0 |
Milliamp input error |
1 |
Data loss possible |
2 |
Pressure polling |
3 |
Visc: Poll as Primary |
4 |
Visc: Poll as Secondary |
5 |
Comp: Poll as Primary |
6 |
Comp: Poll as Secondary |
7 |
Visc: Use Analog Input |
8 |
Comp: Use Analog Input |
9 |
Visc: Modbus DNLD |
10 |
Comp: Modbus DNLD |
11 |
Fld dev tag |
12 |
A calibration constant generated during a flowing (3rd point) density calibration. |
13 |
|
14 |
K3 |
15 |
6.5f |
16 |
Pressure compensation factor applied to flow rate (% change per PSI). |
17 |
% per psi |
18 |
Flow factr |
19 |
9.8f |
20 |
Pressure compensation factor applied to density (g/Cucm change per PSI). |
21 |
g/Cucm per psi |
22 |
Dens factr |
23 |
10.7f |
24 |
Pressure at which flow calibration was performed. |
25 |
Flowcal pressure |
26 |
6.2f |
27 |
Used by the Analog Input, this is the pressure (from external pressure transmitter) which is indicated by the 4 mA signal. |
28 |
4 mA pressure |
29 |
Used by the Analog Input, this is the pressure (from external pressure transmitter) which is indicated by the 20 mA signal. |
30 |
20 mA pressure |
31 |
4 mA Pressure too low |
32 |
20 mA Pressure too low |
33 |
Zero Pres. Correction Pt. too low |
34 |
Pressure comp |
35 |
.1f |
36 |
.2f |
37 |
.3f |
38 |
.4f |
39 |
.5f |
40 |
The mass flow rate below which the frequency/pulse output indicates zero flow, and below which totalizers stop counting. |
41 |
4.2f |
42 |
Sec |
43 |
% |
44 |
Determines whether the Event is activated when it goes above (High) or below (Low) the setpoint. |
45 |
7d |
46 |
8.2f |
47 |
The number of cycles, in Hertz, that equal a proportional flow rate represented by the frequency/pulse output. |
48 |
Hz |
49 |
The flow rate that equals a set frequency if the frequency output represents mass or volume flow; or the mass or volume total that equals a set number of pulses if the frequency output represents mass or volume total. |
50 |
Pulses |
51 |
.6f |
52 |
The volume flow rate below which the frequency/pulse output indicates zero flow, and below which totalizers stop counting. |
53 |
10.4f |
54 |
Pressure |
55 |
Event 1 |
56 |
10.2f |
57 |
Event1 unit |
58 |
Event1 anlog valu |
59 |
Event1 % rnge |
60 |
Event1 URV |
61 |
Event1 LRV |
62 |
Event1 URL |
63 |
Event1 LRL |
64 |
Event1 min span |
65 |
Event 2 |
66 |
Event2 unit |
67 |
Event2 anlog valu |
68 |
Event2 % rnge |
69 |
Event2 URV |
70 |
Event2 LRV |
71 |
Event2 URL |
72 |
Event2 LRL |
73 |
Event2 min span |
74 |
Flange |
75 |
Configuration information identifying the flange material used with the sensor. Informational purposes only - does not affect flowmeter operation. |
76 |
Configuration information identifying any liner material used with the sensor. Informational purposes only - does not affect flowmeter operation. |
77 |
Halar |
78 |
Configuration information identifying the sensor model installed. Informational purposes only - does not affect flowmeter operation. |
79 |
Configuration information identifying the material of which the sensor is constructed. Informational purposes only - does not affect flowmeter operation. |
80 |
Base mass unit |
81 |
A standard engineering unit that serves as the mass component in a special unit. |
82 |
Base mass time |
83 |
A standard unit of time (seconds, minutes, hours, or days) that serves as the time component in a special unit. |
84 |
Mass flo conv factr |
85 |
A programmable multiplier for the base mass unit in a special unit. |
86 |
Mass flo text |
87 |
A 1 to 4 character description of a special unit of flow. |
88 |
Mass totl text |
89 |
A 1 to 4 character description of a special unit of mass, which is based on the special unit of flow to represent total. |
90 |
A control that enables the user to determine whether the frequency/pulse output and totalizers will indicate forward, reverse, or bi-directional flow. |
91 |
Slug high limit |
92 |
A programmable high limit on density, which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. |
93 |
g/Cucm |
94 |
5.4f |
95 |
Slug low limit |
96 |
A programmable low limit on density, which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. |
97 |
FlowCal |
98 |
A 10-character factor that describes the sensitivity of the sensor to mass flow. The first 6 characters are the flow rate, in grams/second, per microsecond of time shift between velocity signals from the sensor. The 2nd four characters are the flow temperature coefficient. |
99 |
PV AO cutoff |
100 |
The mass or volume flow rate below which a milliamp output representing flow indicates zero flow. |
101 |
SV AO cutoff |
102 |
Base vol unit |
103 |
A standard engineering unit that serves as the volume component in a special unit. |
104 |
Base vol time |
105 |
Vol flo conv factr |
106 |
A programmable multiplier for the base volume unit in a special unit. |
107 |
Vol flo text |
108 |
A 1 to 4 character description of a special unit of flow. |
109 |
Vol totl text |
110 |
A 1 to 4 character description of a special unit of volume, which is based on the special unit of flow to represent total. |
111 |
A value (in Hertz) that will be indicated on the frequency output for the purpose of a loop test. |
112 |
Allows the user to Reset, Stop, or Start all totalizers. NOTE - Inventory totals are NOT reset. |
113 |
14 characters describing the sensitivity of the sensor to density. |
114 |
Zero time |
115 |
The number of readings collected from the sensor during an Auto Zero operation. |
116 |
Cycles |
117 |
5d |
118 |
Converg. limit |
119 |
A unitless number that allows the user to reject the Auto Zero operation if the standard deviation is greater than 10 times the programmed convergence limit. A convergence limit of zero disables this feature. |
120 |
Max pulse width |
121 |
For the RFT9739, a programmable time period, in seconds, that defines the crossover frequency for the frequency output, where Crossover freq. = 1 / (2 x Pulse width). Below the crossover, the output has a constant ON state, and an OFF state that varies with frequency. |
122 |
5.3f |
123 |
Control output |
124 |
An output that produces 0 V ON and 15 OFF digital levels. The control output can represent faults, zero in progress, flow direction, event 1 or event 2. |
125 |
Event1 |
126 |
Event2 |
127 |
Temp cal factr |
128 |
A 14-character factor that describes the slope and offset of the linear output representing flow tube temperature. |
129 |
A value, in microseconds, representing the phase shift between velocity signals from the sensor when measuring zero flow. |
130 |
uSec |
131 |
5.2f |
132 |
Zero units |
133 |
Units for zero offset - always microseconds. |
134 |
1d |
135 |
Std dev |
136 |
A unitless value which characterizes the amount of deviation between readings during an Auto Zero operation. |
137 |
Fault indicator |
138 |
Downscale: An analog output goes to 0 or 2 mA, the frequency = 0 Hz. Upscale: Milliamp outputs = 22 mA, the frequency output = 15 kHz. Last measured value: Outputs = value measured immediately before before fault. Internal zero: Outputs tied to flow = zero flow. |
139 |
Slug duration |
140 |
A programmable time period, from 0.00 to 60.00 seconds, during which outputs representing flow hold their last measured value before indicating slug flow. |
141 |
A variable which represents how [differential] pressure is brought into the transmitter for the purpose of viscosity calculation or pressure compensation. |
142 |
Visc cal factr |
143 |
A 14-character factor consisting of a slope and offset (optional) used to adjust the measured viscosity. |
144 |
A tag used to identify a pressure transmitter being polled by the 9739 via a HART network. |
145 |
User-entered viscosity for the purpose of performing an on-line viscosity calibration. |
146 |
Visc trim point |
147 |
Ref temperature |
148 |
User-entered temperature for the purpose of performing an on-line temperature calibration. |
149 |
Dens A |
150 |
The density, in g/cc, of the air or other low-density fluid used during a 2-point density calibration. Dens A can represent: The Dens A (D1) value on an ELITE sensor, a value of 0.0000 g/cc for a D, DL, or DT sensor with a 14-character dens cal factor. |
151 |
Dens B |
152 |
The density, in g/cc, of the water or other high-density fluid used during a 2-point density calibration. Dens B can represent: The Dens B (D2) value on an ELITE sensor, a value of 1.0000 g/cc for a D, DL, or DT sensor with a 14-character dens cal factor. |
153 |
K1 |
154 |
The tube period, in microseconds, corresponding to a density equal to Dens A. |
155 |
K2 |
156 |
The tube period, in microseconds, corresponding to a density equal to Dens B. |
157 |
Temp coeff |
158 |
The percent change in the elasticity of the flow tubes around the bending axis per 100 degrees Celsius. |
159 |
Event num |
160 |
Event1 type |
161 |
High Alarm |
162 |
Low Alarm |
163 |
Event2 type |
164 |
Event1 setpoint |
165 |
For the Model RFT9739, a programmable flow rate, total, density, temperature, differential pressure, or viscosity at which an output set to represent event 1 or event 2 switches states. |
166 |
Event2 setpoint |
167 |
Event1 var |
168 |
Assigns flow rate, total, density, temperature, differential pressure, or viscosity to event 1 or event 2. |
169 |
Event2 var |
170 |
Pres freq |
171 |
The frequency, in Hertz, presently being indicated on the frequency output. |
172 |
6.1f |
173 |
3d |
174 |
FMU860 |
175 |
DT |
176 |
DVC |
177 |
FCX |
178 |
AS800 |
179 |
340T |
180 |
340C |
181 |
344 |
182 |
Siemens Micro K |
183 |
SITRANS L |
184 |
SIPAN PH |
185 |
SITRANS P |
186 |
75SMT |
187 |
UNIDELTA |
188 |
8320 |
189 |
SX5100 |
190 |
TSV175 |
191 |
DMU |
192 |
3780 |
193 |
BM70 |
194 |
4.1f |
195 |
Date- Gregorian calendar date, entered as mm/dd/yy, that is stored in the Field Device. This date can be used by the user in any way. There is no specific recommended use. |
196 |
No |
197 |
8u |
198 |
Temperature out of range |
199 |
Event 1 triggered |
200 |
Event 2 triggered |
201 |
QV is |
202 |
Please refer to manual for complete calibration instructions. |
203 |
WARN-Loop should be removed from automatic control |
204 |
Flow must be zero
Perform calibration? |
205 |
A problem was detected |
206 |
Abort;Fix and Retry |
207 |
NOTE-Loop may be returned to automatic control |
208 |
Calibration in Progress
Zero: %{0}
Std dev: %{1} |
209 |
Auto Zero Failed |
210 |
Auto Zero Complete
Zero: %{0}
Std dev: %{1} |
211 |
Perform Cal |
212 |
Enter Density |
213 |
Perform calibration? |
214 |
Calibration in Progress... |
215 |
Density Calibration Complete |
216 |
Mass Flow must be greater than %{minflow} g/s.
Perform calibration? |
217 |
Slope Calibration
Enter Visc in %{0} |
218 |
Viscosity Calibration Complete |
219 |
Offset Calibration
Enter Visc in %{0} |
220 |
Offset Calibration
Enter Temp in %{0} |
221 |
Temperature Offset Calibration Complete |
222 |
Slope Calibration
Enter Temp in %{0} |
223 |
Temperature Slope Calibration Complete |
224 |
Outputs a user-programmed frequency to the frequency output. |
225 |
Choose frequency output level |
226 |
10 kHz;Other;End |
227 |
Output |
228 |
Aborting due to field device error |
229 |
Frequency output is fixed at %0 Hz |
230 |
Fix Analog Out 1 |
231 |
Choose analog output level |
232 |
4 mA;20 mA;Other;End |
233 |
Output value: |
234 |
Analog Output 1 is fixed at %0 |
235 |
Fix Analog Out 2 |
236 |
Analog Output 2 is fixed at %0 |
237 |
Trim Analog Out 1 |
238 |
Connect reference meter |
239 |
About to set analog output 1 to %0 mA |
240 |
Enter meter value |
241 |
Is fld dev 4.00 mA output equal to reference meter? |
242 |
Yes;No |
243 |
Is fld dev 20.00 mA output equal to reference meter? |
244 |
Trim Analog Out 2 |
245 |
About to set analog output 2 to %0 mA |
246 |
Instructs transmitter to perform internal self test. |
247 |
Selftest complete |
248 |
No Device Problems seen during Selftest |
249 |
Start totalizer |
250 |
Enables the internal totalizers to begin counting. Also enables the frequency/pulse output to indicate flow. |
251 |
Stop totalizer |
252 |
Prevents the internal totalizers from counting. Disables the frequency/pulse output from indicating flow. |
253 |
WARN-Stopping totalizer disables frequency output |
254 |
Reset totalizer |
255 |
Resets internal totalizers. |
256 |
ERROR: Totalizer reset not allowed when flow is not zero. |
257 |
Status Alarm1 |
258 |
When set, indicates that Event 1 has reached its programmed setpoint. |
259 |
Ev1 Triggered: Yes |
260 |
Ev1 Triggered: No |
261 |
Status Alarm2 |
262 |
When set, indicates that Event 2 has reached its programmed setpoint. |
263 |
Ev2 Triggered: Yes |
264 |
Ev2 Triggered: No |
265 |
View status |
266 |
Reports any currently active device status information. |
267 |
Transmitter status complete |
268 |
Transmitter status OK |
269 |
Min mass flow |
270 |
Minimum flow rate (in g/s) required for a 3rd point density calibration. |
271 |
Min mass flow = %{yatemp} g/s |
272 |
Aborts Auto Zero operation and continues to use previous zero offset value. |
273 |
Exits fixed mode and returns the frequency output to its active state. |
274 |
Returning fld dev to original output |
275 |
NOTE-Send PV assignment before modifying range values. |
276 |
NOTE-Send SV assignment before modifying range values. |
277 |
NOTE-Send TV assignment before modifying frequency scaling. |
278 |
NOTE-Variables which use this as the units code will be in the previous units until this value is sent to the device |
279 |
View fld dev vars |
280 |
View output vars |
281 |
Test/Status |
282 |
Charize sensor |
283 |
Config outputs |
284 |
Config events |
285 |
View PV-Analog 1 |
286 |
View SV-Analog 2 |
287 |
View TV-Frequency |
288 |
View QV |
289 |
View event 1 |
290 |
View event 2 |
291 |
Auto zero |
292 |
Density cal |
293 |
Viscosity cal |
294 |
Temperature cal |
295 |
Density |
296 |
Viscosity |
297 |
Flow |
298 |
Temperature |
299 |
Viscosity/Pressure |
300 |
Analog output 1 |
301 |
Analog output 2 |
302 |
Frequency output |
303 |
Fault output |
304 |
Event2 |
305 |
Dens Pt 1 (Air) |
306 |
Dens Pt 2 (Water) |
307 |
Dens Pt 3 (Flow) |
308 |
Visc slope cal |
309 |
Visc offset cal |
310 |
Temp slope cal |
311 |
Temp offset cal |
312 |
Spcl mass units |
313 |
Spcl vol units |
314 |
Device info |
315 |
Fld dev vars |
316 |
Outputs |
317 |
Write variables |
318 |
Anlog 1 range vals |
319 |
Anlog 2 range vals |
320 |
Freq scaling |
321 |
AO cutoff |
322 |
QV |
323 |
Value |
324 |
Invalid cutoff type code |
325 |
WARN-Loop should be removed from automatic control |
326 |
NOTE-Loop may be returned to automatic control |
327 |
Calibration in Progress... |