | normal_liter_per_hour | NmlL/h |
0x00FA0092 | standard_cubic_feet_per_minute | StdCuft/min |
0x00FA0093 | deka_therm | datherm |
0x00FA0094 | parts_per_million | ppm |
0x00FA0095 | MillionGal_day | MMgal/d |
0x00FA0096 | uSiemen_cm | uS/cm |
0x00FA0097 | mSiemen_cm | mS/cm |
0x00FA0098 | kOhm | kO |
0x00FA0099 | newton | N |
0x00FA009A | newton_meter | Nm |
0x00FA009B | in_s | in/s |
0x00FA009C | in_min | in/min |
0x00FA009D | ft_min | ft/min |
0x00FA009E | deg_s | deg/s |
0x00FA009F | rpm | rpm |
0x00FA00A0 | degrees | deg |
0x00FA00A1 | rev_s | rev/s |
0x00FA00A2 | radian | rad |
0x00FA00A3 | in_H2O_60_degrees_F | inH2O @60DegF |
0x00FA00A4 | ug_l | ug/L |
0x00FA00A5 | ug_m3 | ug/Cum |
0x00FA00A6 | percent_consistency | %Cs |
0x00FA00A7 | volume_percent | Vol% |
0x00FA00A8 | ml_l | mL/L |
0x00FA00A9 | ul_l | uL/L |
0x00FA00AA | percent_lel | %LEL |
0x00FA00AB | ppb | ppb |
0x00FB0001 | linear | Linear |
0x00FB0002 | square_root | Sq root |
0x00FB0007 | special_curve | Spcl curve |
0x00FB0008 | square_root_plus_special_curve | Sq root+ spcl curve |
0x00FB0009 | square_root_to_the_third_power_plus_special_curve | Sq R to 3rd P+SCurv |
0x00FB000A | square_root_to_the_fifth_power_plus_special_curve | Sq R to 5th P+SC |
0x00FB000B | square_root_to_the_third_power_sup | Sq root to 3rd powr |
0x00FB000C | square_root_to_the_fifth_power_sup | Sq root to 5th powr |
0x00FB000D | square | Square |
0x00FB000E | discrete_switch | discrete (switch) |
0x00FC0001 | carbon_steel | Carbon Steel |
0x00FC0002 | stainless_steel_304 | 304 SST |
0x00FC0003 | stainless_steel_316 | 316 SST |
0x00FC0004 | hastelloy_c | Hast-C |
0x00FC0005 | monel | Monel |
0x00FC0006 | tantalum | Tantalum |
0x00FC0007 | titanium | Titanium |
0x00FC0008 | pt_ir | Pt-Ir |
0x00FC0009 | alloy_20 | Alloy 20 |
0x00FC000A | co_cr_ni | Co-Cr-Ni |
0x00FC000B | ptfe | PTFE |
0x00FC000C | vito | Viton |
0x00FC000D | buna_n | Buna-N |
0x00FC000E | ethyl_prop | Ethyl-Prop |
0x00FC000F | urethane | Urethane |
0x00FC0011 | tefzel | Tefzel |
0x00FC0012 | ryton | Ryton |
0x00FC0013 | ceramic | Ceramic |
0x00FC0015 | pvc | PVC |
0x00FC0016 | nitrile_rubber | Nitrile Rubber |
0x00FC0017 | kalrez | Kalrez |
0x00FC0018 | inconel | Inconel |
0x00FC0019 | kynar | Kynar |
0x00FC001A | aluminium | Al |
0x00FC001B | nickel | Nickel |
0x00FC001C | hastelloy_c276 | Hast-C276 |
0x00FC001D | monel_400 | Monel-400 |
0x00FC001E | fep | FEP |
0x00FC001F | stainless_steel_316_ti | 316 SST Ti |
0x00FC0020 | gold_monel | Gold monel |
0x00FC0021 | stainless_steel_316l_sup | 316L SST |
0x00FC0022 | klinger_c4401 | 4401 |
0x00FC0023 | thermotork | Thermotork |
0x00FC0024 | grafoil | Grafoil |
0x00FC0025 | ptfe_coated_316l_sst | PTFE coated 316L SST |
0x00FC0026 | gold_plated_hastelloy_c276 | Gold plated Hast C276 |
0x00FC0027 | ptfe_graphite | PTFE Graphite |
0x00FC0028 | ptfe_glass | PTFE Glass |
0x00FC0029 | PTFE_hastelloy | PTFE/Hastelloy |
0x00FC002A | stainless_steel_CF_8M | SST CF-8M |
0x00FC002B | hastelloy_sst | Hastelloy C/SST |
0x00FC002C | gold_plated_sst | gold plated SST |
0x00FC002D | aflas | Aflas |
0x00FD0001 | Acromag | Acromag |
0x00FD0002 | Allen_Bradley | Allen Bradley |
0x00FD0003 | Ametek | Ametek |
0x00FD0004 | Analog_Devices | Analog Devices |
0x00FD0006 | Beckman | Beckman |
0x00FD0007 | Bell_Microsensor | Bell Microsensor |
0x00FD0008 | Bourns | Bourns |
0x00FD0009 | Bristol_Babcock | Bristol Babcock |
0x00FD000A | Brooks_Instrument | Brooks Instrument |
0x00FD000B | Chessell | Chessell |
0x00FD000C | Combustion_Engineering | Combustion Engineering |
0x00FD000D | Daniel_Industries | Daniel Industries |
0x00FD000E | Delta | Delta |
0x00FD000F | Dieterich_Standard | Dieterich Standard |
0x00FD0010 | Dohrmann | Dohrmann |
0x00FD0011 | Endress_and_Hauser | Endress & Hauser |
0x00FD0013 | Fisher_Controls | Fisher Controls |
0x00FD0014 | Foxboro | Foxboro |
0x00FD0015 | Fuji | Fuji |
0x00FD0017 | Honeywell | Honeywell |
0x00FD0018 | ITT_Barton | ITT Barton |
0x00FD0019 | KayRay_Sensall | Kay Ray/Sensall |
0x00FD001A | Kent | Kent |
0x00FD001B | Leeds_and_Northrup | Leeds & Northrup |
0x00FD001C | Leslie | Leslie |
0x00FD001D | M_System_Co | M-System Co. |
0x00FD001E | Measurex | Measurex |
0x00FD001F | Micro_Motion | Micro Motion |
0x00FD0020 | Moore_Industries | Moore Industries |
0x00FD0021 | Moore_Products | Moore Products |
0x00FD0022 | Ohkura_Electric | Ohkura Electric |
0x00FD0023 | Paine | Paine |
0x00FD0024 | Rochester_Instrument_Systems | Rochester Instrument Systems |
0x00FD0025 | Ronan | Ronan |
0x00FD0026 | Rosemount | Rosemount |
0x00FD0028 | Schlumberger | Schlumberger |
0x00FD0029 | Sensall | Sensall |
0x00FD002A | Siemens | Siemens |
0x00FD002C | Toshiba | Toshiba |
0x00FD002D | Transmation | Transmation |
0x00FD002E | Rosemount_Analytical | Rosemount Analytic |
0x00FD002F | Valmet | Valmet |
0x00FD0031 | Varec | Varec |
0x00FD0032 | Viatran | Viatran |
0x00FD0033 | Weed | Weed |
0x00FD0034 | Westinghouse | Westinghouse |
0x00FD0035 | Xomox | Xomox |
0x00FD0036 | Yamatake | Yamatake |
0x00FD0037 | Yokogawa | Yokogawa |
0x00FD0038 | Nuovo_Pignone | Nuovo Pignone |
0x00FD0039 | Promac | Promac |
0x00FD003A | Exac_Corporation | Exac Corporation |
0x00FD003B | KDG_Mobrey | KDG Mobrey |
0x00FD003C | Acrom_Control_System | Arcom Control Systems |
0x00FD003D | Oval | Oval |
0x00FD003E | Princo | Princo |
0x00FD003F | Smar | Smar |
0x00FD0041 | Measurement_Technology | Measurement Technology |
0x00FD0042 | Applied_System_Technologies | Applied System Technologies |
0x00FD0043 | Samson | Samson |
0x00FD0044 | Sparling_Instruments | Sparling Instruments |
0x00FD0045 | Fireye | Fireye |
0x00FD0046 | Krohne | Krohne |
0x00FD0047 | Betz_Equipment | Betz |
0x00FD0048 | Druck | Druck |
0x00FD0049 | SOR | SOR |
0x00FD004A | Elcon_Instruments | Elcon Instruments |
0x00FD004B | EMCO | EMCO |
0x00FD004C | Termiflex | Termiflex Corporation |
0x00FD004D | VAF_Instruments | VAF Instruments |
0x00FD004E | Westlock_Controls | Westlock Controls |
0x00FD004F | Drexelbrook | Drexelbrook |
0x00FD0050 | K_TEK | K-TEK |
0x00FD0051 | Flowdata | Flowdata |
0x00FD0052 | Draeger | Draeger |
0x00FD0053 | Raytek | Raytek |
0x00FD0054 | Meridian_Instruments | Meridian Instruments |
0x00FD0055 | BTG | BTG |
0x00FD0056 | Magnetrol | Magnetrol |
0x00FD0058 | Milltronics | Milltronics |
0x00FD0059 | HELIOS | HELIOS |
0x00FD005A | Anderson_Instrument_Company | Anderson Instrument Company |
0x00FD005B | INOR | INOR |
0x00FD005C | ROBERTSHAW | ROBERTSHAW |
0x00FD005D | PEPPERL_FUCHS | PEPPERL+FUCHS |
0x00FD005E | ACCUTECH | ACCUTECH |
0x00FD005F | Flow_Measurement | Flow Measurement, Inc. |
0x00FD0060 | KAMSTRUP | KAMSTRUP |
0x00FD0061 | Knick | Knick |
0x00FD0062 | VEGA | VEGA |
0x00FD0063 | MTS_SYS_CORPS_SENSORS | MTS Systems Corp. |
0x00FD0064 | Masoneilan_DRESSER | Masoneilan-Dresser |
0x00FD0065 | Besta | BESTA |
0x00FD0066 | Peek_Measurement | Peek Measurement |
0x00FD0067 | Ohmart | Ohmart |
0x00FD0068 | Harold_Beck_and_Sons | Harold Beck and Sons, Inc. |
0x00FD0069 | rittmeyer_instrumentation | rittmeyer instrumentation |
0x00FD006A | rossel_messtechnik | Rossel Messtechnik |
0x00FD006B | WIKA | WIKA |
0x00FD006C | Bopp_and_Reuther_Heinrichs | Bopp&Reuther Heinrichs |
0x00FD006D | pr_eletronics | PR Electronics |
0x00FD006E | jordan_controls | Jordan Controls |
0x00FD006F | valcom | Valcom s.r.l. |
0x00FD0070 | us_electric_motors | US ELECTRIC MOTORS |
0x00FD0071 | apparatebau_hundsbach | Apparatebau Hundsbach |
0x00FD0072 | saab_tank_control | Saab Tank Control |
0x00FD0073 | Elsag_Bailey | Elsag Bailey |
0x00FD0074 | Foxboro_Eckardt | FOXBORO ECKARDT |
0x00FD0075 | Neles_Controls | Neles Controls |
0x00FD0076 | ISE_Magtech | ISE-Magtech |
0x00FD0077 | Delta_Weed | Delta/Weed |
0x00FD0078 | Dynisco | Dynisco |
0x00FD0079 | Spriano | Spriano |
0x00FD007A | Direct_Mesaurement | Direct Measurement |
0x00FD007B | Klay | Klay Instruments |
0x00FD007C | Action | Action Instruments |
0x00FD007D | Mmg_Automatiky | MMG Automatiky DTR |
0x00FD007E | Buerkert | Buerkert Fluid Control Systems |
0x00FD007F | Hersey | Hersey Measurement |
0x00FD0080 | Pondus | PONDUS INSTRUMENTS |
0x00FD0081 | Zap | ZAP S.A. Ostrow Wielkopolski |
0x00FD0082 | GLI | GLI |
0x00FD0083 | FRPT | Fisher-Rosemount Performance Technologies |
0x00FD0084 | Paper_Machine_Components | Paper Machine Components |
0x00FD0085 | Labom | LABOM |
0x00FD0086 | Danfoss | Danfoss |
0x00FD0087 | Turbo | Turbo |
0x00FD0088 | Tokyo_Keiso | TOKYO KEISO |
0x00FD0089 | SMC | SMC |
0x00FD008A | Status_Instruments | Status Instruments |
0x00FD008B | Huakong | Huakong |
0x00FD008C | Duon_System | Duon System |
0x00FD008D | Vortek_Instruments_LLC | Vortek Instruments, LLC |
0x00FD008E | AG_Crosby | AG Crosby |
0x00FD008F | Action_Instruments | Action Instruments |
0x00FD0090 | Keystone_Controls | Keystone Controls |
0x00FD0091 | Thermo_Electric_Company | Thermo Electric Co. |
0x00FD0092 | Flowserve | Flowserve |
0x00FE0001 | invalid_selection | Invalid selection |
0x00FE0002 | passed_parameter_too_large | Value was too high |
0x00FE0003 | passed_parameter_too_small | Value was too low |
0x00FE0004 | too_few_data_bytes_recieved | Too few data bytes received |
0x00FE0005 | lower_range_value_too_high | Lower range value too high |
0x00FE0007 | invalid_flange_type | Invalid flange type |
0x00FE0008 | lower_range_value_too_low | Lower range value too low |
0x00FE000A | upper_range_value_too_high | Upper range value too high |
0x00FE000C | upper_range_value_too_low | Upper range value too low |
0x00FE0012 | URV_and_LRV_out_of_limits | Lower range value and upper range value out of limits |
0x00FE0016 | set_to_nearest_possible_value | Set to nearest possible value |
0x00FE0018 | span_too_small | Span too small |
0x00FE0019 | new_LRV_pushed_URV_over_USL | New lower range value pushed upper range value over upper sensor limit |
0x00FE001B | invalid_transmitter_variable | Invalid field device variable code |
0x00FE001C | invalid_units | Invalid unit |
0x00FE001D | invalid_analog_output_number_code | Invalid analog output number code |
0x00FE0020 | invalid_alarm_config_code | Invalid alarm relay configuration code |
0x00FE0023 | invalid_alarm_number_code | Invalid alarm number code |
0x00FE0026 | invalid_liner_material_code | Invalid liner material code |
0x00FE0027 | invalid_sensor_material_code | Invalid sensor material code |
0x00FE0028 | invalid_base_mass_time_units | Invalid base mass time unit |
0x00FE0029 | invalid_base_mass_flow_units | Invalid base flow unit |
0x00FE002E | invalid_base_volume_time_units | Invalid base volume time unit |
0x00FE002F | invalid_base_volume_flow_units | Invalid base volume flow unit |
0x00FE0030 | incorrect_format | Incorrect format |
0x00FE0039 | invalid_alarm_xmtr_var_code | Invalid alarm variable index into field device variables |
0x00FE004C | invalid_transfer_function_code | Invalid transfer function |
0x00FF0004 | update_in_progress | Update In progress |
0x00FF0006 | no_command_specific_errors | No specific error |
0x00FF0007 | xmtr_specific_command_error | Field device specific error |
0x00FF0008 | access_restricted | Access restricted |
0x00FF0009 | update_failure | Update fail |
0x01000001 | in_write_protect_mode | In write protect mode |
0x01000002 | not_in_proper_current_mode | Not in fixed current mode |
0x01000003 | not_in_proper_anlg_output_mode | Not in analog output mode |
0x01000007 | in_multidrop_mode | In multidrop mode |
0x01010001 | applied_process_too_high | Applied process too high |
0x01010002 | applied_process_too_low | Applied process too low |
0x01070012 | cal_in_progress | Calibration in progress |
0x01080001 | buffer_overflow | Buffer overflow |
0x01080002 | longitudinal_parity_error | Longitudinal parity error |
0x01080003 | framing_error | Framing error |
0x01080004 | overrun_error | Overrun error |
0x01080005 | vertical_parity_error | Vertical parity error |
0x01090001 | PV_out_of_limits | Process applied to the primary variable is outside the operating limits of the field device |
0x01090002 | Non_PV_out_of_limits | Process applied to the non-primary variable is outside the operating limits of the field device |
0x01090003 | PV_analog_output_saturated | Analog output 1 and its digital representation are outside the operating range limits, and not responding to input |
0x01090004 | PV_analog_output_fixed | Analog output 1 and its digital representation are in fixed mode, and not responsive to input changes |
0x01090005 | more_status_available | Field device has more status available |
0x01090006 | cold_start | A reset or self test of the field device has occurred, or power has been removed and reapplied |
0x01090007 | configuration_changed | A modification has been made to the configuration of the field device |
0x01090008 | device_malfunction | Field device has malfunctioned due to a hardware error or failure |
0x010D000B | ansi_150 | ANSI 150 |
0x010D000C | ansi_300 | ANSI 300 |
0x010D000D | ansi_600 | ANSI 600 |
0x010D0010 | pn_40 | PN40 |
0x010D0015 | pn_100 | PN100 |
0x010D0016 | ansi_900 | ANSI 900 |
0x010D0017 | jis_10k | JIS 10K |
0x010D0018 | jis_20k | JIS 20K |
0x010D0019 | Union | Union |
0x01120005 | normal | Normal |
0x01120008 | fault | Fault |
0x01150001 | off | Off |
0x01150002 | on | On |
0x0115000A | not_used | Not used |
0x0115000B | none | None |
0x0115000C | unknown | Unknown |
0x0115000D | special | Spcl |
0x0115000E | expansion | Expansion |
0x0115000F | success | Success |
0x01150010 | high | Hi |
0x01150011 | low | Lo |
0x01150016 | do_not_poll | Do not poll |
0x01150017 | poll_as_primary_master | Poll as primary host |
0x01150018 | poll_as_secondary_master | Poll as secondary host |
0x01150019 | forward | Forward |
0x0115001A | reverse | Reverse |
0x0115001B | bi_directional | Bi directional |
0x0115001C | start | Start |
0x0115001D | stop | Stop |
0x0115001E | reset | Reset |
0x01150043 | bell_202_current | Bell 202 current |
0x01150044 | bell_202_voltage | Bell 202 voltage |
0x01150045 | Multisens_Dev | Multisnsr dev |
0x01150046 | EEPROM_Ctrl | Command #39, EEPROM cntrl, required |
0x01150047 | primary_variable | PV |
0x01150048 | percent_range_and_current | % range/current |
0x01150049 | all_process_variables_and_current | Process vars/crnt |
0x0115004A | burn_eeprom | Burn EEPROM |
0x0115004B | restore_shadow_ram | Restore shadow RAM |
0x0115004C | no | No |
0x0115004D | yes | Yes |
0x0115004E | rs_485 | RS-485 |
0x0115004F | protocol_bridge_device | Protocol bridge dev |
0x01150050 | rs_232 | RS-232 |
0x01160001 | bus_devices | Online |
0x01160029 | hot_key | Hot key |
0x01170001 | selftest | Self test |
0x0117000B | loop_test | Loop test |
0x0117000C | DAC_trim | D/A trim |
0x0117000D | zero_trim | Zero trim |
0x0117000E | scaled_DAC_trim | Scaled D/A trim |
0x0117000F | leaving_fixed_current_mode | Leaving fixed crnt mode |
0x01170010 | perform_auto_zero | Perform auto zero |
0x01170014 | trim_analog_output | Trim analog output |
0x01170015 | fix_analog_output | Fix analog output |
0x0117001D | field_device_variable_zero_trim | Dev var zero trim |
0x0117001E | apply_values | Apply values |
0x01170020 | aborting_return_to_normal | Aborting return to normal |
0x01170021 | set_loop_to_manual | Set loop to manual |
0x01180001 | range_values | Range values |
0x01190005 | manufacturer_id | Manufacturer |
0x01190006 | device_type | Model |
0x01190007 | number_of_request_preambles | Num req preams |
0x01190008 | universal_revision | Universal rev |
0x01190009 | transmitter_revision | Fld dev rev |
0x0119000A | software_revision | Software rev |
0x0119000B | hardware_revision | Hardware rev |
0x0119000C | device_flags | Dev flags |
0x0119000D | device_identification | Dev id |
0x0119000E | polling_address | Poll addr |
0x0119000F | tag | Tag |
0x01190010 | message | Message |
0x01190011 | descriptor | Descriptor |
0x01190012 | date | Date |
0x01190013 | write_protect | Write protect |
0x01190014 | private_label_distributor | Distributor |
0x01190015 | final_assembly_number | Final asmbly num |
0x01190017 | EEPROM_select | EEPROM select |
0x01190018 | xmtr_specific_status_0 | Status group 1 |
0x01190019 | xmtr_specific_status_1 | Status group 2 |
0x0119001A | xmtr_specific_status_2 | Status group 3 |
0x0119001B | xmtr_specific_status_3 | Status group 4 |
0x0119001C | xmtr_specific_status_4 | Status group 5 |
0x0119001D | xmtr_specific_status_5 | Status group 6 |
0x0119001E | operating_mode_1 | Operate mode 1 |
0x0119001F | operating_mode_2 | Operate mode 2 |
0x01190020 | analog_output_saturated | AO saturated |
0x01190021 | analog_output_fixed | AO fixed |
0x0119002A | xmtr_specific_status_14 | Status group 15 |
0x0119002B | xmtr_specific_status_15 | Status group 16 |
0x0119002C | xmtr_specific_status_16 | Status group 17 |
0x0119002D | unit_tag | Dev tag |
0x0119002E | unit_descriptor | Dev des |
0x0119002F | unit_date | Dev date |
0x01190030 | number_of_response_preambles | Num resp preams |
0x01190031 | burst_command_number | Burst option |
0x01190032 | burst_mode_select | Burst mode |
0x01190035 | alarm_select | AO Alrm typ |
0x01190037 | transfer_function | Xfer fnctn |
0x01190066 | totalizer_control | Totlizer cntrl |
0x01190073 | damping_value | Damp |
0x01190078 | sv | SV |
0x0119007A | tv | TV |
0x0119007C | range_units | Rnge unit |
0x01190091 | units | Unit |
0x01190092 | time | Time |
0x011900AA | mass_total_units | Mass totl unit |
0x011900AE | temperature_units | Temp unit |
0x011900B4 | temperature_urv | Temp URV |
0x011900B5 | temperature_lrv | Temp LRV |
0x011900BC | density_units | Dens unit |
0x011900C1 | density_urv | Dens URV |
0x011900C2 | density_lrv | Dens LRV |
0x011900C3 | density_url | Dens URL |
0x011900C4 | density_lrl | Dens LRL |
0x011900C6 | density_minimum_span | Dens min span |
0x011900CF | volume_flow_urv | Vol flo URV |
0x011900D0 | volume_flow_lrv | Vol flo LRV |
0x011900D5 | volume_total_units | Vol flo totl unit |
0x011900DE | analog_upper_limit | Anlog upr limit |
0x011900DF | analog_lower_limit | Anlog lor limit |
0x011900E0 | analog_units | Anlog unit |
0x011900E1 | add_analog_damping | Added damp |
0x011900E2 | analog_output_1_cutoff | AO1 Cutoff |
0x011900EC | analog_output_2_cutoff | AO2 Cutoff |
0x01190103 | fixed_frequency | Fixed freq |
0x01190114 | cutoff_type | Cutoff typ |
0x01190119 | alarm_number | Alrm num |
0x01190170 | physical_signalling_code | Physicl signl code |
0x01190171 | fourth_variable_is | 4V is |
0x01190172 | tertiary_variable_is | TV is |
0x01190173 | secondary_variable_is | SV is |
0x01190174 | primary_variable_is | PV is |
0x01190175 | xmtr_specific_status_17 | Status group 18 |
0x01190176 | xmtr_specific_status_18 | Status group 19 |
0x01190177 | xmtr_specific_status_19 | Status group 20 |
0x01190178 | xmtr_specific_status_20 | Status group 21 |
0x01190179 | xmtr_specific_status_21 | Status group 22 |
0x0119017A | xmtr_specific_status_22 | Status group 23 |
0x0119017B | xmtr_specific_status_23 | Status group 24 |
0x0119017C | xmtr_specific_status_24 | Status group 25 |
0x011A000B | temperature | Temp |
0x011A000D | density | Dens |
0x011A0016 | analog_1_cutoff | AO1 Cutoff |
0x011A0019 | urv | URV |
0x011A001A | lrv | LRV |
0x011A001B | usl | USL |
0x011A001C | lsl | LSL |
0x011A001D | minimum_span | Min span |
0x011A0020 | analog_output_value | AO |
0x011A0021 | analog_output_units | AO unit |
0x011A0022 | analog_output_lower_endpoint | AO lo end pt |
0x011A0023 | analog_output_upper_endpoint | AO hi end pt |
0x01240005 | seconds_added_damping_value_help | Analog Output Added Damping Value- Damping time constant applied the Analog Output. The units of this variable are always in seconds. |
0x01240006 | analog_output_upper_end_point_help | Analog Output Upper Endpoint Value- Defines the upper endpoint, of the respective Analog Output, for normal operating conditions |
0x01240007 | analog_output_lower_end_point_help | Analog Output Lower Endpoint Value- Defines the lower endpoint, of the respective Analog Output, for normal operating conditions |
0x01240008 | digital_units_help | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit |
0x0124000A | percent_of_range_help | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. |
0x0124000C | upper_sensor_limit_help | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value |
0x0124000D | lower_sensor_limit_help | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value |
0x0124000E | minimum_span_help | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value |
0x01240011 | upper_range_value_help | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. |
0x01240012 | lower_range_value_help | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. |
0x01240013 | seconds_damping_value_help | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. |
0x01240015 | transmitter_variable_help | Field Device Variable- Digital measurement that changes with respect to time without user intervention |
0x0124001B | final_assembly_number_help | Final Assembly Number- Number that is used for identification purposes, and is associated with the overall Field Device |
0x0124001C | private_label_distributor_help | Private Label Distributor- References the company that is responsible for the distribution of this Field Device to customers |
0x0124001D | write_protect_mode_help | Write Protect Mode- Indicates whether variables can be written to the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. Depending on the Field Device, this is a mode that is controllable by the user, either via the Field Device hardware or the HART Protocol. |
0x0124001E | date_help | Date- Gregorian calendar date that is stored in the Field Device. This date can be used by the user in any way. There is no specific recommended use. |
0x0124001F | discriptor_help | Descriptor- Text that is associated with the Field Device. This text can be used by the user in any way. There is no specific recommended use. |
0x01240020 | message_help | Message- Text that is associated with the Field Device. This text can be used by the user in any way. There is no recommended use. |
0x01240021 | polling_address_help | Polling Address- Address used by the Host to identify a Field Device, and changeable by the User to control: the Multidrop Mode for Analog Output 1), and the Analog Output Fixed Mode of Analog Output 1) |
0x01240022 | field_device_identification_help | Field Device Identification- Uniquely identifies the Field Device when combined with the Manufacturer Identification and Device Type. Therefore, this variable cannot be modified by the Host user. |
0x01240023 | field_device_flags_help | Field Device Flags- Describes special features of the Field Device that affect the Data Link Layer |
0x01240024 | physical_signalling_code_help | Physical Signaling Code- The Physical Signaling Code describes the type of Physical Layer that has been implemented in the hardware that is responsible for the HART Communication port |
0x01240025 | hardware_revision_help | Hardware Revision- Revision that corresponds to the electronics hardware of the Field Device |
0x01240026 | field_device_software_revision_help | Field Device Software Revision- This revision corresponds to the software or firmware, that is embedded in the Field Device |
0x01240027 | field_device_revision_help | Field Device Revision- Revision of the Field Device Specific Device Description, that the Field Device conforms to |
0x01240028 | universal_revision_help | Universal Revision- Revision of the Universal Device Description, that the Field Device conforms to |
0x01240029 | number_of_request_preambles_help | Number of Request Preambles- Number of Preambles required from the Host request by the Field Device |
0x0124002A | manufacturers_device_type_help | Model- References the type of Field Device, usually an advertised model number, that is unique to a single manufacturer |
0x0124002B | manufacturer_id_code_help | Manufacturer Identification Code- References a specific manufacturer, which is usually a company name, that is responsible for the manufacture of this Field Device |
0x0124002C | field_device_status_help | Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process |
0x0124002D | communications_error_summary_help | Communications Error Summary- The Field Device has detected the following error condition while attempting to receive the Host request. Therefore the Command was not accepted, and the Host request caused no change to occur in the Field Device. |
0x0124002E | command_specific_response_code_help | Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself. |
0x0124002F | burst_mode_select_help | Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. |
0x01240030 | burst_command_number_help | Burst Option- Selects the variable(s) that will be Bursted if Burst Mode is enabled |
0x01240031 | index_into_dynamic_variables_array_help | Index into Dynamic Variables Array- An index that identifies a Field Device Variable that is dynamic with respect to time, with no user input |
0x01240032 | index_into_dynamic_variables_array_1_help | Index into Dynamic Variables Array- Is the first an array of addresses, whose value is identified by the Field Device Variable Code |
0x01240033 | index_into_dynamic_variables_array_2_help | Index into Dynamic Variables Array- Is the second of an array of addresses, whose value identified by the Field Device Variable Code |
0x01240034 | index_into_dynamic_variables_array_3_help | Index into Dynamic Variables Array- Is the third of an array of addresses, whose value identified by the Field Device Variable Code |
0x01240035 | index_into_dynamic_variables_array_4_help | Index into Dynamic Variables Array- Is the fourth of an array of addresses, whose value identified by the Field Device Variable Code |
0x01240036 | fourth_variable_code_is_help | Fourth Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Fourth Variable dynamic variable |
0x01240037 | tertiary_variable_code_is_help | Tertiary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Tertiary Variable dynamic variable |
0x01240038 | secondary_variable_code_is_help | Secondary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Secondary Variable dynamic variable |
0x01240039 | primary_variable_code_is_help | Primary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Primary Variable dynamic variable |
0x0124003A | analog_output_fixed_help | Field Device Specific Dynamic Variable Analog Output Fixed- Data that indicates which of the Analog Outputs are, or are not, Fixed. The analog and digital Analog Outputs for the Dynamic Variable are held at a constant value (depending on the Mode of the Field Device). They will not respond to the applied process. |
0x0124003B | analog_output_saturated_help | Field Device Specific Dynamic Variable Analog Output Saturated- Data that indicates which of the Analog Outputs are, or are not, saturated. The analog and digital Analog Outputs for the Dynamic Variable are beyond their limits and no longer represent the true applied process. |
0x0124003C | operating_mode_2_help | Field Device Specific Operating Mode 2- A possible mode of operation in Field Device |
0x0124003D | operating_mode_1_help | Field Device Specific Operating Mode 1- A possible mode of operation in Field Device |
0x0124003E | index_four_into_analog_output_array_help | Index into Analog Output Array- Is the fourth of an array of addresses, whose value is identified by the Analog Output Code |
0x0124003F | index_three_into_analog_output_array_help | Index into Analog Output Array- Is the third of an array of addresses, whose value is identified by the Analog Output Code |
0x01240040 | index_two_into_analog_output_array_help | Index into Analog Output Array- Is the second of an array of addresses, whose value is identified by the Analog Output Code |
0x01240041 | index_one_into_analog_output_array_help | Index into Analog Output Array- Is the first of an array of addresses, whose value is identified by the Analog Output Code |
0x01240042 | analog_output_number_help | Analog Output Number- Index into an array of Analog Outputs |
0x01240043 | number_of_response_preambles_help | Number of Response Preambles- Number of Preambles to be sent in the response message from the Field Device to the Host |
0x01240044 | unit_date_help | Field Device Date- Georgian calendar date associated with the Field Device, when there are other Date(s) in the Field Device that relate to sub applications |
0x01240045 | unit_descriptor_help | Field Device Descriptor- Text that is stored in the Field Device, when there are other Descriptors in the Field Device that relate to sub applications |
0x01240046 | unit_tag_help | Field Device Tag- Text that is stored in the Field Device, when there are other Tags in the Field Device that relate to sub applications |
0x01240047 | field_device_status_16_help | Field Device Specific Status Byte 17- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240048 | field_device_status_15_help | Field Device Specific Status Byte 16- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240049 | field_device_status_14_help | Field Device Specific Status Byte 15- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240052 | field_device_status_5_help | Field Device Specific Status Byte 6- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240053 | field_device_status_4_help | Field Device Specific Status Byte 5- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240054 | field_device_status_3_help | Field Device Specific Status Byte 4- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240055 | field_device_status_2_help | Field Device Specific Status Byte 3- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240056 | field_device_status_1_help | Field Device Specific Status Byte 2- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240057 | field_device_status_0_help | Field Device Specific Status Byte 1- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240058 | eeprom_select_help | Electrically Erasable Read Only Memory Selection- Controls the data in: EEPROM Read Only Memory / Read Only Memory |
0x01240059 | burn_eeprom_help | Burn Electrically Erasable Read Only Memory- Operation where the Field Device will copy what is in its Random Access Memory into the Electrically Erasable Read Only Memory, thus making changes by the Host permanent |
0x0124005A | leaving_fixed_current_mode_help_1 | Leaving Fixed Current Mode- Takes the selected Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output then tracks the input |
0x0124005B | leaving_fixed_current_mode_help_2 | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output the tracks the input |
0x0124005C | zero_trim_help | Zero trim- Make the sensor input the new zero input reference |
0x0124005D | digital_to_analog_trim_help | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output |
0x0124005E | digital_to_analog_scaled_trim_help | Digital to Analog Scaled Trim- Allows the calibration of the Analog Output with an external reference at the operating endpoints of the Analog Output |
0x0124005F | fix_analog_output_help | Fix Analog Output- Allows the User to manually manipulate a selected Analog Output to a selected constant output value |
0x01240060 | applied_values_help | Applied values- Perform a device rerange by applying the desired Upper Range Value and Lower Range Values to the device input |
0x01240061 | loop_test_help | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value |
0x01240062 | tag_help | Tag- Text that is associated with the Field Device installation. This text can be used by the user in any way. A recommended use is as a unique label to a plant that correlates to a Field Device label: a plant drawing, or on a Control System. This variable is also used as a type of data link layer address handle. |
0x01240063 | field_device_status_17_help | Field Device Specific Status Byte 18- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240064 | field_device_status_18_help | Field Device Specific Status Byte 19- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240065 | field_device_status_19_help | Field Device Specific Status Byte 20- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240066 | field_device_status_20_help | Field Device Specific Status Byte 21- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240067 | field_device_status_21_help | Field Device Specific Status Byte 22- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240068 | field_device_status_22_help | Field Device Specific Status Byte 23- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240069 | field_device_status_23_help | Field Device Specific Status Byte 24- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x0124006A | field_device_status_24_help | Field Device Specific Status Byte 25- Data that has Field Device status information relating to: failures / warnings / status of process's |
0x01240074 | multi_sensor_fld_dev | Multi Sensor Field Device |
0x01240075 | not_write_protected | Not Write Protected |
0x01240076 | write_protected | Write Protected |
0x01240077 | pv_help | Primary Variable |
0x01240078 | percent_rnge_help | Percent of Range of the Primary Variable and Analog Output 1 Current |
0x01240079 | all_process_var_help | All Dynamic Process Variables and Analog Output 1 Current |
0x01240094 | device_reset_help | Device Reset- Commands the electronics to perform a reset. This is equivalent to cycling the power off and then back on to the field device. |
0x01260003 | analog_output_1 | AO1 |
0x01260004 | analog_output_2 | AO2 |
0x01260005 | pressure | Pres |
0x01260009 | blank | |
0x01260013 | sensor_unit | Snsr unit |
0x0126001B | cutoff | Cutoff |
0x0126001C | setpoint | Set pt |
0x0126001D | setpoint_units | Set pt unit |
0x0126001E | variable_code | Var code |
0x0126001F | type_code | Typ code |
0x01260055 | analog_output_3 | AO3 |
0x01260056 | analog_output_4 | AO4 |
0x012C0027 | hold_last_output_value | Hold last out valu |
0x012D0001 | remove_loop_from_auto | WARN-Loop should be removed from automatic control |
0x012D0002 | loop_output | Output |
0x012D0003 | fld_dev_otpt_fixed | Fld dev output is fixed at %0 mA |
0x012D0004 | choose_analog_output_level | Choose analog output level |
0x012D0005 | choices_4_20_other_end | 4mA;20mA;Other;End |
0x012D0006 | abort_last_error | Aborting method due to last error |
0x012D0007 | setting_fld_dev_4_ma | Setting fld dev output to 4mA |
0x012D0008 | enter_meter_value | Enter meter value |
0x012D0009 | fld_dev_otpt_equal_ref_meter | Fld dev output %0 mA equal to reference meter? |
0x012D000A | yes_no | Yes;No |
0x012D000B | setting_fld_dev_20_ma | Setting fld dev output to 20mA |
0x012D000C | trim_scaled_from_low_to_high | Trim will be scaled from %{low} to %{high} |
0x012D000D | set_scale_lo_output_value | Set scale- Lo output value |
0x012D000E | set_scale_hi_output_value | Set scale- Hi output value |
0x012D000F | proceed_change | Proceed;Change |
0x012D0010 | high_low_0_invalid | high - low = 0 is invalid |
0x012D0011 | connect_reference_meter | Connect reference meter |
0x012D0012 | scaled_otpt_low_eq_dev | Scaled output: %{low} equal readout device? |
0x012D0013 | scaled_otpt_high_eq_dev | Scaled output: %{high} equal readout device? |
0x012D0014 | this_will_affect_snsr_cal | WARN-This will affect sensor calibration |
0x012D0015 | apply_0_input_to_snsr | Apply 0 input to sensor |
0x012D0016 | snsr_input_stabilizing | Sensor input stabilizing |
0x012D0017 | zero_the_input_and_try_again | Do you wish to zero the input and try again ? |
0x012D0018 | snsr_zero_succeeded | Sensor zero succeeded |
0x012D0019 | return_fld_dev_to_orig_otpt | Returning fld dev to original output |
0x012D001A | loop_may_be_returned_to_auto | NOTE-Loop may be returned to automatic control |
0x012D001B | apply_new_4ma_input | Apply new 4ma input |
0x012D001C | set_the | Set the: |
0x012D001D | choice_4_20_exit | 4mA;20mA;Exit |
0x012D001E | current_applied_process_val | Current applied process value: %{0} %{1} |
0x012D001F | set_4ma_read_new_leave | Set as 4mA value;Read new value;Leave as found |
0x012D0020 | apply_new_20ma_input | Apply new 20ma input |
0x012D0021 | set_20ma_read_new_leave | Set as 20mA value;Read new value;Leave as found |
0x012D0022 | remove_from_auto_befor_send | WARN-Remove loop from automatic control before sending. You may return loop to automatic control after sending. |
0x012D0023 | select_analog_output_to_trim | Select analog output to trim |
0x012D0024 | select_analog_output_units | Select analog output units |
0x012D0025 | select_fld_dev_var_snsr_trim | Select fld dev var sensor to trim |
0x012D0026 | enter_desired_analog_output | Enter desired analog output value |
0x012D0027 | new_value_end | New value;End |
0x012D0028 | fld_dev_AO_is_fixed_at | Feld dev %0 A0 is fixed at %1 %2 |
0x012D0029 | about_to_set_fld_dev_output | About to set fld dev output to %0 %1 |
0x012D002A | fld_dev_output_eq_ref_meter | Fld dev output %0 %1 equal to reference meter? |
0x012D002B | invalid_value_try_again | Invalid value try again |
0x012D002C | making_changes_permanent | Making changes permanent |
0x012D002D | previous_err_seen_brn_eeprom | The previous error was seen while trying to burn EEPROM |
0x012F0041 | fld_dev_stat1_1 | Fld dev stat1-1 |
0x012F0042 | fld_dev_stat1_2 | Fld dev stat1-2 |
0x012F0043 | fld_dev_stat1_3 | Fld dev stat1-3 |
0x012F0044 | fld_dev_stat1_4 | Fld dev stat1-4 |
0x012F0045 | fld_dev_stat1_5 | Fld dev stat1-5 |
0x012F0046 | fld_dev_stat1_6 | Fld dev stat1-6 |
0x012F0047 | fld_dev_stat1_7 | Fld dev stat1-7 |
0x012F0048 | fld_dev_stat1_8 | Fld dev stat1-8 |
0x012F0049 | fld_dev_stat2_1 | Fld dev stat2-1 |
0x012F004A | fld_dev_stat2_2 | Fld dev stat2-2 |
0x012F004B | fld_dev_stat2_3 | Fld dev stat2-3 |
0x012F004C | fld_dev_stat2_4 | Fld dev stat2-4 |
0x012F004D | fld_dev_stat2_5 | Fld dev stat2-5 |
0x012F004E | fld_dev_stat2_6 | Fld dev stat2-6 |
0x012F004F | fld_dev_stat2_7 | Fld dev stat2-7 |
0x012F0050 | fld_dev_stat2_8 | Fld dev stat2-8 |
0x012F0051 | fld_dev_stat3_1 | Fld dev stat3-1 |
0x012F0052 | fld_dev_stat3_2 | Fld dev stat3-2 |
0x012F0053 | fld_dev_stat3_3 | Fld dev stat3-3 |
0x012F0054 | fld_dev_stat3_4 | Fld dev stat3-4 |
0x012F0055 | fld_dev_stat3_5 | Fld dev stat3-5 |
0x012F0056 | fld_dev_stat3_6 | Fld dev stat3-6 |
0x012F0057 | fld_dev_stat3_7 | Fld dev stat3-7 |
0x012F0058 | fld_dev_stat3_8 | Fld dev stat3-8 |
0x012F0059 | fld_dev_stat4_1 | Fld dev stat4-1 |
0x012F005A | fld_dev_stat4_2 | Fld dev stat4-2 |
0x012F005B | fld_dev_stat4_3 | Fld dev stat4-3 |
0x012F005C | fld_dev_stat4_4 | Fld dev stat4-4 |
0x012F005D | fld_dev_stat4_5 | Fld dev stat4-5 |
0x012F005E | fld_dev_stat4_6 | Fld dev stat4-6 |
0x012F005F | fld_dev_stat4_7 | Fld dev stat4-7 |
0x012F0060 | fld_dev_stat4_8 | Fld dev stat4-8 |
0x012F0061 | fld_dev_stat5_1 | Fld dev stat5-1 |
0x012F0062 | fld_dev_stat5_2 | Fld dev stat5-2 |
0x012F0063 | fld_dev_stat5_3 | Fld dev stat5-3 |
0x012F0064 | fld_dev_stat5_4 | Fld dev stat5-4 |
0x012F0065 | fld_dev_stat5_5 | Fld dev stat5-5 |
0x012F0066 | fld_dev_stat5_6 | Fld dev stat5-6 |
0x012F0067 | fld_dev_stat5_7 | Fld dev stat5-7 |
0x012F0068 | fld_dev_stat5_8 | Fld dev stat5-8 |
0x012F0069 | fld_dev_stat6_1 | Fld dev stat6-1 |
0x012F006A | fld_dev_stat6_2 | Fld dev stat6-2 |
0x012F006B | fld_dev_stat6_3 | Fld dev stat6-3 |
0x012F006C | fld_dev_stat6_4 | Fld dev stat6-4 |
0x012F006D | fld_dev_stat6_5 | Fld dev stat6-5 |
0x012F006E | fld_dev_stat6_6 | Fld dev stat6-6 |
0x012F006F | fld_dev_stat6_7 | Fld dev stat6-7 |
0x012F0070 | fld_dev_stat6_8 | Fld dev stat6-8 |
0x012F0071 | fld_dev_stat15_1 | Fld dev stat15-1 |
0x012F0072 | fld_dev_stat15_2 | Fld dev stat15-2 |
0x012F0073 | fld_dev_stat15_3 | Fld dev stat15-3 |
0x012F0074 | fld_dev_stat15_4 | Fld dev stat15-4 |
0x012F0075 | fld_dev_stat15_5 | Fld dev stat15-5 |
0x012F0076 | fld_dev_stat15_6 | Fld dev stat15-6 |
0x012F0077 | fld_dev_stat15_7 | Fld dev stat15-7 |
0x012F0078 | fld_dev_stat15_8 | Fld dev stat15-8 |
0x012F0079 | fld_dev_stat16_1 | Fld dev stat16-1 |
0x012F007A | fld_dev_stat16_2 | Fld dev stat16-2 |
0x012F007B | fld_dev_stat16_3 | Fld dev stat16-3 |
0x012F007C | fld_dev_stat16_4 | Fld dev stat16-4 |
0x012F007D | fld_dev_stat16_5 | Fld dev stat16-5 |
0x012F007E | fld_dev_stat16_6 | Fld dev stat16-6 |
0x012F007F | fld_dev_stat16_7 | Fld dev stat16-7 |
0x012F0080 | fld_dev_stat16_8 | Fld dev stat16-8 |
0x012F0081 | fld_dev_stat17_1 | Fld dev stat17-1 |
0x012F0082 | fld_dev_stat17_2 | Fld dev stat17-2 |
0x012F0083 | fld_dev_stat17_3 | Fld dev stat17-3 |
0x012F0084 | fld_dev_stat17_4 | Fld dev stat17-4 |
0x012F0085 | fld_dev_stat17_5 | Fld dev stat17-5 |
0x012F0086 | fld_dev_stat17_6 | Fld dev stat17-6 |
0x012F0087 | fld_dev_stat17_7 | Fld dev stat17-7 |
0x012F0088 | fld_dev_stat17_8 | Fld dev stat17-8 |
0x012F0089 | fld_dev_stat18_1 | Fld dev stat18-1 |
0x012F008A | fld_dev_stat18_2 | Fld dev stat18-2 |
0x012F008B | fld_dev_stat18_3 | Fld dev stat18-3 |
0x012F008C | fld_dev_stat18_4 | Fld dev stat18-4 |
0x012F008D | fld_dev_stat18_5 | Fld dev stat18-5 |
0x012F008E | fld_dev_stat18_6 | Fld dev stat18-6 |
0x012F008F | fld_dev_stat18_7 | Fld dev stat18-7 |
0x012F0090 | fld_dev_stat18_8 | Fld dev stat18-8 |
0x012F0091 | fld_dev_stat19_1 | Fld dev stat19-1 |
0x012F0092 | fld_dev_stat19_2 | Fld dev stat19-2 |
0x012F0093 | fld_dev_stat19_3 | Fld dev stat19-3 |
0x012F0094 | fld_dev_stat19_4 | Fld dev stat19-4 |
0x012F0095 | fld_dev_stat19_5 | Fld dev stat19-5 |
0x012F0096 | fld_dev_stat19_6 | Fld dev stat19-6 |
0x012F0097 | fld_dev_stat19_7 | Fld dev stat19-7 |
0x012F0098 | fld_dev_stat19_8 | Fld dev stat19-8 |
0x012F0099 | fld_dev_stat20_1 | Fld dev stat20-1 |
0x012F009A | fld_dev_stat20_2 | Fld dev stat20-2 |
0x012F009B | fld_dev_stat20_3 | Fld dev stat20-3 |
0x012F009C | fld_dev_stat20_4 | Fld dev stat20-4 |
0x012F009D | fld_dev_stat20_5 | Fld dev stat20-5 |
0x012F009E | fld_dev_stat20_6 | Fld dev stat20-6 |
0x012F009F | fld_dev_stat20_7 | Fld dev stat20-7 |
0x012F00A0 | fld_dev_stat20_8 | Fld dev stat20-8 |
0x012F00A1 | fld_dev_stat21_1 | Fld dev stat21-1 |
0x012F00A2 | fld_dev_stat21_2 | Fld dev stat21-2 |
0x012F00A3 | fld_dev_stat21_3 | Fld dev stat21-3 |
0x012F00A4 | fld_dev_stat21_4 | Fld dev stat21-4 |
0x012F00A5 | fld_dev_stat21_5 | Fld dev stat21-5 |
0x012F00A6 | fld_dev_stat21_6 | Fld dev stat21-6 |
0x012F00A7 | fld_dev_stat21_7 | Fld dev stat21-7 |
0x012F00A8 | fld_dev_stat21_8 | Fld dev stat21-8 |
0x012F00A9 | fld_dev_stat22_1 | Fld dev stat22-1 |
0x012F00AA | fld_dev_stat22_2 | Fld dev stat22-2 |
0x012F00AB | fld_dev_stat22_3 | Fld dev stat22-3 |
0x012F00AC | fld_dev_stat22_4 | Fld dev stat22-4 |
0x012F00AD | fld_dev_stat22_5 | Fld dev stat22-5 |
0x012F00AE | fld_dev_stat22_6 | Fld dev stat22-6 |
0x012F00AF | fld_dev_stat22_7 | Fld dev stat22-7 |
0x012F00B0 | fld_dev_stat22_8 | Fld dev stat22-8 |
0x012F00B1 | fld_dev_stat23_1 | Fld dev stat23-1 |
0x012F00B2 | fld_dev_stat23_2 | Fld dev stat23-2 |
0x012F00B3 | fld_dev_stat23_3 | Fld dev stat23-3 |
0x012F00B4 | fld_dev_stat23_4 | Fld dev stat23-4 |
0x012F00B5 | fld_dev_stat23_5 | Fld dev stat23-5 |
0x012F00B6 | fld_dev_stat23_6 | Fld dev stat23-6 |
0x012F00B7 | fld_dev_stat23_7 | Fld dev stat23-7 |
0x012F00B8 | fld_dev_stat23_8 | Fld dev stat23-8 |
0x012F00B9 | fld_dev_stat24_1 | Fld dev stat24-1 |
0x012F00BA | fld_dev_stat24_2 | Fld dev stat24-2 |
0x012F00BB | fld_dev_stat24_3 | Fld dev stat24-3 |
0x012F00BC | fld_dev_stat24_4 | Fld dev stat24-4 |
0x012F00BD | fld_dev_stat24_5 | Fld dev stat24-5 |
0x012F00BE | fld_dev_stat24_6 | Fld dev stat24-6 |
0x012F00BF | fld_dev_stat24_7 | Fld dev stat24-7 |
0x012F00C0 | fld_dev_stat24_8 | Fld dev stat24-8 |
0x012F00C1 | fld_dev_stat25_1 | Fld dev stat25-1 |
0x012F00C2 | fld_dev_stat25_2 | Fld dev stat25-2 |
0x012F00C3 | fld_dev_stat25_3 | Fld dev stat25-3 |
0x012F00C4 | fld_dev_stat25_4 | Fld dev stat25-4 |
0x012F00C5 | fld_dev_stat25_5 | Fld dev stat25-5 |
0x012F00C6 | fld_dev_stat25_6 | Fld dev stat25-6 |
0x012F00C7 | fld_dev_stat25_7 | Fld dev stat25-7 |
0x012F00C8 | fld_dev_stat25_8 | Fld dev stat25-8 |
0x012F00C9 | ao1_out_rnge_lim | AO1 Out rnge lim |
0x012F00CA | ao2_out_rnge_lim | AO2 Out rnge lim |
0x012F00CB | ao3_out_rnge_lim | AO3 Out rnge lim |
0x012F00CC | ao4_out_rnge_lim | AO4 Out rnge lim |
0x012F00CD | ao5_out_rnge_lim | AO5 Out rnge lim |
0x012F00CE | ao6_out_rnge_lim | AO6 Out rnge lim |
0x012F00CF | ao7_out_rnge_lim | AO7 Out rnge lim |
0x012F00D0 | ao8_out_rnge_lim | AO8 Out rnge lim |
0x012F00D1 | ao9_out_rnge_lim | AO9 Out rnge lim |
0x012F00D2 | ao10_out_rnge_lim | AO10 Out rnge lim |
0x012F00D3 | ao11_out_rnge_lim | AO11 Out rnge lim |
0x012F00D4 | ao12_out_rnge_lim | AO12 Out rnge lim |
0x012F00D5 | ao13_out_rnge_lim | AO13 Out rnge lim |
0x012F00D6 | ao14_out_rnge_lim | AO14 Out rnge lim |
0x012F00D7 | ao15_out_rnge_lim | AO15 Out rnge lim |
0x012F00D8 | ao16_out_rnge_lim | AO16 Out rnge lim |
0x012F00D9 | ao17_out_rnge_lim | AO17 Out rnge lim |
0x012F00DA | ao18_out_rnge_lim | AO18 Out rnge lim |
0x012F00DB | ao19_out_rnge_lim | AO19 Out rnge lim |
0x012F00DC | ao20_out_rnge_lim | AO20 Out rnge lim |
0x012F00DD | ao21_out_rnge_lim | AO21 Out rnge lim |
0x012F00DE | ao22_out_rnge_lim | AO22 Out rnge lim |
0x012F00DF | ao23_out_rnge_lim | AO23 Out rnge lim |
0x012F00E0 | ao24_out_rnge_lim | AO24 Out rnge lim |
0x012F00E1 | ao1_in_fixed_mode | AO1 In fixed mode |
0x012F00E2 | ao2_in_fixed_mode | AO2 In fixed mode |
0x012F00E3 | ao3_in_fixed_mode | AO3 In fixed mode |
0x012F00E4 | ao4_in_fixed_mode | AO4 In fixed mode |
0x012F00E5 | ao5_in_fixed_mode | AO5 In fixed mode |
0x012F00E6 | ao6_in_fixed_mode | AO6 In fixed mode |
0x012F00E7 | ao7_in_fixed_mode | AO7 In fixed mode |
0x012F00E8 | ao8_in_fixed_mode | AO8 In fixed mode |
0x012F00E9 | ao9_in_fixed_mode | AO9 In fixed mode |
0x012F00EA | ao10_in_fixed_mode | AO10 In fixed mode |
0x012F00EB | ao11_in_fixed_mode | AO11 In fixed mode |
0x012F00EC | ao12_in_fixed_mode | AO12 In fixed mode |
0x012F00ED | ao13_in_fixed_mode | AO13 In fixed mode |
0x012F00EE | ao14_in_fixed_mode | AO14 In fixed mode |
0x012F00EF | ao15_in_fixed_mode | AO15 In fixed mode |
0x012F00F0 | ao16_in_fixed_mode | AO16 In fixed mode |
0x012F00F1 | ao17_in_fixed_mode | AO17 In fixed mode |
0x012F00F2 | ao18_in_fixed_mode | AO18 In fixed mode |
0x012F00F3 | ao19_in_fixed_mode | AO19 In fixed mode |
0x012F00F4 | ao20_in_fixed_mode | AO20 In fixed mode |
0x012F00F5 | ao21_in_fixed_mode | AO21 In fixed mode |
0x012F00F6 | ao22_in_fixed_mode | AO22 In fixed mode |
0x012F00F7 | ao23_in_fixed_mode | AO23 In fixed mode |
0x012F00F8 | ao24_in_fixed_mode | AO24 In fixed mode |
0x01310001 | inches_of_water_68_degrees_F_help | Inches of Water at 68 Degrees Fahrenheit |
0x01310002 | inches_of_mercury_0_degrees_C_help | Inches of Mercury at 0 Degrees Celsius |
0x01310003 | feet_of_water_68_degrees_F_help | Feet of Water at 68 Degrees Fahrenheit |
0x01310004 | millimeters_of_water_68_degrees_F_help | Millimeters of Water at 68 Degrees Fahrenheit |
0x01310005 | millimeters_of_mercury_0_degrees_C_help | Millimeters of Mercury at 0 Degrees Celsius |
0x01310006 | pounds_per_square_inch_help | Pounds Per Square Inch |
0x01310007 | bars_help | Bars |
0x01310008 | millibars_help | Millibars |
0x01310009 | grams_per_square_centimeter_help | Grams Per Square Centimeter |
0x0131000A | kilograms_per_square_centimeter_help | Kilograms Per Square Centimeter |
0x0131000B | pascals_help | Pascals |
0x0131000C | kilopascals_help | Kilopascals |
0x0131000D | torr_help | Torr @ 0 Degrees Celsius |
0x0131000E | atmospheres_help | Atmospheres |
0x0131000F | cubic_feet_per_minute_help | Cubic Feet Per Minute |
0x01310010 | gallons_per_minute_help | Gallons Per Minute |
0x01310011 | liters_per_minute_help | Liters Per Minute |
0x01310012 | imperial_gallons_per_minute_help | Imperial Gallons Per Minute |
0x01310013 | cubic_feet_per_hour_help | Cubic Feet Per Hour |
0x01310014 | feet_per_second_help | Feet Per Second |
0x01310015 | meters_per_second_help | Meters Per Second |
0x01310016 | gallons_per_second_help | Gallons Per Second |
0x01310017 | million_gallons_per_day_help | Million Gallons Per Day |
0x01310018 | liters_per_second_help | Liters Per Second |
0x01310019 | million_liters_per_day_help | Million Liters Per Day |
0x0131001A | cubic_feet_per_second_help | Cubic Feet Per Second |
0x0131001B | cubic_feet_per_day_help | Cubic Feet Per Day |
0x0131001C | cubic_meters_per_second_help | Cubic Meters Per Second |
0x0131001D | cubic_meters_per_day_help | Cubic Meters Per Day |
0x0131001E | imperial_gallons_per_hour_help | Imperial Gallons Per Hour |
0x0131001F | imperial_gallons_per_day_help | Imperial Gallons Per Day |
0x01310020 | degrees_celsius_help | Degrees Celsius |
0x01310021 | degrees_fahrenheit_help | Degrees Fahrenheit |
0x01310022 | degrees_rankine_help | Degrees Rankine |
0x01310023 | degrees_kelvin_help | Degrees Kelvin |
0x01310024 | millivolts_help | Millivolts |
0x01310025 | ohms_help | Ohms |
0x01310026 | hertz_help | Hertz |
0x01310027 | milliamperes_help | Milliamperes |
0x01310028 | gallons_help | Gallons |
0x01310029 | liters_help | Liters |
0x0131002A | imperial_gallons_help | Imperial Gallons |
0x0131002B | cubic_meters_help | Cubic Meters |
0x0131002C | feet_help | Feet |
0x0131002D | meters_help | Meters |
0x0131002E | barrels_help | Barrels |
0x0131002F | inches_help | Inches |
0x01310030 | centimeters_help | Centimeters |
0x01310031 | millimeters_help | Millimeters |
0x01310032 | minutes_help | Minutes |
0x01310033 | seconds_help | Seconds |
0x01310034 | hours_help | Hours |
0x01310035 | days_help | Days |
0x01310036 | centistokes_help | Centistokes |
0x01310037 | centipoise_help | Centipoise |
0x01310038 | microsiemens_help | Microsiemens |
0x01310039 | percent_help | Percent |
0x0131003A | volts_help | Volts |
0x0131003B | pH_help | pH |
0x0131003C | grams_help | Grams |
0x0131003D | kilograms_help | Kilograms |
0x0131003E | metric_tons_help | Metric Tons |
0x0131003F | pounds_help | Pounds |
0x01310040 | short_tons_help | Short Tons (2000 Pounds) |
0x01310041 | long_tons_help | Long Tons (2240 Pounds) |
0x01310042 | grams_per_second_help | Grams Per Second |
0x01310043 | grams_per_minute_help | Grams Per Minute |
0x01310044 | grams_per_hour_help | Grams Per Hour |
0x01310045 | kilograms_per_second_help | Kilograms Per Second |
0x01310046 | kilograms_per_minute_help | Kilograms Per Minute |
0x01310047 | kilograms_per_hour_help | Kilograms Per Hour |
0x01310048 | kilograms_per_day_help | Kilograms Per Day |
0x01310049 | metric_tons_per_minute_help | Metric Tons Per Minute |
0x0131004A | metric_tons_per_hour_help | Metric Tons Per Hour |
0x0131004B | metric_tons_per_day_help | Metric Tons Per Day |
0x0131004C | pounds_per_second_help | Pounds Per Second |
0x0131004D | pounds_per_minute_help | Pounds Per Minute |
0x0131004E | pounds_per_hour_help | Pounds Per Hour |
0x0131004F | pounds_per_day_help | Pounds Per Day |
0x01310050 | short_tons_per_minute_help | Short Tons (2000 Pounds) Per Minute |
0x01310051 | short_tons_per_hour_help | Short Tons (2000 Pounds) Per Hour |
0x01310052 | short_tons_per_day_help | Short Tons (2000 Pounds) Per Day |
0x01310053 | long_tons_per_hour_help | Long Tons (2240 Pounds) Per Hour |
0x01310054 | long_tons_per_day_help | Long Tons (2240 Pounds) Per Day |
0x01310055 | specific_gravity_units_help | Specific Gravity Units |
0x01310056 | grams_per_cubic_centimeter_help | Grams Per Cubic Centimeter |
0x01310057 | kilograms_per_cubic_meter_help | Kilograms Per Cubic Meter |
0x01310058 | pounds_per_gallon_help | Pounds Per Gallon |
0x01310059 | pounds_per_cubic_foot_help | Pounds Per Cubic Foot |
0x0131005A | grams_per_milliliter_help | Grams Per Milliliter |
0x0131005B | kilograms_per_liter_help | Kilograms Per liter |
0x0131005C | grams_per_liter_help | Grams Per Liter |
0x0131005D | pounds_per_cubic_inch_help | Pounds Per Cubic Inch |
0x0131005E | short_tons_per_cubic_yard_help | Short Tons (2000 Pounds) Per Cubic Yard |
0x0131005F | degrees_twaddell_help | Degrees Twaddell |
0x01310060 | degrees_brix_help | Degrees Brix |
0x01310061 | degrees_baume_heavy_help | Degrees Baume - Heavy |
0x01310062 | degrees_baume_light_help | Degrees Baume - Light |
0x01310063 | degrees_API_help | Degrees API |
0x01310064 | percent_solids_per_weight_help | Percent Solids Per Weight |
0x01310065 | percent_solids_per_volume_help | Percent Solids Per Volume |
0x01310066 | degrees_balling_help | Degrees Balling |
0x01310067 | proof_per_volume_help | Proof Per Volume |
0x01310068 | proof_per_mass_help | Proof Per Mass |
0x01310069 | bushels_help | Bushels |
0x0131006A | cubic_yards_help | Cubic Yards |
0x0131006B | cubic_feet_help | Cubic Feet |
0x0131006C | cubic_inches_help | Cubic Inches |
0x0131006D | meters_per_hour_help | Meters Per Hour |
0x0131006E | cubic_meter_per_hour_help | Cubic Meter Per Hour |
0x0131006F | cubic_meters_per_minute_help | Cubic Meters Per Minute |
0x01310070 | barrels_per_second_help | Barrels Per Second |
0x01310071 | barrels_per_minute_help | Barrels Per Minute |
0x01310072 | barrels_per_hour_help | Barrels Per Hour |
0x01310073 | barrels_per_day_help | Barrels Per Day |
0x01310074 | gallons_per_hour_help | Gallons Per Hour |
0x01310075 | imperial_gallons_per_second_help | Imperial Gallons Per Second |
0x01310076 | liters_per_hour_help | Liters Per Hour |
0x01310077 | percent_steam_quality_help | Percent Steam Quality |
0x01310079 | cubic_feet_per_pound_help | Cubic Feet Per Pound |
0x0131007A | picofarads_help | Picofarads |
0x0131007B | percent_plato_help | Percent Plato |
0x0131007C | gallons_per_day_help | Gallons Per Day |
0x0131007D | hectoliters_help | Hectoliters |
0x0131007E | megapascals_help | Megapascals |
0x0131007F | inches_of_water_4_degrees_C_help | Inches of Water at 4 Degrees Celsius |
0x01310080 | millimeters_of_water_4_degrees_C_help | Millimeters of Water at 4 Degrees Celsius |
0x01310081 | carbon_steel_help | Carbon Steel |
0x01310082 | stainless_steel_304_help | 304 Stainless Steel |
0x01310083 | stainless_steel_316_help | 316 Stainless Steel |
0x01310084 | hastelloy_c_help | Hastelloy C |
0x01310085 | monel_help | Monel |
0x01310086 | tantalum_help | Tantalum |
0x01310087 | titanium_help | Titanium |
0x01310088 | platinum_iridium_help | Platinum-Iridium |
0x01310089 | alloy_20_help | Alloy 20 |
0x0131008A | cobalt_chromium_nickel_help | Cobalt-Chromium-Nickel |
0x0131008B | ptfe_teflon_help | PTFE(Teflon) |
0x0131008C | viton_help | Viton |
0x0131008D | buna_n_help | Buna-N |
0x0131008E | ethyl_prop_help | Ethyl-Prop |
0x0131008F | urethane_help | Urethane |
0x01310091 | tefzel_help | Tefzel |
0x01310092 | ryton_help | Ryton |
0x01310093 | ceramic_help | Ceramic |
0x01310094 | stainless_steel_316l_help | 316L Stainless Steel |
0x01310095 | pvc_help | PVC |
0x01310096 | nitrile_rubber_help | Nitrile Rubber |
0x01310097 | kalrez_help | Kalrez |
0x01310098 | inconel_help | Inconel |
0x01310099 | kynar_help | Kynar |
0x0131009A | aluminum_help | Aluminum |
0x0131009B | nickel_help | Nickel |
0x0131009C | hastelloy_c_276_help | Hastelloy C 276 |
0x0131009D | monel_400_help | Monel 400 |
0x0131009E | linear_help | Linear |
0x0131009F | square_root_help | Square root |
0x013100A0 | square_root_third_power_help | Square Root to the Third Power |
0x013100A1 | square_root_fifth_power_help | Square Root to the Fifth Power |
0x013100A2 | special_curve_help | Special curve |
0x013100A3 | square_root_plus_special_curve_help | Square Root Plus Special Curve |
0x013100A4 | square_root_third_power_plus_special_curve_help | Square Root to the Third Power Plus Special Curve |
0x013100A5 | square_root_fifth_power_plus_special_curve_help | Square Root to the Fifth Power Plus Special Curve |
0x013100A6 | high_help | High |
0x013100A7 | low_help | Low |
0x013100A8 | hold_last_output_value_help | Hold Last Output Value |
0x013100A9 | analog_output_1_help | Analog Output 1 |
0x013100AA | analog_output_2_help | Analog Output 2 |
0x013100AB | analog_output_3_help | Analog Output 3 |
0x013100AC | analog_output_4_help | Analog Output 4 |
0x013100AD | bbl_liq_help | Liquid barrel |
0x013100AE | ounce_help | Ounce of weight, on Earth (Avoirdupois) |
0x013100AF | foot_pound_force_help | Foot pound force |
0x013100B0 | kilo_watt_help | Kilo watts |
0x013100B1 | kilo_watt_hour_help | Kilo watt hours |
0x013100B2 | horsepower_help | UK Horsepower (550 ft lbf/s) |
0x013100B3 | mega_calorie_help | Mega calories |
0x013100B4 | mega_joule_help | Mega Joules |
0x013100B5 | british_thermal_unit_help | British thermal unit |
0x013100B6 | normal_cubic_meter_help | Normal cubic meter (at 273.15 degrees Kelvin, 101.325 kilopascals) |
0x013100B7 | normal_liter_help | Normal liters (at 273.15 degrees Kelvin, 101.325 kilopascals) |
0x013100B8 | standard_cubic_feet_help | Cubic feet (at 32 degrees Fahrenheit, 1 Atmosphere) |
0x013100B9 | mega_calorie_per_hour_help | Mega calories per hour |
0x013100BA | mega_joule_per_hour_help | Mega Joules per hour |
0x013100BB | british_thermal_unit_per_hour_help | British thermal unit per hour |
0x013100BC | normal_cubic_meter_per_hour_help | Normal cubic meters (at 273.15 degrees Kelvin, 101.325 kilopascals) per hour |
0x013100BD | normal_liter_per_hour_help | Normal liters (at 273.15 degrees Kelvin, 101.325 kilo pascals)per hour |
0x013100BE | standard_cubic_feet_per_minute_help | Cubic feet (at 32 degrees Fahrenheit, 1 Atmosphere) per minute |
0x013100BF | deka_therm_help | Deka therm. |
0x013100C0 | parts_per_million_help | Parts per million |
0x013100C1 | fep_help | Perfluoraethylenpropylene |
0x013100C2 | stainless_steel_316_ti_help | 316 Stainless steel Ti, 16-18% Chromium, 10-14% Nickel, 2-3% Molybdan |
0x013100C3 | rs_232_help | Standards designation |
0x013100C4 | gold_monel_help | Gold monel alloy |
0x013100C5 | milli_siemens_per_centimeter_help | milli siemens per centimeter |
0x013100C6 | kohms_help | Kilo ohms |
0x013100C7 | klinger_c4401_help | 4401- Material that may be referenced by Klinger compound No. C4401 |
0x013100C8 | thermotork_help | Thermotork- Material trademarked by Armstrong World Industries Inc. |
0x013100C9 | grafoil_help | Grafoil- Material trademarked by Union Carbide |
0x013100CA | ptfe_coated_316l_sst_help | Poly Tetra Fluoro Ethylene coated 316L Stainless steel- Material, PTFE is also known by the trademark name Teflon |
0x013100CB | gold_plated_hastelloy_c276_help | Gold plated Hastelloy C276- Material |
0x013100CC | ptfe_graphite_help | Poly Tetra Fluoro Ethylene Graphite- Material, Graphite filled PTFE, PTFE is also known by the trademark name Teflon |
0x013100CD | ptfe_glass_help | Poly Tetra Fluoro Ethylene Glass- Material, Glass filled PTFE, PTFE is also known by the trademark name Teflon |
0x013100CE | micro_siemens_per_centimeter_help | Micro siemens per centimeter |
0x013100CF | newton_help | Newton- Unit of force |
0x013100D0 | newton_meter_help | Newton meter- Unit for torque |
0x013100D1 | inches_per_second_help | Inches per Second- Unit for speed |
0x013100D2 | inches_per_minute_help | Inches per minute- Unit for speed |
0x013100D3 | feet_per_minute_help | Feet per Minute- Unit for speed |
0x013100D4 | degrees_per_second_help | Degrees per Second- Unit for angular frequency |
0x013100D5 | revolutions_per_minute_help | Revolutions per Minute- Unit for rotation |
0x013100D6 | degrees_help | Degrees- Unit of angular measurement |
0x013100D7 | revolutions_per_second_help | Revolutions per Second- Unit for rotation |
0x013100D8 | square_help | Square |
0x013100D9 | PTFE_hastelloy_help | Poly Tetra Fluoro Ethylene/Hastelloy- Type of O-Ring material, known as Turcon Variseal H. |
0x013100DA | stainless_steel_CF_8M_help | Stainless Steel CF-8M |
0x013100DB | hastelloy_sst_help | Hastelloy C/Stainless Steel |
0x013100DC | gold_plated_sst_help | Gold Plated Stainless Steel |
0x013100DD | radian_help | Radian- Unit of angular measurement |
0x013100DE | inches_of_water_60_degrees_F_help | Inches of Water at 60 Degrees Fahrenheit |
0x013100DF | ug_l_help | Micrograms per Liter |
0x013100E0 | ug_m3_help | Micrograms per Cubic Meter |
0x013100E1 | percent_consistency_help | Percent Consistency |
0x013100E2 | volume_percent_help | Volume Percent |
0x013100E3 | ml_l_help | Mililiters per Liter |
0x013100E4 | ul_l_help | Microliters per Liter |
0x013100E5 | percent_lel_help | Percent Lower Explosion Level |
0x013100E6 | ppb_help | Parts per Billion |
0x013100E7 | discrete_switch_help | Discrete (Switch)- binary on/off |
0x013100E8 | aflas_help | Aflas |
0x01900003 | default_label | No Label Available |
0x01910001 | hart_block_label | |
0x332C0001 | mmi_event1_label | Event 1 |
0x332C000A | mmi_event2_label | Event 2 |
0x332C0022 | mmi_sv_ao_cutoff_label | SV AO cutoff |
0x332C002B | mmi_ref_temp_label | Ref temperature |
0x332C002C | mmi_k1_label | K1 |
0x332C002D | mmi_k2_label | K2 |
0x332C002F | mmi_alarm_num_label | Event num |
0x332C0039 | mmi_pulses_unit_label | Pulses/Unit |
0x332C003A | mmi_units_pulse_label | Units/Pulse |
0x332C003E | mmi_dens_tgco_label | DTG |
0x332C003F | mmi_dens_fqco1_label | DFQ1 |
0x332C0040 | mmi_dens_fqco2_label | DFQ2 |
0x332C0041 | mmi_flow_tgco_label | FTG |
0x332C0042 | mmi_flow_fqco_label | FFQ |
0x332C0046 | mmi_value_label | Value |
0x332C0048 | mmi_low_alarm_label | Low Alarm |
0x332C006E | mmi_dt_label | DT |
0x332C0072 | mmi_tube_freq_var_label | Tube Frequency |
0x332C0073 | mmi_drive_gain_var_label | Drive Gain |
0x332C0075 | mmi_board_temp_var_label | Board Temperature |
0x332C0076 | mmi_input_voltage_var_label | Input Voltage |
0x332C0077 | mmi_abs_val_label | Absolute Value |
0x332C0079 | mmi_scaled_dac_label | Scaled AO1 trim |
0x332C007E | mmi_polling_labl_2 | Poll Control 2 |
0x332C0081 | mmi_poll_type_label | Polling Type |
0x332C0082 | mmi_iso_brd_label | IS Output |
0x332C0084 | mmi_do_assign_label | DO is |
0x332C0085 | mmi_do_index_label | DO index |
0x332C0086 | mmi_chana_assign_label | Channel A |
0x332C0087 | mmi_chanb_assign_label | Channel B |
0x332C0088 | mmi_chanc_assign_label | Channel C |
0x332C0089 | mmi_ao2_fault_setup_label | AO2 Fault Setup |
0x332C0090 | mmi_drive_value_unit | Drive unit |
0x332C0091 | mmi_do1_setup_label | DO1 Setup |
0x332C0093 | mmi_api_ctl_label | CTL |
0x332C0094 | mmi_ext_temperature_label | External Temperature |
0x332C0096 | mmi_table_5a | Table 5A |
0x332C0097 | mmi_table_5b | Table 5B |
0x332C0098 | mmi_table_5d | Table 5D |
0x332C0099 | mmi_table_6c | Table 6C |
0x332C009A | mmi_table_23a | Table 23A |
0x332C009B | mmi_table_23b | Table 23B |
0x332C009C | mmi_table_23d | Table 23D |
0x332C009D | mmi_table_24c | Table 24C |
0x332C009E | mmi_table_53a | Table 53A |
0x332C009F | mmi_table_53b | Table 53B |
0x332C00A0 | mmi_table_53d | Table 53D |
0x332C00AA | mmi_di_assign_label | DI is |
0x332C00AB | mmi_di_index_label | DI index |
0x332C00AC | mmi_di1_setup_label | DI1 Setup |
0x332C00B2 | mmi_external_label | External |
0x332C00B3 | mmi_internal_label | Internal |
0x332C00B4 | mmi_do2_setup_label | DO2 Setup |
0x332C00B5 | mmi_do1_assign_label | DO 1 is |
0x332C00B7 | mmi_polarity_label | Polarity |
0x332C00B8 | mmi_active_high_label | Active High |
0x332C00B9 | mmi_active_low_label | Active Low |
0x332C00BB | mmi_static_pressure_label | Static Pressure |
0x332C00BC | mmi_enable_api_label | Enable API |
0x332C00BE | mmi_static_temp_label | Static Temperature |
0x332C00C0 | mmi_cfg_brd_label | Config I/O |
0x332C00C1 | mmi_table_54c | Table 54C |
0x332C00C2 | mmi_fwd_rev | Forward/Reverse |
0x332C00C4 | mmi_power_label | Power Source |
0x332C00CA | mmi_pc1_label | Discrete Event 1 |
0x332C00CB | mmi_pc2_label | Discrete Event 2 |
0x332C00CC | mmi_pc3_label | Discrete Event 3 |
0x332C00CD | mmi_pc4_label | Discrete Event 4 |
0x332C00CE | mmi_pc5_label | Discrete Event 5 |
0x332C00CF | mmi_pc_num_label | Discrete Event num |
0x332C00D0 | mmi_pc_setpointA_label | Setpoint A |
0x332C00D1 | mmi_pc_setpointB_label | Setpoint B |
0x332C00E7 | mmi_di2_setup_label | DI2 Setup |
0x332C00EF | mmi_2500_cfg_brd_label | 2500 Config I/O |
0x332C00F0 | mmi_3500_brd_label | 3000 |
0x332C00F2 | mmi_discrete_action_code_label | Discrete Action |
0x332C00F3 | mmi_discrete_assign_code_label | Discrete Assignment |
0x332C00F4 | mmi_choose_discrete_action | Choose Action: |
0x332C00F6 | mmi_choose_discrete_assignment | Choose Discrete: |
0x332C00F9 | mmi_alarm_information_label | info |
0x332C00FA | mmi_alarm_fault_label | fault |
0x332C00FB | mmi_alarm_ignore_label | ignore |
0x332C00FC | mmi_di_1_polarity_label | DI 1 Polarity |
0x332C00FD | mmi_di_2_polarity_label | DI 2 Polarity |
0x332C0104 | mmi_start_sensor_zero_label | Start Sensor Zero |
0x332C0105 | mmi_start_stop_totals_label | Start/Stop Totals |
0x332C010A | mmi_neg_forward_only_label | Negate/Forward Only |
0x332C010B | mmi_neg_bidir_label | Negate/Bi-Directional |
0x332C0111 | mmi_num_preambles_label | Num Preambles |
0x332C011A | mmi_fkey_custody_transfer_label | Custody Transfer |
0x332C011C | mmi_feature_key_label | Features |
0x332C012E | mmi_do_1_polarity_label | DO 1 Polarity |
0x332C0137 | mmi_ao1cut_label | AO1 Cutoff |
0x332C0138 | mmi_input_Voltage | Input Voltage |
0x332C0139 | mmi_gas_Standard_Volume_Flow_label | Gas Vol flo |
0x332C013D | mmi_faultcode_label | fault code |
0x332C013E | mmi_faultlevel_label | fault level |
0x332C013F | di_fault_setup_label | DI Fault Setup |
0x332C0140 | do_fault_setup_label | DO Fault Setup |
0x332C0141 | mmi_Actual_Target_Amplitude_label | Act Target Amplitude |
0x332C0142 | mmi_Average_sensor_temp_label | Avg Sensor Temp |
0x332C0143 | mmi_Minimum_sensor_temp_label | Min Sensor Temp |
0x332C0144 | mmi_Maximum_sensor_temp_label | Max Sensor Temp |
0x332C0145 | mmi_Average_electronics_temp_label | Avg Elect Temp |
0x332C0146 | mmi_Minimum_electronics_temp_label | Min Elect Temp |
0x332C0147 | mmi_Wire_RTD_resistance_label | Wire RTD |
0x332C0148 | mmi_Meter_RTD_resistance_label | Meter RTD |
0x332C0149 | mmi_Line_RTD_resistance_label | Line RTD |
0x332C014A | mmi_Power_cycle_count_label | Power cycle count |
0x332C014B | mmi_Power_on_time_label | Power on time |
0x332C014C | flow_switch_variable_assignment_label | Flow Switch Variable Assignment |
0x332C014D | mmi_do_1_FaultIndication_label | DO Fault Indication |
0x332C014E | modbus_Mode_label | Modbus Mode |
0x332C0150 | Alarm_Status_label | Alarm Status |
0x332C0151 | varCount_label | Count |
0x332C0152 | Last_Posted | Last Posted |
0x332C0153 | Last_Cleared | Last Cleared |
0x332C0154 | varMODBUS_Data_Type_Code_label | Modbus Data Type Code |
0x332C0156 | varCoil_Number_label | Coil Number or Starting Register Address |
0x332C0157 | varCoil_Value_label | Coil Value |
0x332C0158 | varEnable_TBR_label | Enable TBR |
0x332C0159 | varTBR_Threshold_label | TBR Threshold |
0x332C015A | varTBR_Timeout_label | TBR Timeout |
0x332C015B | varTBR_Last_Measured_Value_label | TBR Last Measured Value Sample Position |
0x332C015D | varGas_Density_label | Gas Density |
0x332C0174 | varDiagnostic_Action_Code_LABEL | Diagnostic Action |
0x332C0176 | Status_Change_LABEL | Status Change |
0x332C0177 | Timestamp_of_status_change_LABEL | Timestamp of status change |
0x332C0178 | gas_vol_flow_digital_units_LABEL | Gas Vol flo unit |
0x332C0179 | gas_vol_flow_digital_cutoff_LABEL | Gas Vol flo Cutoff |
0x332C017A | gas_vol_flow_analog_value_LABEL | Gas Vol flo |
0x332C017B | gas_std_vtot_digital_units_LABEL | Gas Vol flo tot inv unit |
0x332C017C | live_zero_digital_units_LABEL | Live Zero unit |
0x332C017E | input_volt_digital_units_LABEL | Input voltage unit |
0x332C01DC | Word_420_LABEL | Status Word 420 |
0x332C01DD | Word_419_LABEL | Status Word 419 |
0x332C01DE | Word_422_LABEL | Status Word 422 |
0x332C01DF | Word_421_LABEL | Status Word 421 |
0x332C01E0 | Word_424_LABEL | Status Word 424 |
0x332C01E1 | Word_423_LABEL | Status Word 423 |
0x332C01E2 | Word_433_LABEL | Status Word 433 |
0x332C01E3 | Word_434_LABEL | Status Word 434 |
0x332C01E5 | mmi_polling_labl | Poll Control |
0x332C01E7 | word_419_desc_label | Reads Modbus register no. 419 |
0x332C01E8 | word_420_desc_label | Reads Modbus register no. 420 |
0x332C01E9 | word_421_desc_label | Reads Modbus register no. 421 |
0x332C01EA | word_422_desc_label | Reads Modbus register no. 422 |
0x332C01EB | word_423_desc_label | Reads Modbus register no. 423 |
0x332C01EC | word_424_desc_label | Reads Modbus register no. 424 |
0x332C01ED | word_433_desc_label | Reads Modbus register no. 433 |
0x332C01EE | word_434_desc_label | Reads Modbus register no. 434 |
0x332C01F6 | enable_meter_verification_label | Enable meter verification |
0x332C01F7 | output_state_meter_verification_label | Ouput state during meter verification |
0x332C01F8 | mmi_abort_code_label | Abort code |
0x332C01F9 | mmi_current_algorithm_state_abort_label | Current Algorithm State |
0x332C01FA | mmi_validation_counter_label | Validation counter |
0x332C01FB | mmi_LPO_stiffness_out_of_limits_label | LPO stiffness out of limits |
0x332C01FC | mmi_RPO_stiffness_out_of_limits_label | RPO stiffness out of limits |
0x332C01FD | mmi_current_LPO_stiffness_mean_label | Current LPO stiffness (Mean) |
0x332C01FE | mmi_current_RPO_stiffness_mean_label | Current RPO stiffness (Mean) |
0x332C01FF | mmi_algorithm_progress_label | Algorithm progress |
0x332C0208 | stiffness_limit_set_point_label | Stiffness Limit Set Point |
0x332C0209 | mmi_current_damping_mean_label | Current Damping (Mean) |
0x332C020A | mmi_current_LPO_mass_mean_label | Current LPO Mass (Mean) |
0x332C020B | mmi_current_RPO_mass_mean_label | Current RPO Mass (Mean) |
0x332C020C | mmi_current_LPO_stiffness_std_dev_label | Current LPO Stiffness (Std Dev) |
0x332C020D | mmi_current_RPO_stiffness_std_dev_label | Current RPO Stiffness (Std Dev) |
0x332C020E | mmi_current_damping_std_dev_label | Current Damping (Std Dev) |
0x332C020F | mmi_current_LPO_mass_std_dev_label | Current LPO Mass (Std Dev) |
0x332C0210 | mmi_current_RPO_mass_std_dev_label | Current RPO Mass (Std Dev) |
0x332C0211 | mmi_LPO_stiffness_fact_cali_air_mean_label | LPO Stiffness (Mean), Fact. Calib of Air |
0x332C0212 | mmi_RPO_stiffness_fact_cali_air_mean_label | RPO Stiffness (Mean), Fact. Calib of Air |
0x332C0213 | mmi_damping_fact_cali_air_mean_label | Damping (Mean), Fact. Calib of Air |
0x332C0214 | mmi_LPO_mass_fact_cali_air_mean_label | LPO Mass, Fact. Calib of Air |
0x332C0215 | mmi_RPO_mass_fact_cali_air_mean_label | RPO Mass, Fact. Calib of Air |
0x332C0216 | mmi_LPO_stiffness_fact_cali_water_mean_label | LPO Stiffness (Mean), Fact. Calib of Water |
0x332C0217 | mmi_RPO_stiffness_fact_cali_water_mean_label | RPO Stiffness (Mean), Fact. Calib of Water |
0x332C0218 | mmi_damping_fact_cali_water_mean_label | Damping (Mean), Fact. Calib of Water |
0x332C0219 | mmi_LPO_mass_fact_cali_water_mean_label | LPO Mass, Fact. Calib of Water |
0x332C021A | mmi_RPO_mass_fact_cali_water_mean_label | RPO Mass, Fact. Calib of Water |
0x332C021E | mmi_do_2_FaultIndication_3000_label | DO 2 Fault Indication |
0x332C0224 | mmi_modbus_data_label | Modbus Data |
0x332C0227 | mmi_clock_hours_label | Hours |
0x332C022C | mmi_meter_verification_dataset_label | Meter Verification Dataset |
0x332C022D | mmi_meter_verification_mean | Meter Verification Dataset Mean |
0x332C022E | mmi_meter_verification_std_dev | Meter Verification Dataset Satndard Deviation |
0x332C022F | mmi_fact_cali_air_means | Factory Cal of Air Means |
0x332C0230 | mmi_fact_cali_water_means | Factory Cal of Water Means |
0x332C0231 | mmi_running_avg_data | Running Average Data |
0x332C0232 | mmi_std_error_estimate | Standard Error of Estimate |
0x332C0233 | mmi_dataset_LPO_stiffness_label | Dataset LPO Stiffness |
0x332C0234 | mmi_dataset_RPO_stiffness_label | Dataset RPO Stiffness |
0x332C0235 | mmi_dataset_damping_label | Dataset damping |
0x332C0236 | mmi_dataset_LPO_mass_label | Dataset LPO Mass |
0x332C0237 | mmi_dataset_RPO_mass_label | Dataset RPO Mass |
0x332C0243 | mmi_alarm_severity_label_2 | Alarm Severity |
0x332C0245 | alarm_event_log_index_label | Alarm Event Log Index |
0x332D0005 | mmi_ev1_stat_label | Status Event1 |
0x332D0006 | mmi_ev2_stat_label | Status Event2 |
0x332D0010 | mmi_str_enter_dens | Enter Density |
0x332D0012 | mmi_str_prob_detected | A problem was detected |
0x332D0013 | mmi_str_abort_fix_retry | Abort;Fix and Retry |
0x332D0015 | mmi_str_perform_cal | Perform calibration? |
0x332D0019 | mmi_str_freq_choice | 10 kHz;Other;End |
0x332D001B | mmi_str_abort_error | Aborting due to field device error |
0x332D001E | mmi_str_anal_choice | 4 mA;20 mA;Other;End |
0x332D001F | mmi_str_out_level | Output value: |
0x332D0023 | mmi_str_conn_ref | Connect reference meter |
0x332D0026 | mmi_str_ao1_to_n | About to set analog output 1 to %0 mA |
0x332D0027 | mmi_str_ao2_to_n | About to set analog output 2 to %0 mA |
0x332D002B | mmi_str_yes_no | Yes;No |
0x332D0033 | mmi_str_unit_msg | NOTE-Variables which use this as the units code will be in the previous units until this value is sent to the device |
0x332D0035 | mmi_str_fo_scaling_msg | NOTE-Send scaling method selection to the device prior to performing frequency output scaling. |
0x332D0036 | mmi_str_fd_cal_minimum | NOTE: Flow rate must be greater than 50% of the nominal flow for the meter. |
0x332D0037 | mmi_str_sens_type_choice | T-Series;Other |
0x332D0038 | mmi_str_sens_type | Sensor type: |
0x332D003F | mmi_str_do_choice | Off;On;End |
0x332D004A | mmi_str_fault_level_msg | NOTE-When selecting upscale or downscale,configure fault value before sending fault code to the device. |
0x332D004D | mmi_api_table_number_choice | 5;6;23;24;53;54 |
0x332D004E | mmi_api_table_letter_choice | A;B;D |
0x332D004F | mmi_str_enter_tec | Enter Thermal Expansion Coefficient |
0x332D0050 | mmi_str_enter_ref_temp | Enter Reference Temperature in degC |
0x332D0063 | mmi_str_discrete_assignment | %0 is assigned to %1 |
0x332D006F | perform_varDiagnostic_Action_Code_label4 | Action code was performed |
0x332D0071 | modbus_selection_data_type_label | Selection for data type |
0x332D0072 | modbus_choose_data_type_label | Coil;Unsigned 16;Unsigned 32;Floating Point;Exit |
0x332D0073 | read_modbus_register_label4 | Enter Coil Number |
0x332D0074 | read_modbus_register_label5 | Enter Register Number |
0x332D0076 | select_on_on_label | off;on |
0x332D0077 | enter_u16_label | Enter Unsigned 16 Value |
0x332D0078 | enter_u32_label | Enter Unsigned 32 Value |
0x332D0079 | enter_fp_label | Enter Floating Point Value |
0x332D007D | mmi_select_mode_sim | Select the Simulation Mode |
0x332D007E | write_simulation_params_massflow_label5 | Fixed Value;Triangular Wave;Sine Wave |
0x332D007F | write_simulation_params_massflow_label6 | Enter Mass Flow Fixed Value |
0x332D0080 | write_simulation_params_massflow_label7 | Enter Mass Flow Minimum Amplitude of waveform |
0x332D0081 | write_simulation_params_massflow_label8 | Enter Mass Flow Maximum Amplitude of waveform |
0x332D0082 | write_simulation_params_massflow_label9 | Enter Mass Flow period of waveform in second. |
0x332D0084 | write_simulation_params_temp_label2 | Enter Temperature Fixed Value |
0x332D0085 | write_simulation_params_temp_label3 | Enter Temperature Minimum Amplitude of waveform |
0x332D0086 | write_simulation_params_temp_label4 | Enter Temperature Maximum Amplitude of waveform |
0x332D0087 | write_simulation_params_temp_label5 | Enter Temperature period of waveform in second. |
0x332D0089 | write_simulation_params_Density_label2 | Enter Density Fixed Value |
0x332D008A | write_simulation_params_Density_label3 | Enter Density Minimum Amplitude of waveform |
0x332D008B | write_simulation_params_Density_label4 | Enter Density Maximum Amplitude of waveform |
0x332D008C | write_simulation_params_Density_label5 | Enter Density period of waveform in second. |
0x332D008E | mmi_discrete_action_choices_2400_label | Start Sensor Zero;Reset Mass Total;Reset Volume Total;Reset Gas Standard Volume Total;Reset All Totals;Start/Stop Totals |
0x332D008F | mmi_discrete_assignment_choices_label2 | None;Discrete Event 1;Discrete Event 2;Discrete Event 3;Discrete Event 4;Discrete Event 5;DI 1 |
0x332D0094 | mmi_select_OPstate | Last Value;Fault |
0x332D0096 | mmi_stiffness_label | Stiffness setpoint (percentage): |
0x332D0097 | mmi_meter_verification | Meter Verification |
0x332D009A | mmi_Meter_Veri_abort | Aborting verification...! |
0x332D009D | mmi_OPLabel_new_label | Select output behavior: |
0x332D00A3 | mmi_stiffness_value_default_label | 0.1;0.5;1.0;2.0;3.0;4.0;5.0 |
0x332E0000 | mmi_pv_hot_rerange_label | Anlog 1 range vals |
0x332E0002 | mmi_pv_range_label | Anlog 1 range vals |
0x332E0015 | mmi_density_char_label | Density |
0x332E0016 | mmi_flow_vars_label | Flow |
0x332E0017 | mmi_dens_vars_label | Density |
0x332E0018 | mmi_temp_vars_label | Temperature |
0x332E0025 | mmi_upload_variables_label | Write variables |
0x332E0026 | mmi_dencal_a_label | Dens Pt1 (Air) |
0x332E0027 | mmi_dencal_b_label | Dens Pt2 (Water) |
0x332E0030 | mmi_reset_mass_total_label | Reset mass total |
0x332E0031 | mmi_reset_vol_total_label | Reset volume total |
0x332E0035 | mmi_d1_label | D1 |
0x332E0036 | mmi_d2_label | D2 |
0x332E0037 | mmi_dencal_fd_label | Flowing Dens (FD) |
0x332E0039 | mmi_d3_label | D3 |
0x332E003A | mmi_d4_label | D4 |
0x332E003B | mmi_k3_label | K3 |
0x332E003C | mmi_k4_label | K4 |
0x332E003D | mmi_dencal_c_label | Dens Pt3 T-series |
0x332E003E | mmi_dencal_d_label | Dens Pt4 T-series |
0x332E0042 | mmi_sens_setup_meth_label | Sensor Selection |
0x332E0047 | mmi_reset_corr_vol_total_label | Reset corrected volume total |
0x332E0052 | mmi_reset_totals_label | Reset totals |
0x332E0079 | mmi_batch_to_label | Batch Timeout |
0x332E0098 | Gas_volume_standard_setup_label | Gas Standard Volume |
0x332E00A1 | display_vars_label | Display Variables |
0x332E00A5 | mmi_status | Status |
0x332E00A7 | mmi_maint | Maintenance |
0x332E00AA | mmi_drive_gain | Drive Gain |
0x332E00AB | mmi_dens | Density |
0x332E00AD | mmi_prim_var | Primary Variable |
0x332E00B7 | mmi_2nd_variable | 2nd Variable |
0x332E00B9 | mmi_3rd_variable | 3rd Variable |
0x332E00BB | mmi_4th_variable | 4th Variable |
0x332E00BD | mmi_totalizers | Totalizers |
0x332E00BE | mmi_mass | Mass |
0x332E00BF | mmi_volume | Volume |
0x332E00C0 | mmi_all_totalizers | All Totalizers |
0x332E00C2 | mmi_inv | Inventory |
0x332E00C4 | mmi_vars | Variables |
0x332E00C6 | mmi_display | Display |
0x332E00CB | mmi_temp | Temperature |
0x332E00CC | mmi_press | Pressure |
0x332E00CF | mmi_sensor | Sensor |
0x332E00D1 | mmi_special_units | Special Units |
0x332E00D2 | mmi_mass_spec_units | Mass Special Units |
0x332E00D3 | mmi_vol_spec_units | Volume Special Units |
0x332E00D9 | mmi_discrete_ip | Discrete Input |
0x332E00DC | mmi_freq | Frequency |
0x332E00DD | mmi_var_mapping | Variable Mapping |
0x332E00DF | mmi_discrete_op | Discrete Output |
0x332E00E1 | mmi_discrete_events | Discrete Events |
0x332E00E2 | mmi_discrete_event1 | Discrete Event 1 |
0x332E00E3 | mmi_discrete_event2 | Discrete Event 2 |
0x332E00E4 | mmi_discrete_event3 | Discrete Event 3 |
0x332E00E5 | mmi_discrete_event4 | Discrete Event 4 |
0x332E00E6 | mmi_discrete_event5 | Discrete Event 5 |
0x332E00E9 | mmi_proc_charts | Process Charts |
0x332E00EA | mmi_secondary_var | Secondary Variable |
0x332E00EB | mmi_tertiary_var | Tertiary Variable |
0x332E00EC | mmi_quarternary_var | Quarternary Variable |
0x332E00ED | mmi_primary_op | Primary Output |
0x332E0113 | mmi_secondary_op | Secondary Output |
0x332F0011 | mmi_tube_freq_label | Tube |
0x332F0015 | mmi_live_zero_label | Live zero flow |
0x332F0017 | mmi_fd_label | FD |
0x332F001A | mmi_halar_label | Halar |
0x332F001B | mmi_disabled_label | Disabled |
0x332F001C | mmi_enabled_label | Enabled |
0x332F001D | mmi_modbus_rtu_label | Modbus RTU |
0x332F001E | mmi_modbus_ascii_label | Modbus ASCII |
0x332F001F | mmi_b_1200_label | 1200 |
0x332F0020 | mmi_b_2400_label | 2400 |
0x332F0021 | mmi_b_4800_label | 4800 |
0x332F0022 | mmi_b_9600_label | 9600 |
0x332F0023 | mmi_b_19200_label | 19200 |
0x332F0024 | mmi_b_38400_label | 38400 |
0x332F0025 | mmi_odd_label | Odd |
0x332F0026 | mmi_even_label | Even |
0x332F0027 | mmi_ma_prim_label | mA Output 1 |
0x332F002B | mmi_output_type_label | Output Type |
0x332F002C | mmi_high_alarm_label | High Alarm |
0x332F0034 | mmi_NAN_label | Not-a-Number |
0x332F0035 | mmi_analog_io_brd_label | Analog I/O |
0x332F0036 | mmi_fieldbus_brd_label | Fieldbus (H1) |
0x332F0039 | mmi_pv | PV |
0x332F003E | mmi_SGU | SGU |
0x332F0040 | mmi_tag | Tag |
0x332F0041 | mmi_units | Unit |
0x332F0048 | mmi_upscale | Upscale |
0x332F0049 | mmi_downscale | Downscale |
0x332F004A | mmi_off | Off |
0x332F004B | mmi_on | On |
0x332F004E | mmi_100hz | Special |
0x332F004F | mmi_dens_pres_factor_unit_label | g/Cucm per psi |
0x332F0050 | mmi_flow_pres_factor_unit_label | % per psi |
0x332F0053 | mmi_flow_switch | Flow Switch |
0x332F005E | mmi_ext_temperature_digital_value | External Temperature |
0x332F0061 | mmi_density_cutoff | Dens Cutoff |
0x332F006B | mmi_gt_setpointA_label | > Setpoint A |
0x332F006C | mmi_lt_setpointA_label | < Setpoint A |
0x332F006D | mmi_inrange_label | In Range |
0x332F006E | mmi_outrange_label | Out of Range |
0x332F0075 | mmi_ed_net_volume_inventory_digital_value | ED Net Vol inv |
0x332F0078 | mmi_ed_std_volume_inventory_digital_value | ED Std Vol inv |
0x332F007C | mmi_ed_dens_sgu_digital_value | ED Dens (SGU) |
0x332F007D | mmi_ed_dens_baume_digital_value | ED Dens (Baume) |
0x332F0082 | mmi_reset_mass_total_only_label | Reset Mass Total |
0x332F0083 | mmi_reset_vol_total_only_label | Reset Vol Total |
0x332F008F | extended_device_status_codes_mmi1 | Maintenance Required |
0x332F0090 | extended_device_status_codes_mmi2 | Device Variable Alert |
0x332F0091 | mmi_gsvf_label | Gas Standard Volume Flow |
0x332F0092 | mmi_gsvt_label | Gas Standard Volume Total |
0x332F0093 | mmi_gsvi_label | Gas Standard Volume Inventory |
0x332F0096 | mmi_brd_8_label | 800 |
0x332F0097 | mmi_brd_alabel | 2400S Analog |
0x332F0098 | mmi_brd_ff_label | 2400S FOUNDATION Fieldbus |
0x332F0099 | mmi_brd_dn_label | 2400S DeviceNet |
0x332F009A | mmi_brd_dp_label | 2400S Profibus DP |
0x332F009E | mmi_asciirtu_label | ASCII and RTU |
0x332F009F | mmi_rtuonly_label | RTU Only |
0x332F00A4 | mmi_reset_gas_vol_total_label | Reset Gas Standard Volume Total |
0x332F00A5 | mmi_NoSim | No Sim |
0x332F00A6 | mmi_FixedValue | Fixed Value |
0x332F00A7 | mmi_TriangularWave | Triangular Wave |
0x332F00A8 | mmi_SineWave | Sine Wave |
0x332F00A9 | mmi_None | None |
0x332F00AA | mmi_ResetAlarmLog | Reset Alarm Log |
0x332F00AB | mmi_AcknowledgeAllAlarms | Acknowledge All Alarms |
0x332F00AC | mmi_ResetPowerOnTime | Reset Power On Time |
0x332F00AD | mmi_RestoreFactoryConfiguration | Restore Factory Configuration |
0x332F00B1 | Word_420_enum_Bit0 | Primary mA Output Saturated |
0x332F00B2 | Word_420_enum_Bit1 | Secondary mA Output Saturated |
0x332F00B3 | Word_420_enum_Bit2 | Primary mA Output Fixed |
0x332F00B4 | Word_420_enum_Bit3 | Secondary mA Output Fixed |
0x332F00B5 | Word_420_enum_Bit4 | Density Outside Limits |
0x332F00B7 | Word_420_enum_Bit6 | PIC/Daughterboard Communication Failure |
0x332F00B8 | Word_420_enum_Bit7 | External Input Failure |
0x332F00B9 | Word_420_enum_Bit8 | Core EEPROM Checksum Error (Config, Powerdown, Program) |
0x332F00BA | Word_420_enum_Bit9 | Core RAM Error |
0x332F00BB | Word_420_enum_Bit10 | Sensor Not Responding (No Tube Interrupt) |
0x332F00BC | Word_420_enum_Bit11 | Temperature Sensor Out-of-Range |
0x332F00BD | Word_420_enum_Bit12 | Input Over-Range |
0x332F00BE | Word_420_enum_Bit13 | Frequency Output Saturated |
0x332F00BF | Word_420_enum_Bit14 | Transmitter Not Characterized (Flocal or Sensor Type) |
0x332F00C0 | Word_420_enum_Bit15 | Real-Time Interrupt Failure |
0x332F00C1 | Word_419_enum_Bit0 | Core EEPROM Checksum Error (Config, Powerdown, Program) |
0x332F00C2 | Word_419_enum_Bit1 | Core RAM Test Error |
0x332F00C3 | Word_419_enum_Bit2 | Real-Time Interrupt Failure |
0x332F00C4 | Word_419_enum_Bit3 | Sensor Failure |
0x332F00C5 | Word_419_enum_Bit4 | Temperature Sensor Out-of-Range |
0x332F00C6 | Word_419_enum_Bit5 | Calibration Failure (Autozero, Density, Temperature) |
0x332F00C7 | Word_419_enum_Bit6 | Other Failure |
0x332F00C8 | Word_419_enum_Bit7 | Transmitter Initializing/Warming Up |
0x332F00C9 | Word_419_enum_Bit8 | PV Out-Of-Limits |
0x332F00CA | Word_419_enum_Bit9 | Non-PV Out-Of-Limits |
0x332F00CB | Word_419_enum_Bit10 | Simulation Mode Active (A132) |
0x332F00CC | Word_419_enum_Bit11 | Undefined |
0x332F00CD | Word_419_enum_Bit12 | Watchdog Error |
0x332F00CE | Word_419_enum_Bit13 | Cold Start (HART bit) |
0x332F00CF | Word_419_enum_Bit14 | Transmitter Configuration Changed (HART bit) |
0x332F00D0 | Word_419_enum_Bit15 | Fault (Failure has occurred which affects accuracy) |
0x332F00D1 | Word_422_enum_Bit0 | API.VCF: Temperature Outside Standard Range |
0x332F00D2 | Word_422_enum_Bit1 | API.VCF:Line Density Outside Standard Range |
0x332F00D3 | Word_422_enum_Bit2 | Line RTD Temperature Out-Of-Range |
0x332F00D4 | Word_422_enum_Bit3 | Meter RTD Temperature Out-Of-Range |
0x332F00D5 | Word_422_enum_Bit4 | Flow Direction (0=Forward/Zero,1=Reverse) |
0x332F00D6 | Word_422_enum_Bit5 | Factory Configuration Data Is Invalid |
0x332F00D7 | Word_422_enum_Bit6 | Enhanced Density: Unable to fit curve data |
0x332F00D8 | Word_422_enum_Bit7 | Last Measured Value Override Active |
0x332F00D9 | Word_422_enum_Bit8 | Enhanced Density Extrapolation Alarm |
0x332F00DA | Word_422_enum_Bit9 | Cal Factors Unentered (Flocal Mandatory) |
0x332F00DB | Word_422_enum_Bit10 | 1000/2000/3000 EEPROM Checksum Error |
0x332F00DC | Word_422_enum_Bit11 | 1000/2000/3000 RAM Test Error |
0x332F00DD | Word_422_enum_Bit12 | Unrecognized/Unentered Sensor Type (K1 Manditory) |
0x332F00DE | Word_422_enum_Bit13 | Core configuration database corrupt |
0x332F00DF | Word_422_enum_Bit14 | Core powerdown totals corrupt |
0x332F00E0 | Word_422_enum_Bit15 | Core program corrupt |
0x332F00E1 | Word_421_enum_Bit0 | Burst Mode Enabled |
0x332F00E2 | Word_421_enum_Bit1 | Power Reset Occurred |
0x332F00E3 | Word_421_enum_Bit2 | Transmitter Initializing/Warming Up (Low Power Fault) |
0x332F00E4 | Word_421_enum_Bit3 | Sensor/Xmtr Communication Failure (A28) |
0x332F00E5 | Word_421_enum_Bit4 | Paper Out |
0x332F00E6 | Word_421_enum_Bit5 | Event #2 Triggered |
0x332F00E7 | Word_421_enum_Bit6 | Event #1 Triggered |
0x332F00E8 | Word_421_enum_Bit7 | Sensor/Xmtr Communication Failure (A26) |
0x332F00E9 | Word_421_enum_Bit8 | Calibration Failure (Autozero,Density,Temperature) |
0x332F00EA | Word_421_enum_Bit9 | Excess Calibration Correction,Autozero too Low |
0x332F00EB | Word_421_enum_Bit10 | Excess Calibration Correction,Autozero too High |
0x332F00EC | Word_421_enum_Bit11 | Process too Noisy to Perform Auto Zero |
0x332F00ED | Word_421_enum_Bit12 | Transmitter Failed |
0x332F00EE | Word_421_enum_Bit13 | Data Loss Possible (Totals+Inventories Questionable) |
0x332F00EF | Word_421_enum_Bit14 | Calibration-In-Progress (Autozero, Density, Temperature) |
0x332F00F0 | Word_421_enum_Bit15 | Slug Flow |
0x332F00F1 | Word_424_enum_Bit0 | Discrete Input 1 Status |
0x332F00F2 | Word_424_enum_Bit1 | Discrete Input 2 Status |
0x332F00F3 | Word_424_enum_Bit2 | Discrete Output 1 Fixed |
0x332F00F4 | Word_424_enum_Bit3 | Discrete Output 2 Fixed |
0x332F00F5 | Word_424_enum_Bit4 | Discrete Output 3 Fixed |
0x332F00F6 | Word_424_enum_Bit5 | Discrete Output 4 Fixed |
0x332F00F7 | Word_424_enum_Bit6 | Security Breach |
0x332F00F8 | Word_424_enum_Bit7 | Frequency Input Saturated |
0x332F00F9 | Word_424_enum_Bit8 | Discrete Event 1 Status |
0x332F00FA | Word_424_enum_Bit9 | Discrete Event 2 Status |
0x332F00FB | Word_424_enum_Bit10 | Discrete Event 3 Status |
0x332F00FC | Word_424_enum_Bit11 | Discrete Event 4 Status |
0x332F00FD | Word_424_enum_Bit12 | Discrete Event 5 Status |
0x332F00FE | Word_424_enum_Bit13 | Undefined |
0x332F00FF | Word_424_enum_Bit14 | Undefined |
0x332F0100 | Word_424_enum_Bit15 | Incorrect Board Type (A30) |
0x332F0101 | Word_423_enum_Bit0 | Core Protected Boot Sector Fault |
0x332F0102 | Word_423_enum_Bit1 | Undefined |
0x332F0103 | Word_423_enum_Bit2 | Frequency Output Fixed |
0x332F0104 | Word_423_enum_Bit3 | Primary mA Readback Failure |
0x332F0105 | Word_423_enum_Bit4 | DO1 Status (0=OFF,1=ON) |
0x332F0106 | Word_423_enum_Bit5 | DO2 Status (0=OFF,1=ON) |
0x332F0107 | Word_423_enum_Bit6 | Dens T-Series D3 Calibration-in-Progress |
0x332F0108 | Word_423_enum_Bit7 | Dens T-Series D4 Calibration-in-Progress |
0x332F0109 | Word_423_enum_Bit8 | DO3 Status (0=OFF,1=ON) |
0x332F010A | Word_423_enum_Bit9 | DO4 Status (0=OFF,1=ON) |
0x332F010B | Word_423_enum_Bit10 | Temp Slope Calibration-in-Progress |
0x332F010C | Word_423_enum_Bit11 | Temp Zero Calibration-in-Progress |
0x332F010D | Word_423_enum_Bit12 | Dens FD Calibration-in-Progress |
0x332F010E | Word_423_enum_Bit13 | Dens D2 Calibration-in-Progress |
0x332F010F | Word_423_enum_Bit14 | Dens D1 Calibration-in-Progress |
0x332F0110 | Word_423_enum_Bit15 | Mechanical Zero Calibration-in-Progress |
0x332F0111 | Word_433_enum_Bit0 | K1/FCF Combination Unrecognized |
0x332F0112 | Word_433_enum_Bit1 | Warming Up |
0x332F0113 | Word_433_enum_Bit2 | Low Power |
0x332F0115 | Word_433_enum_Bit4 | Meter Verification/Outputs in fault (A32) |
0x332F0116 | Word_433_enum_Bit5 | Meter Verification/Outputs at last value (A131) |
0x332F0117 | Word_433_enum_Bit6 | Undefined |
0x332F0118 | Word_433_enum_Bit7 | Undefined |
0x332F0119 | Word_433_enum_Bit8 | Undefined |
0x332F011A | Word_433_enum_Bit9 | Undefined |
0x332F011B | Word_433_enum_Bit10 | Undefined |
0x332F011C | Word_433_enum_Bit11 | Undefined |
0x332F011D | Word_433_enum_Bit12 | Undefined |
0x332F011E | Word_433_enum_Bit13 | Undefined |
0x332F011F | Word_433_enum_Bit14 | Undefined |
0x332F0120 | Word_433_enum_Bit15 | Undefined |
0x332F0121 | Word_434_enum_Bit0 | Undefined |
0x332F0122 | Word_434_enum_Bit1 | Undefined |
0x332F0123 | Word_434_enum_Bit2 | Undefined |
0x332F0124 | Word_434_enum_Bit3 | Undefined |
0x332F0125 | Word_434_enum_Bit4 | Undefined |
0x332F0126 | Word_434_enum_Bit5 | Undefined |
0x332F0127 | Word_434_enum_Bit6 | Undefined |
0x332F0128 | Word_434_enum_Bit7 | Undefined |
0x332F0129 | Word_434_enum_Bit8 | Undefined |
0x332F012A | Word_434_enum_Bit9 | Undefined |
0x332F012B | Word_434_enum_Bit10 | Undefined |
0x332F012C | Word_434_enum_Bit11 | Undefined |
0x332F012D | Word_434_enum_Bit12 | Undefined |
0x332F012E | Word_434_enum_Bit13 | Undefined |
0x332F012F | Word_434_enum_Bit14 | Undefined |
0x332F0130 | Word_434_enum_Bit15 | Undefined |
0x332F0131 | Process_Variable_Code_enum_0 | Mass Flow Rate |
0x332F0132 | Process_Variable_Code_enum_1 | Temperature |
0x332F0133 | Process_Variable_Code_enum_2 | Mass Totalizer |
0x332F0134 | Process_Variable_Code_enum_3 | Density |
0x332F0135 | Process_Variable_Code_enum_4 | Mass Inventory Totalizer |
0x332F0136 | Process_Variable_Code_enum_5 | Line (Gross) Volume Flow Rate |
0x332F0137 | Process_Variable_Code_enum_6 | Line (Gross) Volume Totalizer |
0x332F0138 | Process_Variable_Code_enum_7 | Line (Gross) Volume Inventory Totalizer |
0x332F0139 | Process_Variable_Code_enum_46 | Raw Tube Frequency |
0x332F013A | Process_Variable_Code_enum_47 | Drive Gain |
0x332F013B | Process_Variable_Code_enum_48 | Meter Temperature (T-Series) |
0x332F013C | Process_Variable_Code_enum_49 | Left Pickoff Amplitude |
0x332F013D | Process_Variable_Code_enum_50 | Right Pickoff Amplitude |
0x332F013E | Process_Variable_Code_enum_51 | Board Temperature |
0x332F013F | Process_Variable_Code_enum_52 | Input Voltage |
0x332F0140 | Process_Variable_Code_enum_53 | External Pressure |
0x332F0141 | Process_Variable_Code_enum_55 | External Temperature |
0x332F0142 | Process_Variable_Code_enum_62 | Gas Standard Volume Flow |
0x332F0143 | Process_Variable_Code_enum_63 | Gas Standard Volume Total |
0x332F0144 | Process_Variable_Code_enum_64 | Gas Standard Volume Inventory |
0x332F0145 | Process_Variable_Code_enum_69 | Live Zero |
0x332F0146 | Process_Variable_Code_enum_251 | None |
0x332F0149 | Status_Change_enum_0 | inactive,acked |
0x332F014A | Status_Change_enum_1 | active,acked |
0x332F014B | Status_Change_enum_2 | inactive,unacked |
0x332F014C | Status_Change_enum_3 | active,unacked |
0x332F014D | mmi_alarm_code_enum_0 | A000: Undefined |
0x332F0154 | mmi_alarm_code_enum_7 | A007: Real-Time Interrupt Failure |
0x332F0156 | mmi_alarm_code_enum_9 | A009: Transmitter Initializing/Warming Up |
0x332F0157 | mmi_alarm_code_enum_10 | A010: Calibration Failure |
0x332F015C | mmi_alarm_code_enum_15 | A015: MA Readback Error |
0x332F015F | mmi_alarm_code_enum_18 | A018: (E) EPROM Checksum Error (Model 3000) |
0x332F0168 | mmi_alarm_code_enum_27 | A027: Security Breach |
0x332F016F | mmi_alarm_code_enum_34 | A034: Undefined |
0x332F0170 | mmi_alarm_code_enum_35 | A035: Undefined |
0x332F0171 | mmi_alarm_code_enum_36 | A036: Undefined |
0x332F0172 | mmi_alarm_code_enum_37 | A037: Undefined |
0x332F0173 | mmi_alarm_code_enum_38 | A038: Undefined |
0x332F0174 | mmi_alarm_code_enum_39 | A039: Undefined |
0x332F0178 | mmi_alarm_code_enum_43 | A103: Data Loss Possible |
0x332F0179 | mmi_alarm_code_enum_44 | A104: Calibration-In-Progress |
0x332F017A | mmi_alarm_code_enum_45 | A105: Slug Flow |
0x332F017B | mmi_alarm_code_enum_46 | A106: Burst Mode Enabled |
0x332F017C | mmi_alarm_code_enum_47 | A107: Power Reset Occurred |
0x332F018A | mmi_alarm_code_enum_61 | A121: ED: Extrapolation alarm |
0x332F018C | mmi_alarm_code_enum_63 | A123: Discrete Output 4 Fixed |
0x332F018D | mmi_alarm_code_enum_64 | A124: Frequency Input Saturated |
0x332F0199 | mmi_alarm_code_enum_76 | A136: Undefined |
0x332F019A | mmi_alarm_code_enum_77 | A137: Undefined |
0x332F019B | mmi_alarm_code_enum_78 | A138: Undefined |
0x332F019C | mmi_alarm_code_enum_79 | A139: Undefined |
0x332F019D | varMODBUS_Data_Type_Code_enum_0 | Reserved |
0x332F019E | varMODBUS_Data_Type_Code_enum_1 | Coil |
0x332F019F | varMODBUS_Data_Type_Code_enum_2 | Unsigned 16 |
0x332F01A0 | varMODBUS_Data_Type_Code_enum_3 | Unsigned 32 |
0x332F01A1 | varMODBUS_Data_Type_Code_enum_4 | Floating Point |
0x332F01A2 | Word_433_enum_Bit3_2400SA | Sensor OK / Tubes Stopped by Process (A33) |
0x332F01A3 | Word_420_enum_Bit5_2400SA | Drive Over-Range / Partially Full Tube |
0x332F01A7 | NTEP | NTEP |
0x332F01A8 | OIML | OIML |
0x332F01A9 | not_resetable | Not reset-able from display or digital communications |
0x332F01AA | reset_frm_display | Reset-able from display only |
0x332F01AB | reset_frm_comm | Reset-able from digital communications only |
0x332F01AC | reset_frm_disp_comm | Reset-able from display and digital communications |
0x332F01AD | mmi_disable_abort_verification | Disable or abort verification |
0x332F01AE | mmi_normal_verification | Normal verification |
0x332F01AF | mmi_factory_verification_air | Factory verification of Air |
0x332F01B0 | mmi_factory_verification_water | Factory verification of Water |
0x332F01B1 | mmi_last_value | Last value |
0x332F01B2 | mmi_fault | Fault |
0x332F01B3 | mmi_no_error | No error |
0x332F01B4 | mmi_manual_abort | Manual abort |
0x332F01B5 | mmi_watchdog_timeout | Watchdog Timeout |
0x332F01B6 | mmi_frequency_drift | Frequency Drift |
0x332F01B7 | mmi_high_peak_drive_voltage | High Peak Drive Voltage |
0x332F01B8 | mmi_high_peak_current_std_dev | High Drive Current Std Dev |
0x332F01B9 | mmi_high_peak_current_mean_value | High Drive Current Mean Value |
0x332F01BA | mmi_drive_loop_reported_error | Drive loop reported error |
0x332F01BB | mmi_high_DeltaT_std_dev | High Delta T Std Dev |
0x332F01BC | mmi_high_DeltaT_value | High Delta T Value |
0x332F01BD | mmi_state_running | State Running |
0x332F01BE | mmi_ResetAllEDCurveInfo | Reset All Enhanced Density Curve Information |
0x332F01BF | mmi_EnableWriteProtect | Enable write protect |
0x332F01C0 | mmi_DisableWriteProtect | Disable write protect |
0x332F01C5 | mmi_Restore_Factory_Zero | Restore Factory Zero |
0x332F01C7 | mmi_reset_api_vol_total | Reset API Reference (Std) Vol Totl |
0x332F01C8 | mmi_reset_mass_tot_only | Reset Mass Total Only |
0x332F01C9 | mmi_reset_ed_ref_vol_tot | Reset ED Ref. (Corrected) Vol Totl |
0x332F01CA | mmi_reset_ed_net_mass_tot | Reset ED Net Mass Totl |
0x332F01CB | mmi_reset_ed_net_vol_tot | Reset ED Net Volume Totl |
0x332F01CC | mmi_reset_api_ref_vol_inv_only | Reset API Ref. (Std) Vol Inv Only |
0x332F01CD | mmi_reset_line_vol_tot_only | Reset Line Vol. Totl Only |
0x332F01CE | mmi_reset_ed_ref_vol_inv_only | Reset ED Ref. (Corrected) Vol Inv Only |
0x332F01CF | mmi_reset_ed_net_mass_inv_only | Reset ED Net Mass Inv Only |
0x332F01D0 | mmi_reset_ed_net_vol_inv_only | Reset ED Net Vol Inv Only |
0x332F01D1 | mmi_reset_gas_std_vol_inv_only | Reset Gas Std Vol Inv Only |
0x332F01D2 | mmi_verification_complete | Verification complete |
0x332F01D3 | mmi_wrong_verification_enable | Wrong verification enable |
0x332F01D4 | mmi_no_factory_air_varification | No factory air verification |
0x332F01D5 | mmi_no_factory_water_varification | No factory water verification |
0x332F01D6 | mmi_param_registers_not_set | Parameter registers not set |
0x332F01ED | Status_Change_posted | Posted |
0x332F01EE | Status_Change_cleared | Cleared |
0x332F01EF | msec | msec |
0x332F01F1 | mmi_alarm_code_enum_1_b | A001: EEPROM Error (CP) |
0x332F01F2 | mmi_alarm_code_enum_2_b | A002: RAM Error (CP) |
0x332F01F3 | mmi_alarm_code_enum_3_b | A003: No Sensor Response |
0x332F01F4 | mmi_alarm_code_enum_4_b | A004: Temperature Overrange |
0x332F01F5 | mmi_alarm_code_enum_5_b | A005: Mass Flow Overrange |
0x332F01F6 | mmi_alarm_code_enum_6_b | A006: Characterization Required |
0x332F01F7 | mmi_alarm_code_enum_8_b | A008: Density Overrange |
0x332F01F8 | mmi_alarm_code_enum_11_b | A011: Zero Calibration Failed: Low |
0x332F01F9 | mmi_alarm_code_enum_12_b | A012: Zero Calibration Failed: High |
0x332F01FA | mmi_alarm_code_enum_13_b | A013: Zero Calibration Failed: Unstable |
0x332F01FB | mmi_alarm_code_enum_14_b | A014: Transmitter Failure |
0x332F01FC | mmi_alarm_code_enum_16_b | A016: Sensor RTD Failure |
0x332F01FD | mmi_alarm_code_enum_17_b | A017: T-Series RTD Failure |
0x332F01FF | mmi_alarm_code_enum_19_b | A019: RAM Error (Xmtr) |
0x332F0200 | mmi_alarm_code_enum_20_b | A020: No Flow Cal Value |
0x332F0201 | mmi_alarm_code_enum_21_b | A021: No K1 Value |
0x332F0202 | mmi_alarm_code_enum_22_b | A022: Config DB Corrupt (CP) |
0x332F0203 | mmi_alarm_code_enum_23_b | A023: Internal Totals Corrupt (CP) |
0x332F0204 | mmi_alarm_code_enum_24_b | A024: Program Corrupt (CP) |
0x332F0205 | mmi_alarm_code_enum_25_b | A025: Boot Sector Fault (CP) |
0x332F0206 | mmi_alarm_code_enum_26_b | A026: Sensor/Xmtr Comm Failure |
0x332F0207 | mmi_alarm_code_enum_28_b | A028: CP Write Failure |
0x332F0208 | mmi_alarm_code_enum_29_b | A029: PIC/Daughterboard Comm Failure |
0x332F0209 | mmi_alarm_code_enum_30_b | A030: Incorrect Board Type |
0x332F020A | mmi_alarm_code_enum_31_b | A031: Low Power |
0x332F020B | mmi_alarm_code_enum_32_b | A032: MV: Outputs to Fault |
0x332F020C | mmi_alarm_code_enum_33_b | A033: No LPO/RPO Signal |
0x332F020D | mmi_alarm_code_enum_40_b | A100: MAO1 Saturated |
0x332F020E | mmi_alarm_code_enum_41_b | A101: MAO1 Fixed |
0x332F020F | mmi_alarm_code_enum_42_b | A102: Drive Overrange |
0x332F0210 | mmi_alarm_code_enum_48_b | A108: Single-SP Event 1 ON |
0x332F0211 | mmi_alarm_code_enum_49_b | A109: Single-SP Event 2 ON |
0x332F0212 | mmi_alarm_code_enum_50_b | A110: FO Saturated |
0x332F0213 | mmi_alarm_code_enum_51_b | A111: FO Fixed |
0x332F0214 | mmi_alarm_code_enum_52_b | A112: Upgrade Transmitter Software |
0x332F0215 | mmi_alarm_code_enum_53_b | A113: MAO2 Saturated |
0x332F0216 | mmi_alarm_code_enum_54_b | A114: MAO2 Fixed |
0x332F0217 | mmi_alarm_code_enum_55_b | A115: No External Data |
0x332F0218 | mmi_alarm_code_enum_56_b | A116: API: Temperature Overrange |
0x332F0219 | mmi_alarm_code_enum_57_b | A117: API: Density Overrange |
0x332F021A | mmi_alarm_code_enum_58_b | A118: DO1 Fixed |
0x332F021B | mmi_alarm_code_enum_59_b | A119: DO2 Fixed |
0x332F021C | mmi_alarm_code_enum_60_b | A120: ED: Curve Fit Failure |
0x332F021D | mmi_alarm_code_enum_62_b | A122: DO3 Fixed |
0x332F021E | mmi_alarm_code_enum_64_b | A124: FI Saturated |
0x332F021F | mmi_alarm_code_enum_65_b | A125: Batch Timeout |
0x332F0220 | mmi_alarm_code_enum_66_b | A126: Batch Overrun |
0x332F0221 | mmi_alarm_code_enum_67_b | A127: Batch No Reset |
0x332F0222 | mmi_alarm_code_enum_68_b | A128: Batch/Fill No Start |
0x332F0223 | mmi_alarm_code_enum_69_b | A129: PPI Display Error |
0x332F0224 | mmi_alarm_code_enum_70_b | A130: Printer Out of Paper |
0x332F0225 | mmi_alarm_code_enum_71_b | A131: MV: Outputs to LMV |
0x332F0226 | mmi_alarm_code_enum_72_b | A132: Sensor Simulation Active |
0x332F0227 | mmi_alarm_code_enum_73_b | A133: PIC UI EEPROM Error |
0x332F0228 | mmi_alarm_code_enum_74_b | A134: PPI Memory Error |
0x332F0229 | mmi_alarm_code_enum_75_b | A135: PPI Communication Error |
0x33300000 | mmi_dens_temp_grad_oor_label | Density Temp. Gradient out-of-range |
0x33300001 | mmi_dens_freq_const1_oor_label | Density Frequency Constant 1 out-of-range |
0x33300002 | mmi_dens_freq_const2_oor_label | Density Frequency Constant 2 out-of-range |
0x33300003 | mmi_flow_temp_const_oor_label | Flow Temperature Constant out-of-range |
0x33300004 | mmi_flow_freq_const_oor_label | Flow Frequency Constant out-of-range |
0x33300005 | mmi_invalid_cutoff_type_code_label | Invalid Cutoff Type Code |
0x33300008 | mmi_invalid_output_number_code | Invalid Output Code |
0x33300009 | mmi_zero_pres_corr_resp_label | Zero Pres. Correction Pt. too low |
0x33300010 | mmi_invalid_sensor_type_code_label | Invalid sensor type code |
0x33300015 | mmi_spcl_mass_conv_oor | Special units mass conversion number out of range |
0x33300016 | mmi_frequency_oor | Frequency out of range |
0x33300017 | mmi_flow_rate_factor_oor | Flow rate factor out of range |
0x33300018 | mmi_pulses_per_unit_oor | Pulses/Unit out of range |
0x33300019 | mmi_units_per_pulse_oor | Units/Pulse out of range |
0x3330001A | mmi_spcl_vol_conv_oor | Special units volume conversion number out of range |
0x3330001B | mmi_density_high_limit_oor | Density high limit out of range |
0x3330001C | mmi_density_low_limit_oor | Density low limit out of range |
0x3330001D | mmi_slug_duration_oor | Slug duration out of range |
0x3330001E | mmi_maximum_zeroing_time_oor | Maximum zeroing time out of range |
0x3330001F | mmi_maximum_pulse_width_oor | Maximum pulse width out of range |
0x33300020 | mmi_analog_fault_level_oor | Analog fault level out of range |
0x33300021 | mmi_fault_timeout_oor | Fault timeout out of range |
0x33300022 | mmi_dens_for_cal_oor | Density for calibration out of range |
0x33300023 | mmi_fdcalval_oor | FD correction factor out of range |
0x33300024 | mmi_d3_oor | D3 out of range |
0x33300025 | mmi_d4_oor | D4 out of range |
0x33300026 | mmi_k3_oor | K3 out of range |
0x33300027 | mmi_k4_oor | K4 out of range |
0x33300028 | mmi_low_cutoff_oor | Low flow cutoff out of range |
0x33300029 | mmi_d1_oor | D1 out of range |
0x3330002A | mmi_d2_oor | D2 out of range |
0x3330002B | mmi_k1_oor | K1 out of range |
0x3330002C | mmi_k2_oor | K2 out of range |
0x3330002D | mmi_temp_comp_oor | Temp correction factor out of range |
0x3330002E | mmi_sp_oor | Setpoint out of range |
0x3330002F | mmi_mass_fact_oor | Mass rate flow factor out of range |
0x33300030 | mmi_dens_fact_oor | Density factor out of range |
0x33300031 | mmi_vol_fact_oor | Volume rate flow factor out of range |
0x33300032 | mmi_do_indx_oor | DO index out-of-range |
0x33300037 | mmi_dens_pres_corr_resp_label | Density pressure correction value out-of-range |
0x33300038 | mmi_flow_pres_corr_resp_label | Flow pressure correction value out-of-range |
0x33300039 | mmi_flow_switch_oor | Flow switch setpoint value out-of-range |
0x3330003A | mmi_invalid_ctl_table | Invalid CTL Table Type |
0x3330003B | mmi_therm_exp_coeff_oor | Thermal Expansion Coefficient out of range |
0x3330003C | mmi_ref_temp_oor | Reference Temperature out of range |
0x3330003D | mmi_invalid_api_units | Invalid units |
0x3330003F | mmi_fo_disabled_oor | FO Disabled |
0x33300040 | mmi_di_indx_oor | DI index out-of-range |
0x33300041 | mmi_di_assign_oor | DI assignment out-of-range |
0x33300042 | mmi_di_disabled_oor | DI Disabled |
0x33300043 | mmi_do_disabled | DO Disabled |
0x33300044 | mmi_do_state_oor | DO state out-of-range |
0x33300049 | mmi_polarity_oor | Invalid Polarity |
0x3330004A | mmi_density_cutoff_oor | Density cutoff out of range |
0x3330004B | mmi_density_units_oor | Invalid density cutoff units |
0x3330004C | mmi_invalid_option_label | Invalid Option |
0x3330004D | mmi_static_pres_resp_label | Static Pressure value out-of-range |
0x3330004E | mmi_static_temp_resp_label | Static Temperature value out-of-range |
0x33300050 | mmi_di_polarity_oor | DI polarity out-of-range |
0x33300051 | mmi_do_polarity_oor | DO polarity out-of-range |
0x33300056 | mmi_pc_indx_oor | Discrete Event Index out-of-range |
0x33300057 | mmi_pc_pv_code_oor | Discrete Event PV Code out-of-range |
0x33300058 | mmi_pc_action_oor | Discrete Event Action out-of-range |
0x33300059 | mmi_pc_setpointA_oor | Discrete Event Setpoint A out-of-range |
0x3330005A | mmi_pc_setpointB_oor | Discrete Event Setpoint B out-of-range |
0x3330006A | mmi_alarm_integer_oor | Alarm Number invalid |
0x3330006B | mmi_alarm_severity_oor | Alarm Severity invalid |
0x3330006C | mmi_di_action_oor | DI action invalid |
0x33300071 | mmi_FaultIndicationInvalid | Fault Indication Invalid |
0x33300072 | mmi_CoilorStartingRegisterOutofRange | Coil or Starting Register Out of Range |
0x33300073 | mmi_IllegalCoilValue | Value Out of Range |
0x33300077 | mmi_GasDensityOutofRange | Gas Density Out of Range |
0x33300078 | mmi_GSVFlowUnitOutofRange | GSV Flow Unit Out of Range |
0x33300079 | mmi_GSVTotalunitOutofRange | GSV Total unit Out of Range |
0x3330007A | mmi_BaseVolumeFlowUnitsCodeOutofRange | Base Volume Flow Units Code Out of Range |
0x3330007B | mmi_BaseVolumeTimeUnitsCodeOutofRange | Base Volume Time Units Code Out of Range |
0x3330007C | mmi_SpecialUnitsConversionFactoryOutofRange | Special Units Conversion Factory Out of Range |
0x3330007D | mmi_SimulationModeoutofrange | Simulation Mode out of range |
0x3330007E | mmi_FixedValueOutofRange | Fixed Value Out of Range |
0x3330007F | mmi_MinimumAmplitudeOutofRange | Minimum Amplitude Out of Range |
0x33300080 | mmi_MaximumAmplitudeOutofRange | Maximum Amplitude Out of Range |
0x33300081 | mmi_PeriodOutofRange | Period Out of Range |
0x33300087 | mmi_invalid_custrf_option | Invalid Custody Transfer Totalizer Option |
0x33310027 | mmi_batching | Batching |
0x33310028 | mmi_batch_end_warning | Batch End Warning |
0x33310029 | mmi_batch_overrun | Batch Overrun |
0x3331002A | mmi_batch_pump | Batch Pump On |
0x3331002B | mmi_batch_primary_valve | Batch Primary Valve On |
0x3331002C | mmi_batch_secondary_valve | Batch Secondary Valve On |
0x3331002F | mmi_cal_in_progress | Cal in progress |
0x3331009D | mmi_PPI_Error | PPI Readback Error |
0x33320001 | mmi_alarm_select_help_index | Determines whether the Event is activated when it goes above (High) or below (Low) the setpoint. |
0x33320002 | mmi_hzfreq_help_index | The number of cycles,in Hertz,that equal a proportional flow rate represented by the frequency/pulse output. |
0x33320003 | mmi_hzrate_help_index | The flow rate that equals a set frequency if the frequency output represents mass or volume flow ; or the mass or volume total that equals a set number of pulses if the frequency output represents mass or volume total. |
0x33320004 | mmi_vol_flow_digital_cutoff_help_index | The volume flow rate below which the frequency/pulse output indicates zero flow,and below which totalizers stop counting. |
0x33320005 | mmi_flange_type_help_index | Configuration information identifying the flange material used with the sensor. Informational purposes only - does not affect flowmeter operation. |
0x33320006 | mmi_liner_matl_help_index | Configuration information identifying any liner material used with the sensor. Informational purposes only - does not affect flowmeter operation. |
0x33320007 | mmi_sensor_model_help_index | Configuration information identifying the sensor model installed. Informational purposes only - does not affect flowmeter operation. |
0x33320008 | mmi_sensor_matl_help_index | Configuration information identifying the material of which the sensor is constructed. Informational purposes only - does not affect flowmeter operation. |
0x33320009 | mmi_sp_mass_help_index | A standard engineering unit that serves as the mass component in a special unit. |
0x3332000A | mmi_sp_mass_time_help_index | A standard unit of time (seconds,minutes,hours,or days) that serves as the time component in a special unit. |
0x3332000C | mmi_sp_mass_rate_text_help_index | A 1 to 8 character description of a special unit of flow. |
0x3332000D | mmi_sp_mass_total_text_help_index | A 1 to 8 character description of a special unit of mass,which is based on the special unit of flow to represent total. |
0x3332000E | mmi_slughi_help_index | A programmable high limit on density,which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. |
0x3332000F | mmi_sluglo_help_index | A programmable low limit on density,which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. |
0x33320010 | mmi_flocal_help_index | A 10-character factor that describes the sensitivity of the sensor to mass flow. The first 6 characters are the flow rate, in grams/second, per microsecond of time shift between velocity signals from the sensor. The 2nd four characters are the flow temperature coefficient. |
0x33320011 | mmi_ma_cutoff_help_index | The mass or volume flow rate below which a milliamp output representing flow indicates zero flow. |
0x33320012 | mmi_sp_volume_help_index | A standard engineering unit that serves as the volume component in a special unit. |
0x33320013 | mmi_sp_volume_time_help_index | A standard unit of time (seconds,minutes,hours,or days) that serves as the time component in a special unit. |
0x33320015 | mmi_sp_volume_rate_text_help_index | A 1 to 8 character description of a special unit of flow. |
0x33320016 | mmi_sp_volume_total_text_help_index | A 1 to 8 character description of a special unit of volume,which is based on the special unit of flow to represent total. |
0x33320017 | mmi_fixfreq_help_index | A value (in Hertz) that will be indicated on the frequency output for the purpose of a loop test. |
0x33320019 | mmi_pulse_width_help_index | A programmable time period,in seconds,that defines the crossover frequency for the frequency output,where Crossover freq. = 1 / (2 x Pulse width) . Below the crossover,the output has a constant ON state,and an OFF state that varies with frequency. |
0x3332001A | mmi_tempcal_help_index | A 14-character factor that describes the slope and offset of the linear output representing flow tube temperature. |
0x3332001B | mmi_rt_zero_help_index | A value,in microseconds,representing the phase shift between velocity signals from the sensor when measuring zero flow. |
0x3332001C | mmi_rt_sigma_help_index | A unitless value which characterizes the amount of deviation between readings during an Auto Zero operation. |
0x3332001D | mmi_timeout_help_index | A programmable time period,from 0.00 to 60.00 seconds,during which outputs representing flow hold their last measured value before indicating slug flow. |
0x33320020 | mmi_D1_help_index | The density,in g/cc,of the air or other low-density fluid used during a 2-point density calibration. |
0x33320021 | mmi_D2_help_index | The density,in g/cc,of the water or other high-density fluid used during a 2-point density calibration. |
0x33320022 | mmi_K1_help_index | The tube period,in microseconds,corresponding to a density equal to D1. |
0x33320023 | mmi_K2_help_index | The tube period,in microseconds,corresponding to a density equal to D2. |
0x33320024 | mmi_DCoef_help_index | The percent change in the elasticity of the flow tubes around the bending axis per 100 degrees Celsius. |
0x33320025 | mmi_alarm_type_help_index | Determines whether the Event is activated when it goes above (High) or below (Low) the setpoint. |
0x33320026 | mmi_rt_freq_help_index | The frequency,in Hertz,presently being indicated on the frequency output. |
0x33320028 | mmi_date_help | Date- Gregorian calendar date,entered as mm/dd/yy,that is stored in the Field Device. This date can be used by the user in any way. There is no specific recommended use. |
0x33320029 | mmi_temp_for_cal_help_index | User-entered temperature for the purpose of performing an on-line temperature calibration. |
0x3332002A | mmi_auto_zero_help_index | Please refer to manual for complete calibration instructions. |
0x3332002B | mmi_density_cal_help_index | Please refer to manual for complete calibration instructions. |
0x3332002C | mmi_fix_frequency_output_help_index | Outputs a user-programmed frequency to the frequency output. |
0x3332002D | mmi_self_test_help_index | Instructs transmitter to perform internal self test. |
0x3332002E | mmi_totctl_help_index | Allows the user to Reset,Stop,or Start all totalizers. NOTE - Inventory totals are NOT reset. |
0x3332002F | mmi_abort_auto_zero_help_index | Aborts Auto Zero operation and continues to use previous zero offset value. |
0x33320030 | mmi_leave_fixed_freq_mode_help_index | Exits fixed mode and returns the frequency output to its active state. |
0x33320031 | mmi_Event_1_Status_help_index | When set,indicates that Event 1 has reached its programmed setpoint. |
0x33320032 | mmi_Event_2_Status_help_index | When set,indicates that Event 2 has reached its programmed setpoint. |
0x33320033 | mmi_report_xmtr_status_help_index | Reports any currently active device status information. |
0x33320034 | mmi_total_start_help_index | Enables the internal totalizers to begin counting. |
0x33320035 | mmi_total_stop_help_index | Prevents the internal totalizers from counting. |
0x33320036 | mmi_total_reset_help_index | Resets internal totalizers. |
0x33320037 | mmi_temp_calibration_help_index | Please refer to manual for complete calibration instructions. |
0x33320038 | mmi_tube_freq_help_index | The tube frequency of the sensor measured in Hertz. |
0x33320039 | mmi_tube_amplitude_help_index | The pickoff voltage of the sensor measured in Voltage. |
0x3332003A | mmi_drive_gain_help_index | The drive gain of the transmitter. |
0x3332003B | mmi_live_zero_help_index | This flow value is not effected by the flow cutoff and is damped at 8 seconds. It is to be used for diagnostic purposes only and is not used in ANY flow calculations or totalization. |
0x3332003D | mmi_fd_help_index | A calibration constant generated during a flowing density calibration. |
0x3332003E | mmi_pulses_unit_help_index | This parameter allows you to scale the frequency output in terms of the number of pulses per unit of flow. |
0x3332003F | mmi_units_pulse_help_index | This parameter allows you to scale the frequency output in terms of the number of units of flow required to generate one pulse. |
0x33320041 | mmi_fo_scaling_help_index | This parameter allows you to scale the frequency output by using freq=flow,pulses/unit,or units/pulse. This parameter must be sent to the device before you make scaling changes. |
0x33320042 | mmi_dens_tgco_help_index | This parameter represents the Density Temperature Gradient Coefficient (DTG) that is on the T-series sensor tag. |
0x33320043 | mmi_dens_fqco1_help_index | This parameter represents the Density Frequency Coefficient #1 (DFQ1) that is on the T-series sensor tag. |
0x33320044 | mmi_dens_fqco2_help_index | This parameter represents the Density Frequency Coefficient #2 (DFQ2) that is on the T-series sensor tag. |
0x33320045 | mmi_flow_tgco_help_index | This parameter represents the Flow Temperature Gradient Coefficient (FTG) that is on the T-series sensor tag. |
0x33320046 | mmi_flow_fqco_help_index | This parameter represents the Flow Frequency Coefficient (FFQ) that is on the T-series sensor tag. |
0x33320047 | mmi_ma_fault_level_help_index | This parameter allows you to select the lower or upper mA output level that will indicate a fault condition. The range is 1.0 to 3.6 mA for downscale or 21.0 to 24.0 for upscale. |
0x33320049 | mmi_ldo_tot_reset_help_index | When this parameter is enabled,you can use the display to reset the totalizer. |
0x3332004A | mmi_ldo_auto_scroll_help_index | When this parameter is enabled,you do not need to press the scroll button to scroll through the configured process variables. |
0x3332004B | mmi_ldo_offline_menu_help_index | When this parameter is enabled,you can use the display to access the offline maintenance menu. |
0x3332004C | mmi_ldo_alarm_menu_help_index | When this parameter is enabled,you can use the display to acknowledge and view the specific alarm conditions that are present. When this parameter is disabled,all alarms will be automatically acknowledged without user intervention. |
0x3332004D | mmi_ldo_ack_all_help_index | When this parameter is enabled,an option in the alarm menu allows you to acknowledge all of the alarms at once. |
0x3332004E | mmi_ldo_offline_password_help_index | When this parameter is enabled you must enter a password to gain access to the offline menu. |
0x3332004F | mmi_ldo_password_help_index | This parameter defines the password that you must enter to gain access to the offline menu. The valid range is 0 to 9999. |
0x33320050 | mmi_pv_disp_help_index | This parameter allows you to select the process variables that will appear on the display. Up to 15 process variables can be configured to appear on the display. They can be accessed by using the scroll button. |
0x33320051 | mmi_rs485_protocol_help_index | This parameter defines the protocol that will be used on the RS485 physical layer. |
0x33320052 | mmi_rs485_baudrate_help_index | This parameter defines the baud rate for the protocol that will be used on the RS485 physical layer. |
0x33320053 | mmi_rs485_parity_help_index | This parameter defines the parity for the protocol that will be used on the RS485 physical layer. |
0x33320054 | mmi_rs485_stop_help_index | This parameter defines the number of stop bits for the protocol that will be used on the RS485 physical layer. |
0x33320057 | mmi_fault_code_help_index | Downscale: Milliamp outputs that indicate flow go to the configured limit,the frequency output equals 0 Hz. Upscale: Milliamp and frequency outputs go to the configured limit. Internal zero: Flow outputs indicate zero flow. |
0x33320058 | mmi_mass_rate_factor_help_index | A value,between 0.8 and 1.2,that will act as a multiplier for the mass flow rate. |
0x33320059 | mmi_vol_rate_factor_help_index | A value,between 0.8 and 1.2,that will act as a multiplier for the volume flow rate. |
0x3332005A | mmi_dens_factor_help_index | A value,between 0.8 and 1.2,that will act as a multiplier for the density. |
0x3332005B | mmi_fo_fault_level_help_index | This parameter allows you to select the upper frequency output level that will indicate a fault condition. The maximum value is 15000 Hz. |
0x3332005E | mmi_dig_fault_code_help_index | This fault setting applies to Modbus on RS485 and the display. Downscale: Hold process variables at values that are less than the Lower Sensor Limits and stop totalizing. Upscale: Hold process variables at values that are greater than the Upper Sensor Limits and stop totalizing. Not-a-Number: Set all process variables to IEEE NaN. IntZero-All 0: Set all process variables to 0. IntZero-Flow 0: Set flow rate to 0. None: Process variables displayed as measured (NOTE: Use alternative method to detect fault conditions when NONE is selected) |
0x3332005F | mmi_d3_help_index | The density,in g/cc,of the water or other high-density fluid that is used during a 4-point density calibration with Micro Motion T-series sensors. D3 can represent the D3 value for a Micro Motion T-series sensor. |
0x33320060 | mmi_d4_help_index | The density,in g/cc,of the water or other high-density fluid that is used during a 4-point density calibration with Micro Motion T-series sensors. D4 can represent the D4 value for a Micro Motion T-series sensor. |
0x33320061 | mmi_K3_help_index | The tube period,in microseconds,corresponding to a density equal to D3. |
0x33320062 | mmi_K4_help_index | The tube period,in microseconds,corresponding to a density equal to D4. |
0x33320063 | mmi_poll_ctrl_help_index | A variable that represents how process variables are brought into the transmitter for the purpose of performing a pressure compensation or other calculations. |
0x33320065 | mmi_output_opt_brd_help | This parameter represents the various types of output option boards that are available. |
0x33320066 | mmi_sens_setup_meth_help | This selection must be made to enable calibration parameters to be visible for the selected sensor type. |
0x33320067 | mmi_alarm_setpoint_help_index | A programmable value of a process variable at which an output set to represent event 1 or event 2 switches states. |
0x33320068 | mmi_alarm_varcode_help_index | Assigns a process variable to event 1 or event 2. |
0x33320069 | mmi_board_temp_help_index | The board temperature of the core processor. |
0x3332006A | mmi_case_temp_help_index | The meter temperature of the T-Series sensor. |
0x3332006C | mmi_lmv_fault_timeout_help | This parameter defines the number of seconds for which all outputs will hold their last measured value prior to going to the configured fault state. The default is zero seconds. |
0x3332006D | mmi_digital_units_help | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation,Minimum Span,Upper Range Value,Lower Range Value,Lower Sensor Limit,and Upper Sensor Limit. |
0x3332006E | mmi_dp_tag_help_index | This represents the tagname for the device(s) being polled for a processvariable used internally for some compensation (e.g. pressure comp). |
0x3332006F | mmi_poll_var_help_index | This represents the variable code which will be read via HART for the compensation. |
0x33320070 | mmi_poll_type_help_index | This parameter identifies which compensation algorithms will be enabled within the device based on the polling being done. |
0x33320072 | mmi_do_assign_help_index | This parameter identifies which condition the discrete output will act upon. |
0x33320075 | mmi_flow_pres_factor_help_index | Pressure compensation factor applied to flow rate (% change per PSI) . |
0x33320076 | mmi_dens_pres_factor_help_index | Pressure compensation factor applied to density (g/Cucm change per PSI) . |
0x33320077 | mmi_zero_pres_factor_help_index | Pressure at which flow calibration was performed. |
0x33320078 | mmi_flow_switch_setpoint_help_index | This parameter can be used to trigger a discrete output when the mass flow rate exceeds the configured setpoint. There is a fixed hysteresis of 5% for this setpoint. |
0x3332007B | mmi_dx_state_help_index | This parameter identifies the state of the discrete output. |
0x3332007C | mmi_api_ctl_table_type_help_index | This parameter allows you to select the 2540 CTL Table Type for API. |
0x3332007D | mmi_api_thermal_exp_coeff_help_index | This parameter allows you to select the Thermal Expansion Coefficient API. The units are the inverse of the temperature user units. |
0x3332007E | mmi_api_ref_temp_help_index | This parameter allows you to select the Reference Termperature for API. The units must be the same as the temperature user units. |
0x3332007F | mmi_api_ctl_help_index | This parameter displays the Correction of Temperature on a Liquid. |
0x33320081 | mmi_di_assign_help_index | This parameter identifies the action the discrete input will initiate. |
0x33320083 | mmi_chan_power_help_index | This parameter identifies the power source (Internal or External) for the output channel. |
0x33320084 | mmi_fix_discrete_output_help_index | Outputs a user-programmed discrete state to the discrete output. |
0x33320085 | mmi_leave_fixed_do_mode_help_index | Exits fixed mode and returns the discrete output to its active state. |
0x3332008A | mmi_dens_digital_cutoff_help_index | The density below which the density indicates zero. |
0x3332008B | mmi_fo_polarity_help_index | This parameter allows you to set the polarity of the frequency output. |
0x3332008C | mmi_enable_pres_comp_help_index | This parameter allows you to enable/disable the pressure correction feature |
0x3332008D | mmi_static_pressure_help_index | This parameter allows you to enter a static pressure when using the pressure correction feature |
0x3332008E | mmi_enable_api_help_index | This parameter allows you to enable/disable the api feature |
0x3332008F | mmi_enable_extern_temp_help_index | This parameter allows you to enable/disable the external temperature feature |
0x33320090 | mmi_static_temperature_help_index | This parameter allows you to enter a static temperature when using the external temperature feature |
0x33320091 | mmi_di_state_help_index | This parameter identifies the state of the discrete input. |
0x33320092 | mmi_api_setup_help | This method will step the user through setting up the API parameters. |
0x33320093 | mmi_fo_power_help_index | This parameter identifies the power source (Internal or External) for the frequency output. |
0x33320094 | mmi_di_polarity_help_index | This parameter allows you to set the polarity of the discrete input. |
0x3332009B | mmi_do_polarity_help_index | This parameter allows you to set the polarity of the discrete output. |
0x3332009C | mmi_pc_setpointA_help_index | The first programmable value of a process variable in which the Discrete Events compares with. |
0x3332009D | mmi_pc_setpointB_help_index | The second programmable value of a process variable in which the Discrete Events compares with. |
0x3332009E | mmi_pc_varcode_help_index | Assigns a process variable to the Discrete Events. |
0x3332009F | mmi_pc_type_help_index | Determines the type of comparison the Discrete Events is going to perform. |
0x333200B6 | mmi_discrete_action_code_help_index | Selects an action to be assigned to a discrete. |
0x333200B7 | mmi_discrete_assignment_help_index | Assigns a discrete to an action. Select none for no discrete assignment. |
0x333200B8 | mmi_alarm_integer_help | This parameter is the number of the alarm. For example,26 for alarm A26 and 42 for alarm A102. |
0x333200B9 | mmi_alarm_severity_help_index | Assigns a severity level to the currently selected alarm. |
0x333200BC | mmi_write_alarm_severity_help_index | Allows the user to change the severity level of an alarm. The alarms are represented by their alarm number. For example,A26 is 26 and A102 is 102. |
0x333200BF | mmi_read_discrete_assign_help_index | For a selected discrete action,reports the associated discrete assignment. |
0x333200C0 | mmi_review_discrete_assign_help_index | Cycles through the discrete actions and reports the associated discrete assignments. |
0x333200C1 | mmi_modbus_address_help_index | This parameter defines the Modbus slave address. Addresses 1-15,32-47,64-79,or 96-110 are allowed |
0x333200C3 | mmi_log_code_help_index | The type of log to be reset. |
0x333200C6 | mmi_current_ed_curve_help_index | The Enhanced Density Curve that is currently selected. |
0x333200D2 | tot_startstop_enable_help | Enable or disable the ability to start and stop the totalizers from the local display. |
0x333200D3 | Update_Period_help | The period in which the process variables on the local display are updated. (in msec) |
0x333200D4 | Backlight_Control_help | The state of the backlight on the local display. |
0x333200D5 | Backlight_Intensity_help | The amount of intensity of the backlight on the local display. Range is 0 to 63 where 0 is off and 63 is full on. |
0x333200D6 | modbus_Mode_help | The mode of the Modbus protocol |
0x333200D7 | varEnable_Simulation_Mode_help | The state of the overall simulation mode |
0x333200D8 | varMass_Flow_Simulation_Mode_help | The type of Mass Flow Simulation |
0x333200D9 | varMass_Flow_Minimum_Amplitude_of_waveform_HELP | Mass Flow Minimum Amplitude of waveform |
0x333200DA | varMass_Flow_Fixed_Value_HELP | Mass Flow Fixed Value |
0x333200DB | Status_Change_HELP | The change in the status |
0x333200DC | varMass_Flow_Maximum_Amplitude_of_waveform_HELP | Mass Flow Maximum Amplitude of waveform |
0x333200DD | varMass_Flow_period_of_waveform_HELP | Mass Flow period of waveform |
0x333200DE | varTemperature__Simulation_Mode_HELP | The type of Temperature Simulation |
0x333200DF | varTemperature_Fixed_Value_HELP | Temperature Fixed Value |
0x333200E0 | varTemperature_Minimum_Amplitude_of_waveform_HELP | Temperature Minimum Amplitude of waveform |
0x333200E1 | varTemperature_Maximum_Amplitude_of_waveform_HELP | Temperature Maximum Amplitude of waveform |
0x333200E2 | varTemperature_period_of_waveform_HELP | Temperature period of waveform |
0x333200E3 | vDensity__Simulation_Mode_HELP | The type of Density Simulation |
0x333200E4 | vDensity_Fixed_Value_HELP | Density Fixed Value |
0x333200E5 | vDensity_Minimum_Amplitude_of_waveform_HELP | Density Minimum Amplitude of waveform |
0x333200E6 | vDensity_Maximum_Amplitude_of_waveform_HELP | Density Maximum Amplitude of waveform |
0x333200E8 | mmi_2400A_chan_assign_help_index | This parameter identifies the physical output channel to be configured. Channel 1 is terminals 1 & 2 and Channel 2 is terminals 3 & 4 |
0x333200E9 | target_amplitude_help_index | Displays current target amplitude value. |
0x333200EE | mmi_timestamp_help_index | Time is measured in terms of time elapsed since trasmitter has been switched on first time. |
0x333200F2 | mmi_world_area_weight_help_index | Displays World Area for Weights and Measures Security |
0x333200F3 | mmi_cust_trans_tot_reset_help_index | Custody transfer totalizer reset options |
0x333200F5 | enable_meter_verification_help | Specifies meter verification enabling option |
0x333200F6 | output_state_meter_verification_help | Specifies Ouput state during meter verification |
0x333200F7 | mmi_validation_counter_help | Indicates the number of times the Meter Verification routine has successfully completed. |
0x333200F8 | mmi_LPO_stiffness_out_of_limits_help | Indicates whether LPO stiffness out of limits. |
0x333200F9 | mmi_RPO_stiffness_out_of_limits_help | Indicates whether RPO stiffness out of limits. |
0x333200FA | mmi_current_LPO_stiffness_mean_help | Current LPO stiffness mean value |
0x333200FB | mmi_current_RPO_stiffness_mean_help | Current RPO stiffness mean value |
0x333200FC | mmi_algorithm_progress_help | Algorithm progress -- in percentage completion |
0x333200FD | stiffness_limit_set_point_help | Stiffness limit set point for meter verification |
0x333200FF | mmi_current_damping_mean_help | Current damping mean value |
0x33320100 | mmi_current_LPO_mass_mean_help | Current LPO mass mean value |
0x33320101 | mmi_current_RPO_mass_mean_help | Current RPO mass mean value |
0x33320102 | mmi_current_LPO_stiffness_std_dev_help | Current LPO stiffness Standard Deviation value |
0x33320103 | mmi_current_RPO_stiffness_std_dev_help | Current RPO stiffness standard deviation value |
0x33320104 | mmi_current_damping_std_dev_help | Current damping standard deviation value |
0x33320105 | mmi_current_LPO_mass_std_dev_help | Current LPO mass standard deviation value |
0x33320106 | mmi_current_RPO_mass_std_dev_help | Current RPO mass standard deviation value |
0x33320107 | mmi_LPO_stiffness_fact_cali_air_mean_help | LPO stiffness mean value for factory calibration of air |
0x33320108 | mmi_RPO_stiffness_fact_cali_air_mean_help | RPO stiffness mean value for factory calibration of air |
0x33320109 | mmi_damping_fact_cali_air_mean_help | Damping mean value for factory calibration of air |
0x3332010A | mmi_LPO_mass_fact_cali_air_mean_help | LPO mass mean value for factory calibration of air |
0x3332010B | mmi_RPO_mass_fact_cali_air_mean_help | RPO mass mean value for factory calibration of air |
0x3332010C | mmi_LPO_stiffness_fact_cali_water_mean_help | LPO stiffness mean value for factory calibration of water |
0x3332010D | mmi_RPO_stiffness_fact_cali_water_mean_help | RPO stiffness mean value for factory calibration of water |
0x3332010E | mmi_damping_fact_cali_water_mean_help | Damping mean value for factory calibration of water |
0x3332010F | mmi_LPO_mass_fact_cali_water_mean_help | LPO mass mean value for factory calibration of water |
0x33320110 | mmi_RPO_mass_fact_cali_water_mean_help | RPO mass mean value for factory calibration of water |
0x33320111 | vDensity_period_of_waveform_HELP | Density period of waveform |
0x33320112 | mmi_process_variable_precision_help | The process variable of which display precision can be set |
0x33320113 | mmi_process_variable_precision_value_help | Number of decimal points to be displayed for the value |
0x33320114 | ETO_Number_help | Engineered to Order (ETO) number for the transmitter |
0x33320119 | mmi_meter_verification_help | Starts meter verification and shows the result PASS or FAIL. This procedure takes upto 4 minutes. |
0x3332011A | mmi_reset_api_ref_vol_total_help | Resets internal totalizers for API Reference (Standard) Volume Total |
0x3332011B | mmi_reset_ed_ref_corr_vol_total_help | Resets internal totalizers for ED Reference (Corrected) Volume Total. |
0x3332011C | mmi_reset_ed_net_mass_total_help | Resets internal totalizers ED Net Mass Total. |
0x3332011D | reset_ed_net_vol_total_help | Resets internal totalizers for ED Net Volume Total. |
0x3332011E | reset_ED_gas_std_vol_total_help | Resets internal totalizers for Gas Standard Volume Total. |
0x3332011F | mmi_sp_mass_fact_help_index_ver5 | A programmable divider for the base mass unit in a special unit. |
0x33320120 | mmi_sp_volume_fact_help_index_ver5 | A programmable divider for the base volume unit in a special unit. |
0x33320121 | mmi_max_zero_help_index_ver5 | The amount of time the transmitter takes to determine its zero-flow reference point. The default zero time is 20 seconds. |
0x33320122 | mmi_met_direct_help_index_ver5 | This parameter enables the user to determine whether the outputs and totalizers will indicate forward,reverse,bi-directional or absolute value flow. |
0x33320123 | mmi_sens_type_code_help_ver5 | This parameter indicates which type of sensor is being used for process measurement. |
0x33320124 | mmi_ldo_scroll_rate_help_ver5 | This parameter allows you to set the rate at which the display will scroll from one process variable to the next. Display Auto Scroll must be enabled. |
0x33320125 | mmi_dp_tag_help_index_ver5 | This represents the tagname for the device (s) being polled for a process variable used internally for some compensation (e.g. pressure comp) . |
0x33320126 | mmi_chan_assign_help_index_ver5 | This parameter identifies the physical output channel to be configured. Channel A is terminals 1 and 2,Channel B is terminals 3 and 4,and Channel C is terminals 5 and 6. |
0x33320128 | mmi_mass_flow_digital_cutoff_help_index_new | The mass flow rate below which the frequency/pulse output indicates zero flow,and below which totalizers stop counting. Cutoffs can also be configured for the mA output(s) (the AO cutoffs). An AO cutoff is active only if the process variable assigned to the output is mass flow or volume flow. |
0x33320129 | mmi_vol_flow_digital_cutoff_help_index_new | The volume flow rate below which the frequency/pulse output indicates zero flow,and below which totalizers stop counting. Cutoffs can also be configured for the mA output(s) (the AO cutoffs). An AO cutoff is active only if the process variable assigned to the output is mass flow or volume flow. |
0x33320132 | mmi_dataset_LPO_stiffness_help | Meter Verification dataset LPO stiffness. |
0x33320133 | mmi_dataset_RPO_stiffness_help | Meter Verification dataset RPO stiffness. |
0x33320134 | mmi_dataset_damping_help | Meter Verification dataset damping. |
0x33320135 | mmi_dataset_LPO_mass_help | Meter Verification dataset LPO mass. |
0x33320136 | mmi_dataset_RPO_mass_help | Meter Verification dataset RPO mass. |
0x33320175 | mmi_char_sensor_label | Characterize Sensor |
0x33330000 | overview_LABEL | Overview |
0x33330001 | configure_LABEL | Configure |
0x33330002 | service_tools_LABEL | Service Tools |
0x33330003 | primary_purpose_LABEL | Primary Purpose Variables |
0x33330004 | shortcuts_LABEL | Shortcuts |
0x33330006 | guided_setup_LABEL | Guided Setup |
0x33330007 | manual_setup_LABEL | Manual Setup |
0x33330008 | alert_setup_LABEL | Alert Setup |
0x3333000A | device_information_LABEL | Device Information |
0x3333000B | zero_cal_LABEL | Zero Calibration |
0x3333000C | trends_LABEL | Trends |
0x3333000D | alerts_LABEL | Alerts |
0x33330016 | mass_flow_unit_LABEL | Mass Flow Unit |
0x33330017 | vol_flow_unit_LABEL | Volume Flow Unit |
0x33330018 | dens_unit_LABEL | Density Unit |
0x33330019 | temperature_unit_LABEL | Temperature Unit |
0x3333001A | flow_direction_LABEL | Flow Direction |
0x33330020 | characterize_LABEL | Characterize |
0x33330021 | measurements_LABEL | Measurements |
0x33330022 | inputs_output_LABEL | Inputs/Outputs |
0x33330023 | comms_LABEL | Communications |
0x33330024 | density_cal_LABEL | Density Calibration |
0x33330025 | temp_cal_LABEL | Temperature Calibration |
0x33330027 | setup_special_units_LABEL | Set Up Special Units |
0x33330028 | trim_output_LABEL | Trim mA Output |
0x33330029 | tag_parameters_LABEL | Sensor Tag Parameters |
0x3333002B | display_menu_features_LABEL | Display Variable Menu Features |
0x3333002D | backlight_LABEL | Backlight |
0x3333002E | setup_display_vars_LABEL | Set Up Display Variables |
0x33330037 | setup_DI_LABEL | Set Up Discrete Input |
0x33330038 | map_vars_LABEL | Map Variables |
0x3333003C | hart_comm_LABEL | HART Communications |
0x3333003D | ext_polling_LABEL | External Polling |
0x3333003E | setup_burst_LABEL | Set Up Burst Mode |
0x3333003F | zero_settings_LABEL | Settings |
0x33330046 | active_detail_LABEL | Active Detail |
0x33330048 | process_vars_LABEL | Process Variables |
0x3333004B | external_vars_LABEL | External Variables |
0x3333004D | diagnostic_vars_LABEL | Diagnostic Variables |
0x3333004E | routine_maint_LABEL | Routine Maintenance |
0x3333004F | sim_LABEL | Simulate |
0x33330050 | sim_outputs_LABEL | Simulate Outputs |
0x33330051 | sim_sensor_LABEL | Simulate Sensor |
0x33330052 | diagnostic_var_LABEL | Diagnostic Variable |
0x33330054 | vol_flow_rate_LABEL | Volume Flow Rate |
0x33330055 | lpo_voltage_LABEL | Left Pickoff Amplitude |
0x33330056 | rpo_voltage_LABEL | Right Pickoff Amplitude |
0x3333005A | freq_output_test_LABEL | Frequency Output Test |
0x3333005B | freq_test_description_LABEL | Set a fixed output value for the frequency output. |
0x3333005F | output_option_board_LABEL | Option Board |
0x33330060 | mass_total_LABEL | Mass Total |
0x33330061 | mass_inventory_LABEL | Mass Inventory |
0x33330062 | reset_volume_total_LABEL | Reset Volume Total |
0x33330063 | volume_total_LABEL | Volume Total |
0x33330065 | temp_t_series_LABEL | Meter Temperature (T-Series) |
0x33330066 | vol_inventory_LABEL | Volume Inventory |
0x3333006B | alert_description_a001_LABEL | An uncorrectable checksum mismatch has been detected. |
0x3333006C | recommended_action_a001_LABEL | Recommended Actions:\n1. Cycle power to the flow meter.\n2. The flow meter might need service. Contact Micro Motion. |
0x3333006D | alert_description_a002_LABEL | ROM checksum error or a RAM location cannot be written to. |
0x3333006E | alert_description_a003_LABEL | Continuity failure of drive circuit,LPO,or RPO,or LPO-RPO mismatch when driving. |
0x33330072 | alert_description_a005_LABEL | The measured flow has exceeded the maximum flow rate of the sensor. |
0x33330076 | alert_description_a008_LABEL | The measured density has exceeded 0-10 g/cm3. |
0x33330078 | alert_description_a009_LABEL | Transmitter in power-up mode. |
0x3333007A | alert_description_a010_LABEL | Mechanical zero: The resulting zero was greater than 3 microseconds.\nTemperature or Density Calibrations: many possible causes. |
0x3333007C | alert_description_a011_LABEL | Mechanical zero: Calibration procedure failed due to reverse flow through the sensor. |
0x3333007F | alert_description_a014_LABEL | Many possible causes. |
0x33330081 | alert_description_a016_LABEL | The value computed for the resistance of the Line RTD is outside limits. |
0x33330082 | alert_description_a017_LABEL | The value computed for the resistance of the Meter/Case RTD is outside limits. |
0x33330084 | alert_description_a020_LABEL | The flow calibration factor and/or K1 has not been entered since the last master reset. |
0x33330086 | alert_description_a021_LABEL | The sensor is recognized as a straight tube but the K1 value indicates a curved tube,or vice versa. |
0x33330088 | alert_description_a033_LABEL | No signal from Left Pickoff or Right Pickoff,suggesting that sensor tubes are not vibrating. |
0x3333008A | alert_description_a100_LABEL | The calculated amount of current output is outside of the linear range. |
0x3333008B | recommended_action_a100_LABEL | Recommended Actions:\n1. Verify that mA output range values are set to appropriate values. |
0x3333008C | alert_description_a101_LABEL | Non-zero HART address configured,or user has set the mA output to a fixed value. |
0x3333008E | alert_description_a102_LABEL | The drive power (current/voltage) is at its maximum. |
0x33330090 | alert_description_a104_LABEL | A calibration procedure is in progress. |
0x33330092 | alert_description_a105_LABEL | The density has exceeded the user-defined slug (density) limits. |
0x33330094 | alert_description_a106_LABEL | Device is in HART burst mode. |
0x33330096 | alert_description_a107_LABEL | The transmitter has been restarted. |
0x33330097 | alert_description_a108_LABEL | Event 1 has been triggered. |
0x33330098 | alert_description_a109_LABEL | Event 2 has been triggered. |
0x3333009B | alert_description_a111_LABEL | User has set the frequency output to a fixed value. |
0x3333009D | alert_description_a115_LABEL | No response received from polled device. |
0x3333009E | recommended_action_a115_LABEL | Recommended Actions:\n1. HART polling connection to external device has failed. Ensure that external device is available:\n2. Verify device operation.\n3. Verify wiring.\n4. Verify polling configuration. |
0x3333009F | alert_description_a118_LABEL | The user has set the discrete output to a fixed state. |
0x333300A2 | alert_description_a132_LABEL | Simulation mode is enabled. |
0x333300A4 | alert_description_discrete_event_1_active_LABEL | Discrete Event 1 has been triggered. |
0x333300A5 | alert_description_discrete_event_2_active_LABEL | Discrete Event 2 has been triggered. |
0x333300A6 | alert_description_discrete_event_3_active_LABEL | Discrete Event 3 has been triggered. |
0x333300A7 | alert_description_discrete_event_4_active_LABEL | Discrete Event 4 has been triggered. |
0x333300A8 | alert_description_discrete_event_5_active_LABEL | Discrete Event 5 has been triggered. |
0x333300AA | alert_description_discrete_input_active_LABEL | Discrete Input is active. |
0x333300AB | recommended_action_no_action_required_LABEL | Recommended Actions:\n1. No action required. |
0x333300AC | alert_description_pv_out_of_limits_LABEL | Primary variable has exceeded sensor limits. |
0x333300AD | recommended_action_pv_out_of_limits_LABEL | Recommended Actions:\n1. Verify process and check for slug flow.\n2. Check the test points.\n3. Check the sensor circuitry.\n4. Check the sensor tubes for erosion.\n5. If the problem persists,contact Micro Motion. |
0x333300AE | alert_description_non_pv_out_of_limits_LABEL | Non-primary variable has exceeded sensor limits. |
0x333300AF | alert_description_cold_start_LABEL | Power has been removed and reapplied resulting in the reinstallations of the setup information. |
0x333300B0 | recommended_action_cold_start_LABEL | Recommended Actions:\n1. The first command to recognize this condition will automatically reset this flag.\n2. This flag may also be set following a Master Reset or a Self Test. |
0x333300B2 | alert_description_device_malfunction_LABEL | A hardware error or failure has been detected by the device. |
0x333300B3 | recommended_action_device_malfunction_LABEL | Recommended Actions:\n1. Check the test points.\n2. Check the sensor circuitry.\n3. If the problem persists,contact Micro Motion. |
0x333300B4 | alert_description_a029_LABEL | Transmitter electronics failure has occurred. |
0x333300B5 | recommended_action_a029_LABEL | Recommended Actions:\n1. Cycle power to the flowmeter.\n2. Contact Micro Motion. |
0x333300B6 | alert_description_a030_LABEL | The loaded software is not compatible with the programmed board type. |
0x333300B7 | recommended_action_a030_LABEL | Recommended Actions:\n1. Contact Micro Motion. |
0x333300B8 | alert_description_a031_LABEL | The core processor is not receiving enough power. |
0x333300BD | no_active_alerts_LABEL | No Active Alerts |
0x333300BE | display_total_reset_LABEL | Totalizer Reset |
0x333300BF | display_total_start_stop_LABEL | Start/Stop Totalizers |
0x333300C0 | backlight_intensity_LABEL | Intensity (0-63) |
0x333300C1 | update_period_LABEL | Update Period (100-10,000) |
0x333300C2 | scroll_rate_LABEL | Scroll Time (1-10) |
0x333300C3 | offline_password_LABEL | Passcode (4 Digits) |
0x333300C8 | assign_discrete_action | Assign Discrete Action |
0x333300CD | present_freq_out_LABEL | Present Frequency Output |
0x333300CE | ext_temp_LABEL | External Temperature |
0x333300CF | percent_range_current_LABEL | Percent Range/Current |
0x333300D0 | process_vars_current_LABEL | Process Variables/Current |
0x333300D1 | field_device_var_LABEL | Field Device Variables |
0x333300D3 | cal_tag_example_LABEL | Calibration Tag Example: |
0x333300D5 | channel_A_power_LABEL | Channel A Power Source |
0x333300D6 | channel_B_power_LABEL | Channel B Power Source |
0x333300D8 | mA_fault_action_LABEL | mA Output Fault Action |
0x333300DC | max_pulse_width_LABEL | Maximum Pulse Width |
0x333300DD | fo_polarity_LABEL | Frequency Output Polarity |
0x333300DE | fo_fault_action_LABEL | Frequency Output Fault Action |
0x333300E0 | fo_scale_method_LABEL | Frequency Output Scaling Method |
0x333300E1 | frequency_factor_LABEL | Frequency Factor |
0x333300E2 | rate_factor_LABEL | Rate Factor |
0x333300E3 | setup_do_LABEL | Set Up Discrete Output |
0x333300E5 | discrete_output_assignment_LABEL | Assignment |
0x333300E6 | discrete_output_state_LABEL | Discrete Output State |
0x333300E7 | discrete_output_polarity_LABEL | Polarity |
0x333300EB | discrete_output_fault_action_LABEL | Fault Action |
0x333300ED | flow_switch_var_LABEL | Source |
0x333300EE | frequency_output_LABEL | Frequency Output |
0x333300F0 | auto_scroll_LABEL | Auto Scroll |
0x333300F1 | offline_menu_LABEL | Offline Menu |
0x333300F2 | alarm_menu_LABEL | Alert Menu |
0x333300F3 | ack_all_LABEL | Acknowledge All Alarms |
0x333300F4 | offline_password_enable_LABEL | Passcode Required |
0x333300F5 | fault_timeout_LABEL | Fault Timeout |
0x333300F6 | digi_comm_fault_action_LABEL | Digital Communications Fault Action |
0x333300F7 | internal_all_zero_LABEL | Internal Zero - All 0 |
0x333300F8 | internal_flow_zero_LABEL | Internal Zero - Flow 0 |
0x333300FE | enable_ext_temp_LABEL | Enable External Temperature |
0x333300FF | temp_damping_LABEL | Temperature Damping |
0x33330100 | enable_press_comp_LABEL | Enable Pressure Compensation |
0x33330101 | flow_press_factor_LABEL | Flow Pressure Factor |
0x33330102 | density_press_factor_LABEL | Density Pressure Factor |
0x33330103 | flow_cal_pressure_LABEL | Flow Calibration Pressure |
0x33330104 | base_mass_unit_LABEL | Base Mass Unit |
0x33330105 | base_mass_time_LABEL | Base Mass Time |
0x33330106 | mass_flow_conv_factor_LABEL | Conversion Factor |
0x33330107 | mass_flow_text_LABEL | Flow Label |
0x33330108 | mass_total_text_LABEL | Total Label |
0x33330109 | base_vol_unit_LABEL | Base Volume Unit |
0x3333010A | base_vol_time_LABEL | Base Volume Time |
0x3333010B | vol_flow_conv_factor_LABEL | Conversion Factor |
0x3333010C | vol_flow_text_LABEL | Flow Label |
0x3333010D | vol_total_text_LABEL | Total Label |
0x33330111 | ext_device_tag_1_LABEL | External Device Tag 1 |
0x33330112 | ext_device_tag_2_LABEL | External Device Tag 2 |
0x33330114 | temp_cal_factor_LABEL | Temperature Calibration Factor |
0x33330115 | burst_mode_LABEL | Mode |
0x33330116 | final_assembly_number_LABEL | Final Assembly Number |
0x33330118 | software_revision_LABEL | Transmitter Software Revision |
0x33330119 | polling_address_LABEL | HART Address |
0x3333011B | burst_option_LABEL | Option |
0x3333011C | burst_var_1_LABEL | Field Device Variable 1 |
0x3333011D | burst_var_2_LABEL | Field Device Variable 2 |
0x3333011E | burst_var_3_LABEL | Field Device Variable 3 |
0x3333011F | burst_var_4_LABEL | Field Device Variable 4 |
0x33330120 | mass_flow_cutoff_LABEL | Mass Flow Cutoff |
0x33330121 | mass_flow_analog_value_LABEL | Mass Flow mA Value |
0x33330122 | added_damping_LABEL | Added Damping |
0x33330123 | mass_flow_percent_range_LABEL | Mass Flow Percent Range |
0x33330124 | mass_flow_URV_LABEL | Mass Flow Upper Range Value |
0x33330125 | mass_flow_LRV_LABEL | Mass Flow Lower Range Value |
0x33330126 | flow_damping_LABEL | Flow Damping |
0x33330127 | sensor_serial_number_LABEL | Sensor Serial Number |
0x33330128 | mass_flow_USL_LABEL | Mass Flow Upper Sensor Limit |
0x33330129 | mass_flow_LSL_LABEL | Mass Flow Lower Sensor Limit |
0x3333012A | mass_flow_min_span_LABEL | Mass Flow Minimum Span |
0x3333012B | density_cutoff_LABEL | Density Cutoff |
0x3333012C | density_damping_LABEL | Density Damping |
0x3333012D | vol_flow_cutoff_LABEL | Volume Flow Cutoff |
0x33330130 | slug_high_LABEL | Slug High Limit |
0x33330131 | slug_low_LABEL | Slug Low Limit |
0x33330132 | slug_duration_LABEL | Slug Duration |
0x33330133 | flow_cal_LABEL | FlowCal |
0x33330134 | mA_cutoff_LABEL | mA Output Flow Rate Cutoff |
0x33330137 | zero_value_LABEL | Zero Value |
0x33330138 | std_deviation_LABEL | Standard Deviation |
0x33330139 | internal_zero_LABEL | Internal Zero |
0x3333013A | mass_factor_LABEL | Mass Factor |
0x3333013B | vol_factor_LABEL | Volume Factor |
0x3333013C | density_factor_LABEL | Density Factor |
0x3333013D | live_zero_flow_LABEL | Live Zero Flow Rate |
0x3333013E | TC_LABEL | TC |
0x3333013F | display_var_1_LABEL | Position 1 |
0x33330140 | display_var_2_LABEL | Position 2 |
0x33330141 | display_var_3_LABEL | Position 3 |
0x33330142 | display_var_4_LABEL | Position 4 |
0x33330143 | display_var_5_LABEL | Position 5 |
0x33330144 | display_var_6_LABEL | Position 6 |
0x33330145 | display_var_7_LABEL | Position 7 |
0x33330146 | display_var_8_LABEL | Position 8 |
0x33330147 | display_var_9_LABEL | Position 9 |
0x33330148 | display_var_10_LABEL | Position 10 |
0x33330149 | display_var_11_LABEL | Position 11 |
0x3333014A | display_var_12_LABEL | Position 12 |
0x3333014B | display_var_13_LABEL | Position 13 |
0x3333014C | display_var_14_LABEL | Position 14 |
0x3333014D | display_var_15_LABEL | Position 15 |
0x33330150 | zero_time_LABEL | Zero Time |
0x33330152 | u16_value_LABEL | U16 Value |
0x33330153 | u32_value_LABEL | U32 Value |
0x33330154 | float_value_LABEL | Float Value |
0x33330155 | exception_code_LABEL | Exception Code |
0x33330156 | timestamp_LABEL | Timestamp of Status Change |
0x33330157 | lpo_stiffness_mean_LABEL | Left Pickoff Stiffness Mean |
0x33330158 | rpo_stiffness_mean_LABEL | Right Pickoff Stiffness Mean |
0x33330159 | damping_mean_LABEL | Damping Mean |
0x3333015A | lpo_mass_mean_LABEL | Left Pickoff Mass Mean |
0x3333015B | rpo_mass_mean_LABEL | Right Pickoff Mass Mean |
0x3333015C | DD_revision_LABEL | DD Revision |
0x33330160 | advisory_LABEL | Advisory |
0x33330163 | device_status_good_LABEL | Device Status: Good |
0x33330164 | device_status_failed_LABEL | Device Status: Failed |
0x33330165 | device_status_advisory_LABEL | Device Status: Advisory |
0x33330166 | device_status_maint_LABEL | Device Status: Maintenance |
0x33330167 | comm_status_polled_LABEL | Communication Status: Polled |
0x33330168 | comm_status_burst_LABEL | Communication Status: Burst |
0x3333016B | setup_fo_description_LABEL | Assign a variable to the frequency output,set maximum pulse width,polarity and scaling. |
0x33330170 | pressure_unit_LABEL | Pressure Unit |
0x33330171 | sim_mass_flow_rate_LABEL | Simulate Mass Flow Rate |
0x33330173 | ext_pressure_LABEL | External Pressure |
0x3333017B | temperature_analog_value_LABEL | Temperature mA Value |
0x3333017C | density_analog_value_LABEL | Density mA Value |
0x3333017D | vol_flow_analog_value_LABEL | Volume Flow mA Value |
0x3333017E | temperature_percent_range_LABEL | Temperature Percent Range |
0x3333017F | density_percent_range_LABEL | Density Percent Range |
0x33330180 | vol_flow_percent_range_LABEL | Volume Flow Percent Range |
0x33330182 | sim_temp_LABEL | Simulate Temperature |
0x33330184 | sim_density_LABEL | Simulate Density |
0x33330186 | gas_vol_flow_rate_LABEL | Gas Standard Volume Flow Rate |
0x33330187 | gas_vol_total_LABEL | Gas Standard Volume Total |
0x33330188 | gas_vol_inventory_LABEL | Gas Standard Volume Inventory |
0x333301A2 | materials_of_construction_LABEL | Materials of Construction |
0x333301AC | mmi_char_sensor_LABEL | Characterize Sensor |
0x333301B3 | perform_auto_zero_LABEL | Perform Auto Zero |
0x333301B4 | start_totalizers_LABEL | Start |
0x333301B5 | stop_totalizers_LABEL | Stop |
0x333301B6 | reset_all_totals_LABEL | Reset All |
0x333301B7 | ack_all_alerts_LABEL | Acknowledge All Alerts |
0x333301BD | start_meter_ver_LABEL | Starting meter verification,please wait. |
0x333301BE | meter_ver_pass_LABEL | Meter verification PASSED.\nMeter meets factory specifications. |
0x333301BF | meter_ver_failed_LABEL | Meter Verification FAILED.\nMeter may not meet factory specifications.\nPress Help for more Information. |
0x333301C0 | meter_ver_error_LABEL | Meter verification error. |
0x333301C1 | freq_factor_hz_LABEL | Frequency Factor (Hz) |
0x333301C2 | pulses_per_unit_LABEL | Pulses Per Unit |
0x333301C3 | units_per_pulse_LABEL | Units Per Pulse |
0x333301C4 | reset_config_change_flag_LABEL | Reset Configuration Changed Flag |
0x333301CE | fo_settings_LABEL | Frequency Output Settings |
0x333301CF | discrete_output_LABEL | Discrete Output |
0x333301D0 | DD_device_rev_LABEL | Device Revision |
0x333301D2 | hart_dd_info_LABEL | HART DD Information |
0x333301D3 | discrete_input_LABEL | Discrete Input |
0x333301D8 | step2_display_vars_LABEL | Display Variables |
0x333301E2 | display_vars_1_5_LABEL | Display Variables (1 - 5) |
0x333301E3 | display_vars_6_10_LABEL | Display Variables (6 - 10) |
0x333301E4 | display_vars_11_15_LABEL | Display Variables (11 - 15) |
0x333301E5 | alert_settings_LABEL | Alert Settings |
0x333301E6 | fo_fault_params_LABEL | Frequency Output Fault Parameters |
0x333301E7 | fo_scaling_LABEL | Frequency Output Scaling |
0x333301E9 | sensor_info_LABEL | Sensor Information |
0x333301EC | licenses_LABEL | Licenses |
0x333301ED | failed_fix_now_LABEL | Failed - Fix Now |
0x333301EE | maint_fix_soon_LABEL | Maintenance - Fix Soon |
0x333301EF | a001_LABEL | A001: EEPROM Error (Core Processor) |
0x333301F0 | a002_LABEL | A002: RAM Error (Core Processor) |
0x333301F1 | a003_LABEL | A003: No Sensor Response |
0x333301F2 | a004_LABEL | A004: Temperature Overrange |
0x333301F3 | a005_LABEL | A005: Mass Flow Overrange |
0x333301F4 | a006_LABEL | A006: Characterization Required |
0x333301F5 | a008_LABEL | A008: Density Overrange |
0x333301F6 | a009_LABEL | A009: Transmitter Initializing/Warming Up |
0x333301F7 | a010_LABEL | A010: Calibration Failure |
0x333301F8 | a011_LABEL | A011: Zero Calibration Failed: Low |
0x333301F9 | a012_LABEL | A012: Zero Calibration Failed: High |
0x333301FA | a013_LABEL | A013: Zero Calibration Failed: Unstable |
0x333301FB | a014_LABEL | A014: Transmitter Failure |
0x333301FC | a016_LABEL | A016: Sensor RTD Failure |
0x333301FD | a017_LABEL | A017: T-Series RTD Failure |
0x333301FE | a020_LABEL | A020: No Flow Calibration Value |
0x333301FF | a021_LABEL | A021: No K1 Value |
0x33330200 | a029_LABEL | A029: PIC/Daughterboard Communication Failure |
0x33330201 | a030_LABEL | A030: Incorrect Board Type |
0x33330202 | a031_LABEL | A031: Low Power |
0x33330203 | a032_LABEL | A032: Meter Verification in Progress: Outputs to Fault |
0x33330204 | a033_LABEL | A033: No Right/Left Pickoff Signal |
0x33330205 | a100_LABEL | A100: mA Output Saturated |
0x33330206 | a101_LABEL | A101: mA Output Fixed |
0x33330207 | a102_LABEL | A102: Drive Overrange |
0x33330208 | a104_LABEL | A104: Calibration In Progress |
0x33330209 | a105_LABEL | A105: Slug Flow |
0x3333020A | a106_LABEL | A106: Burst Mode Enabled |
0x3333020B | a107_LABEL | A107: Power Reset Occurred |
0x3333020C | a108_LABEL | A108: Single-Setpoint Event 1 ON |
0x3333020D | a109_LABEL | A109: Single-Setpoint Event 2 ON |
0x3333020E | a110_LABEL | A110: Frequency Output Saturated |
0x3333020F | a111_LABEL | A111: Frequency Output Fixed |
0x33330210 | a115_LABEL | A115: No External Input or Polled Data |
0x33330211 | a118_LABEL | A118: Discrete Output Fixed |
0x33330212 | a131_LABEL | A131: Meter Verification in Progress: Outputs to Last Measured Value |
0x33330213 | a132_LABEL | A132: Sensor Simulation Active |
0x33330214 | grp_alert_discrete_event_1_active_LABEL | Discrete Event 1 Active |
0x33330215 | grp_alert_discrete_event_2_active_LABEL | Discrete Event 2 Active |
0x33330216 | grp_alert_discrete_event_3_active_LABEL | Discrete Event 3 Active |
0x33330217 | grp_alert_discrete_event_4_active_LABEL | Discrete Event 4 Active |
0x33330218 | grp_alert_discrete_event_5_active_LABEL | Discrete Event 5 Active |
0x33330219 | discrete_in_active_LABEL | Discrete Input Active |
0x3333021A | primary_var_out_of_limits_LABEL | Primary Variable Out of Limits |
0x3333021B | non_primary_var_out_of_limits_LABEL | Non-Primary Variable Out of Limits |
0x3333021C | pv_mA_saturated_LABEL | Primary Variable mA Output Saturated |
0x3333021D | pv_mA_fixed_LABEL | Primary Variable mA Output Fixed |
0x3333021E | cold_start_LABEL | Cold Start |
0x3333021F | config_changed_LABEL | Configuration Changed |
0x33330220 | field_device_malfunction_LABEL | Field Device Malfunction |
0x33330221 | vars_polled_LABEL | Variables Polled from External Devices |
0x33330223 | discrete_actions_LABEL | Discrete Actions |
0x33330225 | gsv_special_units_LABEL | Special Gas Standard Volume Units |
0x33330227 | gsv_total_inv_unit_LABEL | Gas Standard Volume Total/Inventory Unit |
0x33330228 | gsv_cutoff_LABEL | Gas Standard Volume Cutoff |
0x3333022A | liquid_volume_LABEL | Liquid Volume |
0x3333022B | gsv_flow_rate_LABEL | Gas Standard Volume Flow Rate |
0x33330231 | dens_LRV_LABEL | Density Lower Range Value |
0x33330232 | lrv_LABEL | Lower Range Value |
0x33330233 | temp_LRV_LABEL | Temperature Lower Range Value |
0x33330234 | dens_URV_LABEL | Density Upper Range Value |
0x33330235 | urv_LABEL | Upper Range Value |
0x33330236 | vol_flow_LRV_LABEL | Volume Flow Lower Range Value |
0x33330237 | temp_USL_LABEL | Temperature Upper Sensor Limit |
0x33330238 | lsl_LABEL | Lower Sensor Limit |
0x33330239 | dens_LSL_LABEL | Density Lower Sensor Limit |
0x3333023A | vol_flow_USL_LABEL | Volume Flow Upper Sensor Limit |
0x3333023B | temp_LSL_LABEL | Temperature Lower Sensor Limit |
0x3333023C | dens_min_span_LABEL | Density Minimum Span |
0x3333023D | min_span_LABEL | Minimum Span |
0x3333023E | vol_flow_min_span_LABEL | Volume Flow Minimum Span |
0x3333023F | usl_LABEL | Upper Sensor Limit |
0x33330240 | dens_USL_LABEL | Density Upper Sensor Limit |
0x33330241 | temp_min_span_LABEL | Temperature Minimum Span |
0x33330242 | vol_flow_URV_LABEL | Volume Flow Upper Range Value |
0x33330243 | temp_URV_LABEL | Temperature Upper Range Value |
0x33330244 | vol_flow_LSL_LABEL | Volume Flow Lower Sensor Limit |
0x33330247 | api_density_digital_value_LABEL | Temperature-Corrected Density (Petroleum) |
0x3333024A | api_vars_LABEL | Petroleum Measurement Variables |
0x3333024B | api_volume_flow_digital_value_LABEL | Temperature-Corrected Volume Flow Rate (Petroleum) |
0x3333024C | api_volume_inventory_digital_value_LABEL | Temperature-Corrected Volume Inventory (Petroleum) |
0x3333024D | api_volume_total_digital_value_LABEL | Temperature-Corrected Volume Total (Petroleum) |
0x3333024F | ed_vars_LABEL | Variables (Concentration Measurement) |
0x33330250 | ed_conc_digital_value_LABEL | Concentration |
0x33330251 | ed_dens_ref_digital_value_LABEL | Density at Reference (Concentration) |
0x33330252 | ed_dens_sgu_digital_value_LABEL | Specific Gravity (Concentration) |
0x33330253 | ed_net_mass_flow_digital_value_LABEL | Net Mass Flow Rate (Concentration) |
0x33330254 | ed_net_mas_total_digital_value_LABEL | Net Mass Total (Concentration) |
0x33330255 | ed_net_mas_inventory_digital_value_LABEL | Net Mass Inventory (Concentration) |
0x33330258 | ed_net_volume_flow_digital_value_LABEL | Net Volume Flow Rate (Concentration) |
0x33330259 | ed_net_volume_inventory_digital_value_LABEL | Net Volume Inventory (Concentration) |
0x3333025B | ed_net_volume_total_digital_value_LABEL | Net Volume Total (Concentration) |
0x3333025D | ed_std_volume_flow_digital_value_LABEL | Temperature-Corrected Volume Flow Rate (Concentration) |
0x3333025E | ed_std_volume_inventory_digital_value_LABEL | Temperature-Corrected Volume Inventory (Concentration) |
0x3333025F | ed_std_volume_total_digital_value_LABEL | Temperature-Corrected Volume Total (Concentration) |
0x33330260 | ed_variable_LABEL | Concentration Measurement |
0x33330262 | ed_dens_baume_digital_value_LABEL | Baume (Concentration) |
0x33330268 | perform_factory_zero_LABEL | Restore Factory Zero |
0x3333026A | setup_rs485_LABEL | Set Up RS-485 Port |
0x3333026C | str_set_FO_scaling_LABEL | Set Frequency Output Scaling |
0x33330279 | conc_msmt_vars_LABEL | Concentration Measurement Variables |
0x3333027B | density_units_LABEL | Density Unit (Concentration) |
0x3333027C | sec_LABEL | sec |
0x33330281 | rs485_protocol_LABEL | Protocol |
0x33330282 | rs485_baudrate_LABEL | Baud Rate |
0x33330283 | rs485_parity_LABEL | Parity |
0x33330284 | rs485_stop_LABEL | Stop Bits |
0x33330285 | modbus_address_LABEL | Modbus Slave Address |
0x33330294 | hast_c_LABEL | Hastelloy-C |
0x33330295 | stainless_steel_316L_LABEL | 316L Stainless Steel |
0x33330297 | sanitary_clamp_fitting_LABEL | Sanitary Clamp Fitting |
0x3333029B | mA_output_2_LABEL | mA Output 2 |
0x3333029F | discrete_output_2_LABEL | Discrete Output 2 |
0x333302A4 | mA_output_1_fault_LABEL | mA Output 1 Fault Settings |
0x333302A5 | mA_output_2_fault_LABEL | mA Output 2 Fault Settings |
0x333302CC | blank_text | |
0x333302CD | percent_constant_unit | % |
0x333302CF | mV_Hz_constant_unit | mV/Hz |
0x333302D0 | Hz_constant_unit | Hz |
0x333302D1 | Volts_constant_unit | V |
0x333302DB | CEQ_Number_LABEL | Engineer to Order Number |
0x333302DC | extended_fld_device_status_LABEL | Extended Device Status |
0x333302E4 | grp_config_flow_switch_LABEL | Flow Switch |
0x333302E5 | grp_device_id_LABEL | Device Identification |
0x333302E7 | extended_fld_device_status_help | Provides additional Device Status information |
0x333302EA | grp_custody_transfer_LABEL | Custody Transfer |
0x333302EB | tab_weights_and_measures_LABEL | Weights and Measures |
0x333302EC | set_totalizer_reset_option_LABEL | Set Totalizer Reset Option |
0x333302ED | World_area_weights_measures_security_LABEL | Custody Transfer Approval |
0x333302EE | set_totalizer_reset_option_case_0_LABEL | NTEP does not allow changing of this parameter |
0x333302EF | select_totalizer_reset_option_LABEL | Select Totalizer Reset Option |
0x333302F8 | PM_vars_LABEL | Petroleum Measurement |
0x333302F9 | reset_total_LABEL | Reset Total |
0x333302FA | flow_rate_LABEL | Flow Rate |
0x333302FB | total_LABEL | Total |
0x333302FC | cust_trans_totalizer_reset_option_LABEL | Totalizer Reset Option |
0x333302FD | CM_vol_at_ref_temp_LABEL | CM Volume at Reference Temperature |
0x333302FE | CM_net_mass_LABEL | CM Net Mass |
0x333302FF | CM_net_volume_LABEL | CM Net Volume |
0x33330300 | PM_vol_ref_LABEL | Temperature-Corrected Volume (Petroleum) |
0x33330301 | sens_type_other_LABEL | Other (Curved Tube) |
0x33330302 | sens_type_tseries_LABEL | T-Series (Straight Tube) |
0x33330303 | fcf_tseries_LABEL | Flow FCF |
0x33330304 | new_style_sensor_tag_LABEL | Calibration Tag Example:\nNew Style Sensor Tag |
0x33330305 | old_style_sensor_tag_LABEL | \nOld Style Sensor Tag |
0x33330307 | tertiary_variable_code_LABEL | Third Variable |
0x33330308 | fourth_variable_code_LABEL | Fourth Variable |
0x33330309 | first_dens_cal_LABEL | First Point Calibration |
0x3333030A | second_dens_cal_LABEL | Second Point Calibration |
0x3333030B | third_dens_cal_LABEL | Third Point Calibration |
0x3333030C | fourth_dens_cal_LABEL | Fourth Point Calibration |
0x3333030D | flowing_dens_cal_LABEL | Flowing Density Calibration |
0x3333030E | temp_cal_factor_description_LABEL | The Temperature Calibration Factor is a 14 character string that contains two real numbers.\nThe first number, before the T, is the slope.\nThe slope must be a positive real number containing 7 characters (including the decimal point).\nThe T is a delimiter and must be present.\nThe second number, after the T, is the offset.\nThe offset must be a real number containing 7 characters (including the decimal point and negative sign if present).\nThe offset must be between -10 and +10. |
0x33330312 | mapped_vars_LABEL | Mapped Variables |
0x33330313 | meth_characterize_sensor_description_LABEL | Configure the transmitter for sensor characteristics. |
0x33330315 | meth_perform_loop_tests_description_LABEL | Set fixed value for the milliamp,frequency and discrete outputs. |
0x33330317 | meth_perform_loop_tests_LABEL | Perform Loop Tests |
0x33330318 | api_ctl_table_type_LABEL | 2540 CTL Table Type |
0x33330319 | api_thermal_exp_coeff_LABEL | Thermal Expansion Coefficient |
0x3333031A | api_ref_temp_LABEL | Reference Temperature |
0x3333031B | api_setup_LABEL | Petroleum Measurement Set Up |
0x3333031C | ext_compensation_LABEL | External Compensation |
0x3333031D | PM_density_digital_value_LABEL | Density at Reference Temperature |
0x3333031E | PM_volume_flow_digital_value_LABEL | Volume Flow at Ref Temperature |
0x3333031F | PM_avg_density_digital_value_LABEL | Average Observed Density |
0x33330320 | PM_avg_temperature_digital_value_LABEL | Average Observed Temperature |
0x33330321 | CM_std_volume_flow_digital_value_LABEL | Standard Volume Flow Rate |
0x33330322 | CM_net_mass_flow_digital_value_LABEL | Net Mass Flow Rate |
0x33330323 | CM_net_volume_flow_digital_value_LABEL | Standard Net Volume Flow Rate |
0x33330324 | CM_dens_ref_digital_value_LABEL | Density at Reference |
0x33330325 | CM_dens_sgu_digital_value_LABEL | Density (Fixed SG Units) |
0x33330326 | details_LABEL | Details |
0x33330327 | offline_var_menu_features_LABEL | Offline Variable Menu Features |
0x33330328 | str_auto_loop_LABEL | Warning: Take the device out of process control loop. |
0x33330329 | device_process_loop_position_LABEL | Device is in process control loop;Device is out of process control loop |
0x3333032A | str_return_auto_LABEL | It is now safe to put the device in process control loop. |
0x3333032B | str_return_out_LABEL | Returning field device to original output. |
0x3333032C | str_at_4ma_LABEL | Is field device 4.00 mA output equal to reference meter? |
0x3333032D | str_at_20ma_LABEL | Is field device 20.00 mA output equal to reference meter? |
0x3333032E | choose_PM_table_number_LABEL | Choose Petroleum Measurement Table Number: |
0x3333032F | choose_PM_table_letter_LABEL | Choose Petroleum Measurement Table Letter: |
0x33330330 | dens_cal_factor_description_LABEL | The DensCal Factor field on the old style sensor tag contains the K1,K2 and TC values.\nThe first 5 characters are K1,the second 5 characters are K2 and the remaining characters are TC. |
0x33330336 | perform_zero_cal_description_LABEL | Perform auto zero or restore factory zero. |
0x33330337 | map_variables_description_LABEL | Assign variables to primary (PV),secondary (SV),third (TV) and fourth (QV) variables. |
0x33330338 | meth_view_alert_severity_LABEL | View Alert Severity |
0x33330339 | active_alerts_LABEL | Active Alerts |
0x3333033D | var_gsv_unit_LABEL | Gas Volume Flow Unit |
0x3333033E | gas_vol_flow_conversion_factor_LABEL | Conversion Factor |
0x3333033F | gas_vol_flow_text_LABEL | Flow Label |
0x33330340 | gas_vol_total_text_LABEL | Total Label |
0x33330341 | check_status_LABEL | Check Status |
0x33330342 | var_summary_LABEL | Variable Summary |
0x33330343 | flow_parameters_LABEL | Flow Parameters |
0x33330344 | density_parameters_LABEL | Density Parameters |
0x33330345 | setup_decimal_places_LABEL | Set Up Decimal Places |
0x33330348 | a018_LABEL | A018: EEPROM Error (Transmitter) |
0x33330349 | alert_description_a018_LABEL | The transmitter has experienced an EEPROM checksum failure. |
0x3333034B | a019_LABEL | A019: RAM Error (Transmitter) |
0x3333034C | alert_description_a019_LABEL | A RAM location in the transmitter cannot be written to. |
0x3333034E | a022_LABEL | A022: Configuration Database Corrupt (Core Processor) |
0x3333034F | alert_description_a022_LABEL | Uncorrectable checksum mismatch. |
0x33330350 | recommended_action_a022_LABEL | Recommended Actions:\n1.Cycle power to the flowmeter.\n2.The transmitter might need service. Contact Micro Motion. |
0x33330351 | a023_LABEL | A023: Internal Totals Corrupt (Core Processor) |
0x33330352 | alert_description_a023_LABEL | Uncorrectable checksum mismatch. |
0x33330353 | recommended_action_a023_LABEL | Recommended Actions:\n1.Cycle power to the flowmeter.\n2.The transmitter might need service. Contact Micro Motion. |
0x33330354 | a024_LABEL | A024: Program Corrupt (Core Processor) |
0x33330355 | alert_description_a024_LABEL | Uncorrectable checksum mismatch. |
0x33330356 | recommended_action_a024_LABEL | Recommended Actions:\n1.Cycle power to the flowmeter.\n2.The transmitter might need service. Contact Micro Motion. |
0x33330357 | a025_LABEL | A025: Boot Sector Fault (Core Processor) |
0x33330358 | alert_description_a025_LABEL | Uncorrectable checksum mismatch. |
0x33330359 | recommended_action_a025_LABEL | Recommended Actions:\n1.Cycle power to the flowmeter.\n2.The transmitter might need service. Contact Micro Motion. |
0x3333035A | a026_LABEL | A026: Sensor/Transmitter Communications Failure |
0x3333035B | alert_description_a026_LABEL | Communication errors between transmitter and core processor. |
0x3333035D | a027_LABEL | A027: Security Breach |
0x3333035E | alert_description_a027_LABEL | Weights and Measures security seal has been broken. |
0x3333035F | recommended_action_a027_LABEL | Recommended Actions:\n1. Alarm can be cleared by user,but authorized procedure is required to reestablish security. |
0x33330360 | a028_LABEL | A028: Core Processor Write Failure |
0x33330361 | alert_description_a028_LABEL | An attempt to write data to the core processor has failed. |
0x33330362 | recommended_action_a028_LABEL | Recommended Actions:\n1. Cycle power to the flowmeter.\n2. The transmitter might need service or upgrading. Contact Micro Motion. |
0x33330363 | a103_LABEL | A103: Data Loss Possible (Totals and Inventories) |
0x33330364 | alert_description_a103_LABEL | The core processor was unable to successfully store the totalizers and inventories on the last power down and must rely on the previously saved values. These values may be up to two hours old. |
0x33330366 | a116_LABEL | A116: Temperature Overrange (Petroleum) |
0x33330367 | alert_description_a116_LABEL | The process temperature is outside Petroleum Measurement defined extrapolation limits. |
0x33330369 | a117_LABEL | A117: Density Overrange (Petroleum) |
0x3333036A | alert_description_a117_LABEL | The process density is outside Petroleum Measurement defined extrapolation limits. |
0x3333036D | a120_LABEL | A120: Curve Fit Failure (Concentration) |
0x3333036E | alert_description_a120_LABEL | The configured density/temperature/concentration values do not result in a proper Concentration Measurement (CM) curve. |
0x33330370 | a121_LABEL | A121: Extrapolation Alarm (Concentration) |
0x33330371 | alert_description_a121_LABEL | The process temperature or density is outside the user-defined extrapolation limits. |
0x33330373 | alert_description_a004_new_LABEL | The value computed for the resistance of the line RTD or the Meter/Case RTD is outside limits. |
0x33330374 | alert_description_a006_new_LABEL | One or more required characterization parameters have not been entered. |
0x33330376 | alert_description_a012_LABEL | Mechanical zero: Calibration procedure failed due to flow through the sensor.\nThe resulting zero was greater than 3 microseconds. |
0x3333037B | decimal_places_LABEL | Decimal Places |
0x3333037C | decimal_places_for_process_vars_LABEL | Decimal Places for Process Variables |
0x3333037D | decimal_places_for_totalizer_vars_LABEL | Decimal Places for Totalizer Variables |
0x3333037E | decimal_places_for_diagnostic_vars_LABEL | Decimal Places for Diagnostic Variables |
0x3333037F | primary_var_description_LABEL | The first milliamp output uses the primary variable as its source. |
0x33330380 | secondary_var_description_LABEL | The second milliamp output uses the Secondary Variable as its source. |
0x33330381 | third_var_description_LABEL | The frequency output uses the third variable as its source. |
0x33330382 | event1_setpoint_LABEL | Event 1 Setpoint |
0x33330383 | event1_var_LABEL | Event 1 Variable |
0x33330384 | event1_type_LABEL | Event 1 Type |
0x33330385 | event2_setpoint_LABEL | Event 2 Setpoint |
0x33330386 | event2_var_LABEL | Event 2 Variable |
0x33330387 | event2_type_LABEL | Event 2 Type |
0x33330388 | str_flow_zero_do_cal_LABEL | Flow must be zero.\nYou are about to perform a zero calibration. |
0x33330397 | enable_sim_label_LABEL | Simulation Mode is %0 |
0x333303AD | sensor_type_option_LABEL | Other (Curved Tube);T-Series (Straight Tube) |
0x333303AE | parameters_updating_LABEL | Parameters are being updated,please wait... |
0x333303AF | select_freq_output_scaling_option_LABEL | Select Frequency Output Scaling Method: |
0x333303B0 | freq_output_scaling_option_LABEL | Frequency=Flow;Pulses/Unit;Units/Pulse |
0x333303B3 | dd_info_LABEL1 | Device Revision: %0\nDD Revision: %1 |
0x333303B4 | primary_purpose_vars_375_LABEL | Mass Flow Rate:\nValue %0 %1\n\nVolume Flow Rate:\nValue %2 %3\n\nDensity:\nValue %4 %5 |
0x333303B5 | primary_purpose_vars_gsv_375_LABEL | Mass Flow Rate:\nValue %0 %1\n\nGas Volume Flow Rate:\nValue %2 %3\n\nDensity:\nValue %4 %5 |
0x333303B6 | var_summary_temperature_LABEL | Temperature:\nValue %0 %1 |
0x333303B7 | var_summary_temperature_PM_LABEL | Temperature:\nValue %0 %1\n\nDensity at Reference Temperature:\nValue %2 %3\n\nAverage Observed Density:\nValue %4 %5 |
0x333303B8 | var_summary_PM_LABEL | Volume Flow at Ref Temp:\nValue %0 %1\n\nAverage Observed Temperature:\nValue %2 %3\n\nCTL:\nValue %4 |
0x333303B9 | var_summary_temperature_CM_LABEL | Temperature:\nValue %0 %1\n\nStd Vol Flow Rate:\nValue %2 %3\n\nStd Net Vol Flow Rate:\nValue %4 %5 |
0x333303BA | var_summary_CM_1_LABEL | Net Mass Flow Rate:\nValue %0 %1\n\nDensity at Ref:\nValue %2 %3\n\nConcentration:\nValue %4 %5 |
0x333303BB | var_summary_CM_2_LABEL | Density (Fixed SG Units) :\nValue %0 %1 |
0x333303BC | read_alarm_severity_alarm_number_LABEL | A%{alarmNum} is %{0} |
0x333303BD | totalizer_reset_option_LABEL | Not reset-able from display or digital communications;Reset-able from display only;Reset-able from digital communications only;Reset-able from display and digital communications |
0x333303C0 | menudisplay_next_LABEL | Next |
0x333303C1 | menudisplay_back_next_LABEL | Back;Next |
0x333303C2 | meth_view_alert_severity_options_LABEL | Individual Alert;All Alerts;None |
0x333303C3 | alarm_severity_choice_LABEL | Ignore;Information;Fault |
0x333303C7 | advanced_set_up_LABEL | Advanced Setup |
0x333303C8 | fourth_var_description_LABEL | The fourth variable is only used in HART communications. |
0x333303CA | str_enter_alarm_integer_LABEL | Enter Alert Number |
0x333303CB | grp_ack_all_LABEL | Acknowledge Alerts on Display |
0x333303CC | meth_view_alert_severity_of_LABEL | View Alert Severity of |
0x333303CD | alarm_integer_oor_LABEL | Alert Number invalid |
0x333303CE | percent_of_range_LABEL | Percent Range |
0x333303CF | a133_LABEL | A133: EEPROM Error (Display) |
0x333303D0 | alert_description_a133_LABEL | An uncorrectable checksum mismatch has been detected. |
0x333303D1 | recommended_action_a133_LABEL | Recommended Actions:\n1. Cycle power to the flow meter.\n2. The flow meter might need service. Contact Micro Motion. |
0x333303D2 | a113_LABEL | A113: mA Output 2 Saturated |
0x333303D3 | alert_description_a113_LABEL | The calculated amount of current output is outside of the linear range. |
0x333303D4 | recommended_action_a113_LABEL | Recommended Actions:\n1. Verify that mA output range values are set to appropriate values. |
0x333303D5 | a114_LABEL | A114: mA Output 2 Fixed |
0x333303D6 | alert_description_a114_LABEL | User has set the mA output to a fixed value. |
0x333303D7 | recommended_action_a114_LABEL | Recommended Actions:\n1. Exit mA output trim.\n2. Exit mA output loop test.\n3. Check to see if the output has been fixed via digital communications. |
0x333303DF | pressure_config_LABEL | Pressure Configuration |
0x333303E1 | mmi_diagnostics_variables_LABEL | Diagnostics Variables |
0x333303E2 | enter_alert_severity_LABEL | Enter Alert Severity |
0x333303F6 | freq_equals_flow_LABEL | Frequency=Flow |
0x333303F7 | vol_flow_type_LABEL | Volume Flow Type |
0x333303F8 | std_gas_vol_LABEL | Standard Gas Volume |
0x333303F9 | flow_switch_setpoint_LABEL | Setpoint |
0x333303FA | mmi_setup_milliamp_1_LABEL | Set Up mA Output 1 |
0x333303FB | mmi_setup_milliamp_2_LABEL | Set Up mA Output 2 |
0x33330401 | mmi_str_cal_zero_std_LABEL | Calibration in progress...\nZero: %{0}\nStandard Deviation: %{1} |
0x33330402 | mmi_str_zero_comp_LABEL | Auto zero complete.\nZero: %{0}\nStandard Deviation: %{1} |
0x33330418 | mmi_str_offset_cal_LABEL | Enter temperature in %{0} |
0x33330419 | mmi_str_temp_off_cal_comp_LABEL | Temperature offset calibration complete. |
0x3333041A | mmi_str_slope_cal_LABEL | Enter temperature in %{0} |
0x3333041B | mmi_str_temp_slop_cal_comp_LABEL | Temperature slope calibration complete. |
0x3333041C | backlight_control_new_LABEL | Control |
0x3333041F | sens_type_code_LABEL | Type |
0x33330420 | mmi_str_ao1_fixed_LABEL | Analog output 1 is fixed at %0 mA. |
0x33330421 | mmi_str_ao2_fixed_LABEL | Analog output 2 is fixed at %0 mA. |
0x33330426 | mmi_str_freq_level_LABEL | Choose Frequency Output Level |
0x33330427 | mmi_str_out_level_LABEL | Output Value |
0x33330428 | special_LABEL | Special |
0x3333042E | freq_output_fault_parameter_note_LABEL | Note: For frequency output fault action as upscale,set frequency output fault level value. |
0x3333042F | perform_action_code_LABEL | Action code was performed. |
0x33330430 | mA_output_settings_LABEL | mA Output Settings |
0x33330431 | reading_device_status_LABEL | Reading Device Status |
0x33330432 | ao_cutoff_LABEL | AO Cutoff |
0x3333043A | str_set_FO_LABEL | Set Frequency Output |
0x3333043E | OPLabel_new_LABEL | Select Output Behavior: |
0x3333043F | refresh_alerts_LABEL | Refresh Alerts |
0x33330442 | mmi_select_MVMode | Continue Measuring;Outputs Held at Last Value;Outputs Held at Fault |
0x33330444 | str_MV_in_progress | Meter verification in progress: %{0}% complete |
0x33330448 | reset_all_totals_dummy_LABEL | Reset All Totals |
0x3333046B | mmi_str_abort_error_LABEL | Aborting due to field device error. |
0x3333046C | mmi_str_freq_fixed_LABEL | Frequency output is fixed at %0 Hz. |
0x33330470 | mmi_str_prob_detected_LABEL | A problem was detected. |
0x33330471 | mmi_str_zero_fail_LABEL | Auto Zero Failed. |
0x33330472 | mmi_trim_description_1_LABEL | Perform digital to analog trim of the first milliamp output. |
0x33330473 | mmi_trim_description_2_LABEL | Perform digital to analog trim of the second milliamp output. |
0x33330474 | mmi_str_anal_2_level_LABEL | Choose Analog Output 2 Level |
0x33330476 | hysteresis_LABEL | Hysteresis (0.1-10.0) |
0x33330477 | hysteresis_help_LABEL | If the hysteresis is set to 5%, no change of the Discrete Output state occurs when the flow rate is within +-5% of the setpoint. If the setpoint is 100 lb/min and the first reading is below 95 lb/min, the flow switch turns On and will stay On until the flow rate rises above 105 lb/min. At this point it turns Off, and will stay off until the flow rate drops below 95 lb/min. |
0x3333047A | fcf_run_number_LABEL | Meter Verification Run Counter |
0x3333047B | fcf_time_LABEL | Transmitter Running Hours at Test |
0x3333047C | fcf_lpo_norm_LABEL | Left Pickoff Stiffness |
0x3333047D | fcf_rpo_norm_LABEL | Right Pickoff Stiffness |
0x3333047F | FRF_MV_FirstRun_Time_LABEL | Hours Until Next Run |
0x33330480 | FRF_MV_Recur_Time_LABEL | Hours Between Recurring Runs (0=Schedule is not Repeating) |
0x3333048A | transmitter_firmware_checksum_LABEL | Transmitter |
0x33330495 | show_results_table_LABEL | Show Results Table |
0x33330496 | run_number_LABEL | Run Number |
0x33330497 | test_result_LABEL | Test Result |
0x33330498 | abort_code_LABEL | Abort Code |
0x33330499 | norm_lpo_LABEL | Normalized LPO |
0x3333049A | norm_rpo_LABEL | Normalized RPO |
0x333304A6 | ma_output_1_cutoff_LABEL | MAO1 Cutoff |
0x333304A7 | ma_output_2_cutoff_LABEL | MAO2 Cutoff |
0x333304A8 | fourth_variable_code_qv_LABEL | QV |
0x333304AB | fcf_run_number_help_LABEL | The run counter for this Meter Verification run. |
0x333304AC | fcf_time_help_LABEL | The transmitter's power on time at the time of the test. |
0x333304AD | fcf_lpo_norm_help_LABEL | The left pickoff stiffness normalized to the baseline. |
0x333304AE | fcf_rpo_norm_help_LABEL | The right pickoff stiffness normalized to the baseline. |
0x333304AF | FRF_MV_FirstRun_Time_help_LABEL | The number hours until the next time meter verification runs. |
0x333304B0 | FRF_MV_Recur_Time_help_LABEL | The number of hours between successive meter verification runs. Valid range is 1 to 1000 hours or 0 for no recurring schedule. |
0x333304B1 | trim_description_multiple_LABEL | Perform digital to analog trim of the milliamp outputs. |
0x333304B4 | first_milliamp_loop_description_LABEL | Set a fixed output value for the first milliamp output. |
0x333304B5 | second_milliamp_loop_description_LABEL | Set a fixed output value for the second milliamp output. |
0x333304B6 | firmware_checksum_LABEL | Firmware Checksum |
0x333304B7 | start_meter_verification_LABEL | Start Meter Verification |
0x333304B8 | FRF_MV_Time_Left_help_LABEL | The number of hours remaining until Meter Verification runs. |
0x333304B9 | MV_ABORT_CODES_enum_0_LABEL | |
0x333304BA | MV_ABORT_CODES_enum_1_LABEL | User Initiated Abort |
0x333304BB | MV_ABORT_CODES_enum_2_LABEL | Abort Code |
0x333304BC | MV_ABORT_CODES_enum_3_LABEL | Frequency Drift |
0x333304BD | MV_ABORT_CODES_enum_4_LABEL | Abort Code 4 |
0x333304BE | MV_ABORT_CODES_enum_5_LABEL | High Drive Gain |
0x333304BF | MV_ABORT_CODES_enum_6_LABEL | Abort Code 6 |
0x333304C0 | MV_ABORT_CODES_enum_7_LABEL | Abort Code 7 |
0x333304C1 | MV_ABORT_CODES_enum_8_LABEL | Unstable Flow |
0x333304C2 | MV_ABORT_CODES_enum_9_LABEL | Abort Code 9 |
0x333304C3 | MV_ABORT_CODES_enum_10_LABEL | Abort Code 10 |
0x333304C4 | MV_ABORT_CODES_enum_11_LABEL | Abort Code 11 |
0x333304C5 | MV_ABORT_CODES_enum_12_LABEL | Abort Code 12 |
0x333304C6 | MV_ABORT_CODES_enum_13_LABEL | No Air Reference |
0x333304C7 | MV_ABORT_CODES_enum_14_LABEL | No Water Reference |
0x333304C8 | MV_ABORT_CODES_enum_15_LABEL | Missing Configuration |
0x333304C9 | MV_RESULT_enum_0_LABEL | Pass |
0x333304CA | MV_RESULT_enum_1_LABEL | Aborted in State 1 |
0x333304CB | MV_RESULT_enum_2_LABEL | Aborted in State 3 |
0x333304CC | MV_RESULT_enum_3_LABEL | Aborted in State 4 |
0x333304CD | MV_RESULT_enum_4_LABEL | Aborted in State 5 |
0x333304CE | MV_RESULT_enum_5_LABEL | Aborted in State 6 |
0x333304CF | MV_RESULT_enum_6_LABEL | Aborted in State 10 |
0x333304D0 | MV_RESULT_enum_7_LABEL | Aborted in State 15 |
0x333304D1 | MV_RESULT_enum_8_LABEL | Fail |
0x333304D2 | fix_analog_output_1_LABEL | mA Output 1 Loop Test |
0x333304D4 | analog_output_1_level_LABEL | Choose Analog Output 1 Level |
0x333304DB | turn_off_schedule_LABEL | Turn Off Schedule |
0x333304DF | a034_LABEL | A034: Meter Verification Failed |
0x333304E0 | a035_LABEL | A035: Meter Verification Aborted |
0x333304E1 | alert_description_a013_LABEL | Mechanical zero: The resulting zero was greater than 3 microseconds. |
0x333304E2 | a032_for_CPrev_more_that36_LABEL | A032: Outputs Fixed During Meter Verification |
0x333304F0 | a131_for_CPrev_more_that36_LABEL | A131: Meter Verification in Progress |
0x333304F6 | alert_description_a110_new_LABEL | Process variable assigned to frequency output is outside configured scale limits. |
0x333304F8 | string_meter_ver_op_fix_at_fault_LABEL | Meter Verification will hold outputs at fault value for about 2 minutes.\nPress Next to Start or Cancel to End. |
0x333304F9 | meter_ver_failed_continue_measure_LABEL | Meter Verification FAILED.\nMeter may not meet factory specifications.\nRecommend running Meter Verification with outputs held at last measured value or fault. |
0x333304FA | meter_ver_aborted_LABEL | Meter Verification ABORTED.\nReason: %{0}\nRecommended Action: Wait for 15 seconds before starting Meter Verification again. |
0x333304FD | enter_pressure_unit_LABEL | Enter Pressure Unit |
0x33330507 | do_di_assignment_enum_216_LABEL | Meter Verification Fail |
0x33330508 | mass_flow_digital_value_LABEL | Flow Rate |
0x33330513 | analog_output_1_LABEL | MAO1 |
0x33330514 | analog_output_2_LABEL | MAO2 |
0x33330516 | discrete_output_2_assignment_LABEL | Assignment |
0x33330518 | discrete_output_2_state_LABEL | Discrete Output State 2 |
0x33330525 | a119_discrete_output_2_LABEL | A119: Discrete Output 2 Fixed |
0x33330528 | str_do_1_level_LABEL | Choose Discrete Output 1 Level |
0x33330532 | str_perform_cal_dencal_a_LABEL | You are about to perform a first point calibration. |
0x33330533 | str_perform_cal_dencal_b_LABEL | You are about to perform a second point calibration. |
0x33330534 | str_perform_cal_dencal_c_LABEL | You are about to perform a third point calibration. |
0x33330535 | str_perform_cal_dencal_d_LABEL | You are about to perform a fourth point calibration. |
0x33330537 | select_sensor_type_option_straight_LABEL | Current Sensor Type Selection is T-Series (Straight Tube)\nSelect Sensor Type: |
0x33330538 | select_sensor_type_option_curved_LABEL | Current Sensor Type Selection is Other (Curved Tube)\nSelect Sensor Type: |
Reference ID | Label | String |