0 |
Commissioning |
1 |
Increased safety |
2 |
Expert mode |
3 |
None |
4 |
CurrentOutput_ActInstance |
5 |
Trim |
6 |
Off |
7 |
4 mA |
8 |
20 mA |
9 |
Calculate |
10 |
Reset |
11 |
Failure mode (34) |
12 |
Select alarm condition for current output value |
13 |
(a) Min. |
14 |
(b) Max. |
15 |
(c) Last valid value |
16 |
(d) Actual value |
17 |
(e) Defined value |
18 |
Failure current (35) |
19 |
Enter current output value in alarm condition |
20 |
mA |
21 |
.2f |
22 |
Fixed current (33) |
23 |
Defines the fixed output current. |
24 |
4 mA value |
25 |
Enter 4 mA value |
26 |
.3f |
27 |
|
28 |
% |
29 |
%/min |
30 |
%/s |
31 |
° |
32 |
°C |
33 |
°C/s |
34 |
°F |
35 |
°F/s |
36 |
°R |
37 |
µs |
38 |
A |
39 |
cm |
40 |
cm/min |
41 |
cm³ |
42 |
d |
43 |
dB |
44 |
dB/mm |
45 |
dm³ |
46 |
ft |
47 |
ft/h |
48 |
ft/s |
49 |
ft³ |
50 |
ft-in-16 |
51 |
ft-in-8 |
52 |
h |
53 |
hl |
54 |
Hz |
55 |
impGal |
56 |
in |
57 |
in/min |
58 |
in/s |
59 |
K |
60 |
K/s |
61 |
kg |
62 |
ks |
63 |
l |
64 |
lb |
65 |
m |
66 |
m/h |
67 |
m/s |
68 |
m³ |
69 |
mm |
70 |
mm/s |
71 |
ms |
72 |
mV |
73 |
None |
74 |
pF |
75 |
ppm |
76 |
rad |
77 |
s |
78 |
t |
79 |
ton |
80 |
unknown |
81 |
UsGal |
82 |
V |
83 |
20 mA value |
84 |
Enter 20 mA value |
85 |
Assign curr. |
86 |
Select process variable for current output |
87 |
Level linearized |
88 |
Distance |
89 |
Electronic temp. |
90 |
Relat.echo ampl. |
91 |
Analog out. AD1 |
92 |
Analog out. AD2 |
93 |
Area incoupling |
94 |
Measur. curr. 1 |
95 |
Shows the current value of the current output which is currently measured |
96 |
Measur. curr. 2 |
97 |
Measuring mode |
98 |
Select measuring mode for output |
99 |
Standard |
100 |
Inverse |
101 |
Current span (32) |
102 |
Select current range for process value output and upper/lower level for alarm signal |
103 |
(a) 4...20 mA |
104 |
(b) 4...20 mA NAMUR |
105 |
(c) 4...20 mA US |
106 |
(d) Fixed current |
107 |
Status |
108 |
u |
109 |
Output curr. 1 |
110 |
Shows the actual calculated value of the output current |
111 |
Output curr. 2 |
112 |
Start-up mode |
113 |
Min. |
114 |
Max. |
115 |
Defined value |
116 |
Start-up current |
117 |
Curr.out.1 sim. (46) |
118 |
Switch the simulation of the current output on and off |
119 |
On |
120 |
Curr.out.2 sim. (46) |
121 |
Value curr.out1 |
122 |
Enter the current value for simulation |
123 |
Value curr.out2 |
124 |
Damping out. |
125 |
Set reaction time for output signal to fluctuations in the measured value |
126 |
.1f |
127 |
Trim value high |
128 |
Trim value low |
129 |
Turn down |
130 |
Alarm delay 1 (60) |
131 |
.0f |
132 |
Alarm delay 2 (60) |
133 |
Value |
134 |
.4f |
135 |
Calc. type 1 (64) |
136 |
(a) Off |
137 |
(b) Maximum |
138 |
(c) Minimum |
139 |
(d) Mean |
140 |
(e) Std. deviation |
141 |
(f) Diff.Max. - Min. |
142 |
(g) Slope |
143 |
Calc. type 2 (64) |
144 |
Check mode 1 (69) |
145 |
(b) Upper limit |
146 |
(c) Lower limit |
147 |
(d) In range |
148 |
(e) Out of range |
149 |
Check mode 2 (69) |
150 |
Stat. AD event1 (80) |
151 |
Failure (F) |
152 |
Mainten. req.(M) |
153 |
Funct. check (C) |
154 |
Out of spec. (S) |
155 |
No effect (N) |
156 |
Stat. AD event2 (80) |
157 |
Evt behaviour1 (81) |
158 |
Alarm |
159 |
Warning |
160 |
Logbook only |
161 |
Evt behaviour2 (81) |
162 |
Hysteresis 1 (70) |
163 |
.5f |
164 |
Hysteresis 2 (70) |
165 |
Assign signal 1 (74) |
166 |
Unfiltered dist. |
167 |
Sensor debug |
168 |
Measur. curr. |
169 |
Terminal volt. |
170 |
Assign signal 2 (74) |
171 |
Link AD1 to (75) |
172 |
Digital out AD1 |
173 |
Digital out AD2 |
174 |
Link AD2 to (75) |
175 |
Link. logic AD1 (76) |
176 |
AND |
177 |
OR |
178 |
Link. logic AD2 (76) |
179 |
Upper limit 1 (77) |
180 |
Upper limit 2 (77) |
181 |
Maximum value 1 |
182 |
Maximum value 2 |
183 |
Lower limit 1 (78) |
184 |
Lower limit 2 (78) |
185 |
Minimum value 1 |
186 |
Minimum value 2 |
187 |
PresentInstance 1 |
188 |
Reset min/max1 |
189 |
Reset max. |
190 |
Reset min. |
191 |
Reset min/max |
192 |
Reset min/max2 |
193 |
Sample time 1 (79) |
194 |
Sample time 2 (79) |
195 |
Calc. unit 1 |
196 |
Calc. unit 2 |
197 |
Display interval (36) |
198 |
Set time measured values are shown on display if display alternates between values |
199 |
Backlight |
200 |
Switch the local display backlight on and off |
201 |
Disable |
202 |
Enable |
203 |
Config. managem. (39) |
204 |
Select action for managing the device data in the display module |
205 |
(a) Cancel |
206 |
(b) Execute backup |
207 |
(c) Restore |
208 |
(d) Duplicate |
209 |
(e) Compare |
210 |
(f) Clear backup |
211 |
Backup state |
212 |
Backup in progr. |
213 |
Restore in progr |
214 |
Import in progr. |
215 |
Delete in progr. |
216 |
Comp. in progr. |
217 |
Contrast display |
218 |
Adjust local display contrast setting to ambient conditions (e.g. lighting or reading angle) |
219 |
Display damping |
220 |
Set display reaction time to fluctuations in the measured value |
221 |
Decimal places1 |
222 |
Select the number of decimal places for the display value |
223 |
x |
224 |
x.x |
225 |
x.xx |
226 |
x.xxx |
227 |
x.xxxx |
228 |
Decimal places2 |
229 |
Decimal places3 |
230 |
Decimal places4 |
231 |
Last backup |
232 |
Indicates when the last data backup was saved to the display module |
233 |
Header text (55) |
234 |
Enter display header text |
235 |
Value 1 display |
236 |
Select the measured value that is shown on the local display |
237 |
Curr.output 1 |
238 |
Curr.output 2 |
239 |
Abs. echo ampl. |
240 |
Value 2 display |
241 |
Value 3 display |
242 |
Value 4 display |
243 |
Is clone availab |
244 |
Is restore avail |
245 |
Language |
246 |
Set display language |
247 |
English |
248 |
German |
249 |
French |
250 |
Spanish |
251 |
Italian |
252 |
Dutch |
253 |
Portuguese |
254 |
Polish |
255 |
Russian |
256 |
Swedish |
257 |
Turkish |
258 |
Chinese |
259 |
Japanese |
260 |
Korean |
261 |
Arabic |
262 |
Indonesian |
263 |
Thai |
264 |
Vietnamese |
265 |
Czech |
266 |
Locking status |
267 |
Indicates the write protection with the highest priority that is currently active |
268 |
Hardware locked |
269 |
SIL locked |
270 |
Up-/download |
271 |
Cust.trans. act. |
272 |
Temp. locked |
273 |
WHG locked |
274 |
FDA locked |
275 |
Header (38) |
276 |
Select header contents on local display |
277 |
Device tag |
278 |
Free text |
279 |
Format display (1) |
280 |
Select how measured values are shown on the display |
281 |
(a) 1 value, max. |
282 |
(b) Bargr. + 1 value |
283 |
(c) 2 values |
284 |
(d) Val. large+2val. |
285 |
(e) 4 values |
286 |
Def. access code |
287 |
Define release code for write access to parameters |
288 |
Separator |
289 |
Select decimal separator for displaying numerical values |
290 |
. |
291 |
, |
292 |
Compar. result (40) |
293 |
Comparison between present device data and display backup |
294 |
Set. identical |
295 |
Set. not ident. |
296 |
No backup |
297 |
Backup corrupt |
298 |
Check not done |
299 |
Dataset incomp. |
300 |
Access stat.disp |
301 |
Indicates access authorization to parameters via local display |
302 |
Operator |
303 |
Maintenance |
304 |
Service |
305 |
Production |
306 |
Development |
307 |
Number format (37) |
308 |
Choose number format for the display |
309 |
Decimal |
310 |
ft-in-1/16'' |
311 |
BitResolution 1 |
312 |
Channel 1 |
313 |
CompressionStatus 1 |
314 |
Compression ok |
315 |
Comp.inefficient |
316 |
Buf too small |
317 |
Comp.W/R overr |
318 |
Compr. failed |
319 |
CompressionType 1 |
320 |
No curve compr. |
321 |
Std curve compr |
322 |
DataId 1 |
323 |
SM EnvCrv |
324 |
SM EnvWeightCrv |
325 |
SM rawEC |
326 |
SM mapping curve |
327 |
SM error doc |
328 |
SM ref. curve |
329 |
SM tank trace |
330 |
DataLength 1 |
331 |
DataPoints 1 |
332 |
DataStream 1 |
333 |
PackageOffset 1 |
334 |
SampleDataType 1 |
335 |
type float32 |
336 |
type float64 |
337 |
data type uint8 |
338 |
data type uint16 |
339 |
data type uint32 |
340 |
data type sint8 |
341 |
data type sint16 |
342 |
data type sint32 |
343 |
TransactionId 1 |
344 |
Read SM data |
345 |
Read map. vector |
346 |
Write map.vector |
347 |
Read ECdiag.data |
348 |
Read ref curve |
349 |
Read history log |
350 |
Read events |
351 |
Read trend curve |
352 |
End data transf. |
353 |
TriggerDataTransferred 1 |
354 |
TriggerPrepare 1 |
355 |
TriggerStatus 1 |
356 |
VersionInfo 1 |
357 |
XDecimation 1 |
358 |
XEngineeringUnit 1 |
359 |
XMax 1 |
360 |
XMin 1 |
361 |
YEngineeringUnit 1 |
362 |
Digit |
363 |
Burst command 1 |
364 |
Select the HART command that is sent to the HART master |
365 |
Primary var (PV) |
366 |
Current/%Range |
367 |
DynamicVariables |
368 |
DV with status |
369 |
Device variables |
370 |
Add.device stat |
371 |
Burst command 2 |
372 |
Burst command 3 |
373 |
Burst mode 1 |
374 |
Switch HART burst mode for burst message on |
375 |
Burst mode 2 |
376 |
Burst mode 3 |
377 |
Burst variable0 |
378 |
For HART command 9 and 33, assign a HART device variable or process variable to burst variable |
379 |
Not used |
380 |
Percent of range |
381 |
Second.var(SV) |
382 |
Tertiary var(TV) |
383 |
Quaterna.var(QV) |
384 |
Burst variable1 |
385 |
Burst variable2 |
386 |
Burst variable3 |
387 |
Burst variable4 |
388 |
For HART command 33, assign a HART device variable or process variable to burst variable |
389 |
Burst variable5 |
390 |
Burst variable6 |
391 |
Burst variable7 |
392 |
Max. upd. per. |
393 |
Enter the maximum time span between two burst responses of one burst message |
394 |
Min. upd. per. |
395 |
Enter the minimum time span between two burst responses of one burst message |
396 |
Trigger level |
397 |
Enter the burst trigger value that determines together with the option selected in 'Burst trigger mode' parameter the time of burst message |
398 |
Trigger mode |
399 |
Select the event that triggers the burst message |
400 |
Continuous |
401 |
Window |
402 |
Rising |
403 |
Falling |
404 |
On change |
405 |
HART date code |
406 |
HART descriptor |
407 |
Device ID |
408 |
Shows the device ID for identifying the device in a HART network |
409 |
#.8x |
410 |
Device type |
411 |
Shows the device type with which the measuring device is registered with the HART Communication Foundation |
412 |
#.4x |
413 |
Manufacturer ID |
414 |
Shows the manufacturer ID device is registered with the HART Communication Foundation |
415 |
Enter the name for the measuring point |
416 |
HART message |
417 |
No. of preambles |
418 |
Defines the number o preambles in the HART telegram |
419 |
HART address |
420 |
Assign PV |
421 |
Assign QV |
422 |
Device revision |
423 |
Shows the device revision with which the device is registered with the HART Communication Foundation |
424 |
#.2x |
425 |
HART revision |
426 |
Hardware rev. |
427 |
Software rev. |
428 |
Assign SV |
429 |
HART short tag |
430 |
Defines short tag for the measuring point. |
431 |
Assign TV |
432 |
CstEmptyValue 1 |
433 |
CstFullValue 1 |
434 |
Lineariz. type (94) |
435 |
(a) None |
436 |
(b) Linear |
437 |
(c) Table |
438 |
(d) Pyramid bottom |
439 |
(e) Conical bottom |
440 |
(f) Angled bottom |
441 |
(g) Horizontal cyl. |
442 |
(h) Sphere |
443 |
Unit lineariz. (57) |
444 |
Activate table |
445 |
Table mode |
446 |
Manual |
447 |
Semiautomatic |
448 |
Clear table |
449 |
Sort table |
450 |
Level (25) |
451 |
Customer value (26) |
452 |
Table number (24) |
453 |
Unit lineariz. (21) |
454 |
Diameter (6) |
455 |
Diameter of the cylindrical or spherical tank |
456 |
Empty calibr. (3) |
457 |
Distance process connection to min. level |
458 |
EmptyScale 1 |
459 |
Output echo lost (27) |
460 |
(a) Last valid value |
461 |
(b) Ramp echo lost |
462 |
(c) Value echo lost |
463 |
(d) Alarm |
464 |
Full calibr. (4) |
465 |
Span: max. level - min level |
466 |
FullScale 1 |
467 |
Distance offset |
468 |
Intermed. height (22) |
469 |
Height of the pyramid, conical or angled bottom |
470 |
Level correction (20) |
471 |
Level limit mode (158) |
472 |
(b) Low limit |
473 |
(c) High limit |
474 |
(d) Low + High Limit |
475 |
High limit (159) |
476 |
Low limit (160) |
477 |
Maximum value (23) |
478 |
Linearized value corresponding to a level of 100%. |
479 |
Value echo lost (51) |
480 |
Output mode |
481 |
Ullage |
482 |
Fct. Inp.1 Lvl |
483 |
Low (0%) |
484 |
High (100%) |
485 |
Hold Last Value |
486 |
Fixed Value |
487 |
Fct. Inp.2 Lvl |
488 |
Distance (49) |
489 |
Level linearized (93) |
490 |
Level (7) |
491 |
Currently measured level |
492 |
Max.drain.speed |
493 |
Max. fill. speed |
494 |
Time max. level |
495 |
Max. level value |
496 |
Time min. level |
497 |
Min. level value |
498 |
L max draining |
499 |
L max.fill speed |
500 |
Ramp echo lost (52) |
501 |
Drain/fill speed |
502 |
Level |
503 |
I drain/fill spd |
504 |
Interface |
505 |
Reset all |
506 |
Fct.In.1 Interf |
507 |
Fct.In.2 Interf |
508 |
Level (68) |
509 |
Assign meas.var. (45) |
510 |
Interf. lineariz |
511 |
Thickn.lineariz. |
512 |
Proc. var. value |
513 |
Result selfcheck |
514 |
Passed |
515 |
Failed |
516 |
Unknown |
517 |
Applicat. param. |
518 |
Changed |
519 |
Not changed |
520 |
ApplicationParameterChangedFlags 1 |
521 |
Assign HART var? |
522 |
No |
523 |
Yes |
524 |
Detection active |
525 |
Output build up |
526 |
Open |
527 |
Closed |
528 |
Blocking dist. |
529 |
Dead band in front of the process connection |
530 |
Status |
531 |
Deact. all sim.? |
532 |
Deac. Build up ? |
533 |
Deac. foam detec |
534 |
Deactivate Help. |
535 |
Backup display? |
536 |
Dis.dist. corr.? |
537 |
Please select |
538 |
Distance medium? |
539 |
2 values |
540 |
DummyInvisibleParam 1 |
541 |
Empty calibr. |
542 |
Detection active |
543 |
Output foam |
544 |
Full calibr. |
545 |
Go to Envel curv |
546 |
Select toolbar |
547 |
Result dev.check |
548 |
Rec. mapping? |
549 |
Res. write prot. |
550 |
Reset write protection code |
551 |
SensorSilParameterChanged 1 |
552 |
SilParameterChanged 1 |
553 |
Sloped tank bo.? |
554 |
tank/bin empty? |
555 |
Medium type? |
556 |
(a) Low DC (e.g.oil) |
557 |
(b) High DC (water) |
558 |
Access stat.tool |
559 |
Shows the access authorization to the parameters via the operating tool |
560 |
Simulation? |
561 |
Resource avail. |
562 |
Bootloader rev. |
563 |
Shows the bootloader revision of the module firmware |
564 |
Build no. softw. |
565 |
Shows the build number of the module firmware |
566 |
Shows the firmware revision of the module. |
567 |
Shows the hardware revision of the module |
568 |
Module ID |
569 |
Module name |
570 |
Shows the name of the module |
571 |
Serial number |
572 |
Shows the serial number of the module |
573 |
PulseFrequencyState_ActInstance |
574 |
Assign limit |
575 |
Assign diag. beh (54) |
576 |
Select diagnostic behavior for switch output |
577 |
(a) Alarm |
578 |
(b) Alarm or warning |
579 |
(c) Warning |
580 |
Invert outp.sig. |
581 |
Invert the output signal |
582 |
Failure mode (61) |
583 |
Define output behavior in alarm condition |
584 |
(a) Actual status |
585 |
(b) Open |
586 |
(c) Closed |
587 |
Switch out funct (50) |
588 |
Select function for switch output |
589 |
(b) On |
590 |
(c) Diag. behavior |
591 |
(d) Limit |
592 |
(e) Digital Output |
593 |
(f) Fl. direct.check |
594 |
Switch status |
595 |
Shows the current switch output status |
596 |
Switch sim. |
597 |
Switch the simulation of the switch output on and off |
598 |
Select the status of the status output for the simulation |
599 |
Switch-off delay (59) |
600 |
Define delay for the switch-off of status output |
601 |
Switch-off value (72) |
602 |
Enter measured value for the switch-off point |
603 |
Switch-on delay (48) |
604 |
Define delay for the switch-on of status output |
605 |
Switch-on value (73) |
606 |
Enter measured value for the switch-on point |
607 |
Assign status |
608 |
Tank bottom ampl |
609 |
Acknowl. alarm |
610 |
Max. integr.time |
611 |
Integration time |
612 |
Add. meas. range |
613 |
Add. env. points |
614 |
Diagn. echo lost |
615 |
Diag.safety dist |
616 |
Ampl. gate size |
617 |
Valid range |
618 |
Not ok |
619 |
Ok |
620 |
Invalid range |
621 |
Not defined |
622 |
Not done |
623 |
Start self check |
624 |
Ant.ext.diameter |
625 |
Antenna ext.len. |
626 |
Sensor type |
627 |
Horn |
628 |
Rod |
629 |
Cladded horn |
630 |
Special antenna |
631 |
Without antenna |
632 |
Wave guide ant. |
633 |
Parabolic |
634 |
Planar |
635 |
Coax metal. disc |
636 |
Bin type |
637 |
Buffer silo fast |
638 |
Bin/ Pile |
639 |
Crusher / belt |
640 |
Silo |
641 |
Workbench test |
642 |
BD evaluat. mode |
643 |
No measur. in BD |
644 |
Measure in BD |
645 |
Via multip. echo |
646 |
CalculatedEop 1 |
647 |
CalculatedLevel 1 |
648 |
Reference dist. |
649 |
GPC mode |
650 |
Without correct. |
651 |
External correct |
652 |
Const.GPC factor |
653 |
Ref. echo thresh |
654 |
Ref. echo window |
655 |
Debug index |
656 |
Debug short name |
657 |
Debug sub index |
658 |
Debug value |
659 |
DigitsAt0mVdB 1 |
660 |
DigitsPermVdB 1 |
661 |
Hysteresis |
662 |
Confirm distance (11) |
663 |
Right dist. not found? Delete and perform a manual mapping. |
664 |
(a) Manual map |
665 |
(b) Distance ok |
666 |
(c) Distance unknown |
667 |
(d) Dist. too small |
668 |
(e) Distance too big |
669 |
(f) Tank empty |
670 |
(g) Factory map |
671 |
Draining filter |
672 |
First echo fact. |
673 |
DynPosWindowDownView 1 |
674 |
DynPosWindowUpView 1 |
675 |
Asym. far down |
676 |
Asym. far up |
677 |
Asym. near down |
678 |
Asym. near up |
679 |
Asym. near dist. |
680 |
.f |
681 |
FEF threshold |
682 |
Echo l.win.right |
683 |
Echo l.win.left |
684 |
Delay echo lost (62) |
685 |
Jump del. echol. |
686 |
Env. smooth.mode |
687 |
Sym. smoothing |
688 |
Asym. smoothing |
689 |
ECS in down |
690 |
ECS out down |
691 |
Env. curve stat. |
692 |
ECS in up |
693 |
ECS out up |
694 |
Env. smoothing |
695 |
Tank/silo height (161) |
696 |
TB range |
697 |
End map. ampl. |
698 |
End of mapping |
699 |
Adjustable |
700 |
Last map value |
701 |
Eop distance |
702 |
FAC offset |
703 |
FAC window size |
704 |
FMC offset |
705 |
FMC window size |
706 |
IEC offset |
707 |
Max Value EWC |
708 |
Weigh.crv.select |
709 |
FAC not rising |
710 |
Ideal echo |
711 |
FMC rising |
712 |
Filling filter |
713 |
Distance (9) |
714 |
First echo mode |
715 |
Fix on weightcrv |
716 |
Dynamic FEF |
717 |
Fix on max |
718 |
Fix max behind |
719 |
Lower level area |
720 |
Fix factor EWC |
721 |
First echo fact. |
722 |
Found echoes |
723 |
Level and TB |
724 |
EOP |
725 |
EOP (TT) |
726 |
EOP (LN) |
727 |
Level and EOP |
728 |
Multip. echo(TT) |
729 |
Free field spec. |
730 |
Gas comp. factor |
731 |
System damping |
732 |
Blocking dist. (19) |
733 |
Start dev. check |
734 |
Installation ok |
735 |
Accuracy reduced |
736 |
Meas.capab. red. |
737 |
Last check time |
738 |
Near distance |
739 |
Check not OK |
740 |
Check OK |
741 |
Level signal |
742 |
IecFitParameterXL 1 |
743 |
Inactive length |
744 |
Delta integ.time |
745 |
In safety dist. |
746 |
Self holding |
747 |
Area incoupling (156) |
748 |
Jump delay count |
749 |
Last level chang |
750 |
Max drain liquid (167) |
751 |
Slow < 1cm /min |
752 |
Medium <10cm/min |
753 |
Standard <1m/min |
754 |
Fast < 2m /min |
755 |
Very fast > 2m/m |
756 |
No filter / test |
757 |
Max. fill liquid (165) |
758 |
Present mapping (58) |
759 |
Present end of mapping |
760 |
Map end Y |
761 |
Map. end point (29) |
762 |
New end point of mapping |
763 |
Map gap |
764 |
Map offset |
765 |
Map overlay time |
766 |
Record map (12) |
767 |
Record map |
768 |
Recalculate map |
769 |
Overlay map |
770 |
Factory map |
771 |
Delete part. map |
772 |
Record init map |
773 |
Stop overlay |
774 |
Delete map |
775 |
Map. start point |
776 |
Map window size |
777 |
Max track count |
778 |
Max.electr.temp. |
779 |
Time max.el.temp |
780 |
Operating mode |
781 |
Signal quality |
782 |
Strong |
783 |
Medium |
784 |
Weak |
785 |
No signal |
786 |
(Strong) |
787 |
(Medium) |
788 |
(Weak) |
789 |
Measurm. freq. |
790 |
Dead time |
791 |
Medium group |
792 |
Others |
793 |
Water based DC>4 |
794 |
Medium type |
795 |
Liquid |
796 |
Solid |
797 |
Microfactor |
798 |
Min.electr.temp. |
799 |
Time min.el.temp |
800 |
Mov.track recog. |
801 |
Multi. echo pos. |
802 |
Wind.size track. |
803 |
Pres. ref. dist. |
804 |
Pres.calibr.fact |
805 |
Present FEF |
806 |
Pres.microfactor |
807 |
HF module mode |
808 |
Liquid extended |
809 |
Liquid standard |
810 |
Liquid st. 6 Ghz |
811 |
Liquid narrow |
812 |
Solid standard |
813 |
Time ref. curve |
814 |
Ref. echo ampl. |
815 |
Ref.echoposition |
816 |
Save ref. curve |
817 |
Merge echo dist. |
818 |
Edge correction |
819 |
Merg.echo window |
820 |
Fine adjust.mode |
821 |
Parabolic fit |
822 |
Edge correction |
823 |
Gravity center |
824 |
Ratio |
825 |
Parab fit window |
826 |
Merging ratio |
827 |
Relat.echo ampl. (157) |
828 |
Res.min/max temp |
829 |
History reset |
830 |
Reset done |
831 |
Restart tracking |
832 |
Delete history |
833 |
Thre. ring. area |
834 |
Safety distance |
835 |
History learning |
836 |
Hist. learn.ctrl |
837 |
Digital outp. 1 |
838 |
Digital outp. 2 |
839 |
Digital outp. 3 |
840 |
Digital outp. 4 |
841 |
Sensor module |
842 |
SML |
843 |
SMU |
844 |
SMR6 |
845 |
SMR26L |
846 |
SMR26S |
847 |
Value sim. dist. |
848 |
Sim distance |
849 |
Max.drain solid (169) |
850 |
Very slow<0.5m/h |
851 |
Slow < 1m /h |
852 |
Standard < 2m /h |
853 |
Medium < 4m /h |
854 |
Fast < 8m /h |
855 |
Very fast >8m/h |
856 |
Max. fill. solid (168) |
857 |
Adv. conditions |
858 |
Foam >5cm/0,16ft |
859 |
Changing DC val. |
860 |
Many obstacles |
861 |
Small tanks |
862 |
Weak signal |
863 |
ECS window size |
864 |
Tank type |
865 |
Bypass / pipe |
866 |
Stilling well |
867 |
Open channel |
868 |
Sphere |
869 |
Storage vessel |
870 |
Vessel standard |
871 |
Vessel w. agitat |
872 |
Evaluation mode |
873 |
History off |
874 |
Short time hist. |
875 |
Long time hist. |
876 |
Used calculation |
877 |
Tank bottom |
878 |
TB (TT) |
879 |
EOP level eval. |
880 |
Automatic DC |
881 |
Fix DC |
882 |
Min. ampl. TBD |
883 |
Tracking mode |
884 |
Track highest |
885 |
Track direction |
886 |
Track first |
887 |
Tank trace state |
888 |
Not active |
889 |
EOP+Multiplecho |
890 |
Trace rel.count |
891 |
Tube diameter (14) |
892 |
Calc. DC value |
893 |
DC: Dielectric constant |
894 |
Medium property |
895 |
DC 1.4 ... 1.6 |
896 |
DC 1.6 ... 1.9 |
897 |
DC 1.9 ... 2.5 |
898 |
DC 2.5 ... 4 |
899 |
DC 4 ... 7 |
900 |
DC 7 ... 15 |
901 |
DC > 15 |
902 |
Velocity filter |
903 |
Ant. zero dist. |
904 |
Cable zero dist. |
905 |
Electr.zero dist |
906 |
Char.test string |
907 |
Confirm Charact. |
908 |
Conf.funct.test |
909 |
SIL confirmation |
910 |
SIL/WHG prepar. |
911 |
In progress |
912 |
Finished |
913 |
Max. drain speed |
914 |
Tank/silo height |
915 |
Max. fill. speed |
916 |
Tube diameter |
917 |
SIL status |
918 |
SIL seq. active |
919 |
Active |
920 |
Sim. correct |
921 |
Code incorrect |
922 |
Reenter code |
923 |
Abort sequence |
924 |
Appr. level 1? |
925 |
Appr. level 2? |
926 |
Appr. level 3? |
927 |
Appr. level 4? |
928 |
Appr. level 5? |
929 |
Appr. limit? |
930 |
Limit below? |
931 |
Test proc. X |
932 |
Tol.dev<+/-2% 1 |
933 |
Tol.dev<+/-2% 2 |
934 |
Tol.dev<+/-2% 3 |
935 |
Tol.dev<+/-2% 4 |
936 |
Tol.dev<+/-2% 5 |
937 |
Tol.dev<+/-2% |
938 |
Read outp.cur.1 |
939 |
Read outp.cur.2 |
940 |
Read outp.cur.3 |
941 |
Read outp.cur.4 |
942 |
Read outp.cur.5 |
943 |
Read outp.cur. |
944 |
Sel. SIL or WHG |
945 |
WHG |
946 |
SIL |
947 |
SIL/WHG |
948 |
Select test proc |
949 |
Test proc. A |
950 |
Test proc. B |
951 |
Test proc. C |
952 |
Test proc. D |
953 |
Setpoint 1 |
954 |
Setpoint 2 |
955 |
Setpoint 3 |
956 |
Setpoint 4 |
957 |
Setpoint 5 |
958 |
Setpoint |
959 |
Sim. level 1 |
960 |
Sim. level 2 |
961 |
Sim. level 3 |
962 |
Sim. level 4 |
963 |
Sim. level 5 |
964 |
Sim. level value |
965 |
Sim.lev.val bel. |
966 |
Distance (99) |
967 |
Present mapping |
968 |
PresentFirstEchoAnchor 1 |
969 |
PresentFirstEchoThreshold 1 |
970 |
Ent. access code |
971 |
Enter access code to disable write protection of parameters |
972 |
Customized |
973 |
Firmware version |
974 |
Shows the device firmware version installed |
975 |
Device name |
976 |
Shows the name of the transmitter |
977 |
Ext. order cd.1 |
978 |
Shows the 1st part of the extended order code |
979 |
Ext. order cd.2 |
980 |
Shows the 2nd part of the extended order code |
981 |
Ext. order cd.3 |
982 |
Shows the 3rd part of the extended order code |
983 |
Order code |
984 |
Shows the device order code |
985 |
Shows the serial number of the measuring device |
986 |
ENP version |
987 |
Shows the version of the electronic nameplate (ENP) |
988 |
FactoryDataValid 1 |
989 |
Fieldbus Type |
990 |
No Fieldbus |
991 |
HART |
992 |
Profibus PA |
993 |
FF H1 |
994 |
MODBUS |
995 |
Profibus DP |
996 |
FF HSE |
997 |
NoFieldb.&bootl |
998 |
HART & bootldr |
999 |
PROFI.PA&bootldr |
1000 |
FF H1 & bootldr |
1001 |
MODBUS & bootldr |
1002 |
PROFIB.DP&bootl. |
1003 |
FF HSE & bootldr |
1004 |
XML build no. |
1005 |
Languages supp. |
1006 |
Deutsch |
1007 |
(Ara) |
1008 |
(Chinese) |
1009 |
etina (Czech) |
1010 |
Nederlands |
1011 |
Français |
1012 |
Bahasa Indonesia |
1013 |
Italiano |
1014 |
(Japanese) |
1015 |
(Korean) |
1016 |
Polski |
1017 |
Portuguesa |
1018 |
(Ru) |
1019 |
Español |
1020 |
Svenska |
1021 |
(Thai) |
1022 |
Türkçe |
1023 |
ting Vit (Vit) |
1024 |
Activate SW opt. |
1025 |
CT act.-def.par. |
1026 |
Device reset |
1027 |
Reset the device configuration - either entirely or in part - to a defined state |
1028 |
Cancel |
1029 |
To SW-defaults |
1030 |
To bus defaults |
1031 |
To fact.defaults |
1032 |
To delivery set. |
1033 |
Of customer set. |
1034 |
To transd.def. |
1035 |
Restart device |
1036 |
Start fact. def. |
1037 |
Start cust. set. |
1038 |
Start add fact. |
1039 |
Start add Cust. |
1040 |
Stop |
1041 |
Set write prot. |
1042 |
SW option overv. |
1043 |
Extend. HistoROM |
1044 |
HBT Verification |
1045 |
HBT Monitoring |
1046 |
Terminal volt.1 |
1047 |
Shows the current terminal voltage that is applied at the output |
1048 |
Clear event list |
1049 |
Delete all entries of the event list |
1050 |
Clear data |
1051 |
Status signal |
1052 |
OK |
1053 |
Offline |
1054 |
Actual diagnos. |
1055 |
-------- |
1056 |
C431 Trim 1 |
1057 |
C431 Trim 2 |
1058 |
C491 Current output 1 simulation |
1059 |
C491 Current output 2 simulation |
1060 |
F270 Main electronic failure |
1061 |
S921 Change of reference |
1062 |
I1089 Power on |
1063 |
I1090 Configuration reset |
1064 |
I1091 Configuration changed |
1065 |
I1092 HistoROM backup deleted |
1066 |
F942 In safety distance |
1067 |
942 In safety distance |
1068 |
M942 In safety distance |
1069 |
C942 In safety distance |
1070 |
S942 In safety distance |
1071 |
S943 In blocking distance |
1072 |
F437 Configuration incompatible |
1073 |
S801 Energy too low |
1074 |
F282 Data storage |
1075 |
F242 Software incompatible |
1076 |
C411 Up-/download active |
1077 |
M438 Dataset |
1078 |
F252 Modules incompatible |
1079 |
I1110 Write protection switch changed |
1080 |
C485 Simulation measured value |
1081 |
F435 Linearization |
1082 |
F941 Echo lost |
1083 |
941 Echo lost |
1084 |
M941 Echo lost |
1085 |
C941 Echo lost |
1086 |
S941 Echo lost |
1087 |
F272 Main electronic failure |
1088 |
F275 I/O module defective |
1089 |
F276 I/O module faulty |
1090 |
F271 Main electronic failure |
1091 |
F262 Module connection |
1092 |
F276 I/O module faulty |
1093 |
S825 Operating temperature |
1094 |
F825 Operating temperature |
1095 |
I1137 Electronic changed |
1096 |
F410 Data transfer |
1097 |
C494 Switch output simulation |
1098 |
C484 Failure mode simulation |
1099 |
F261 Electronic modules |
1100 |
I1151 History reset |
1101 |
S441 Current output 1 |
1102 |
S441 Current output 2 |
1103 |
I1154 Reset terminal voltage min/max |
1104 |
I1155 Reset electronic temperature |
1105 |
I1156 Memory error trend |
1106 |
I1157 Memory error event list |
1107 |
F283 Memory content |
1108 |
F803 Current loop |
1109 |
I1184 Display connected |
1110 |
I1185 Display backup done |
1111 |
I1186 Restore via display done |
1112 |
I1187 Settings downloaded with display |
1113 |
I1188 Display data cleared |
1114 |
I1189 Backup compared |
1115 |
C585 Simulation distance |
1116 |
M311 Electronic failure |
1117 |
F273 Main electronic failure |
1118 |
I1256 Display: access status changed |
1119 |
I1264 Safety sequence aborted |
1120 |
I1335 Firmware changed |
1121 |
C495 Diagnostic event simulation |
1122 |
C586 Record map |
1123 |
F950 Advanced diagnostic 1 occured |
1124 |
950 Advanced diagnostic 1 occured |
1125 |
M950 Advanced diagnostic 1 occured |
1126 |
C950 Advanced diagnostic 1 occured |
1127 |
S950 Advanced diagnostic 1 occured |
1128 |
F950 Advanced diagnostic 2 occured |
1129 |
950 Advanced diagnostic 2 occured |
1130 |
M950 Advanced diagnostic 2 occured |
1131 |
C950 Advanced diagnostic 2 occured |
1132 |
S950 Advanced diagnostic 2 occured |
1133 |
I1397 Fieldbus: access status changed |
1134 |
I1398 CDI: access status changed |
1135 |
I1512 Download started |
1136 |
I1513 Download finished |
1137 |
I1514 Upload started |
1138 |
I1515 Upload finished |
1139 |
C412 Processing download |
1140 |
I1554 Safety sequence started |
1141 |
I1555 Safety sequence confirmed |
1142 |
I1556 Safety mode off |
1143 |
Timestamp |
1144 |
Displays the timestamp for the currently active diagnostic message. |
1145 |
Event category1 |
1146 |
Timestamp of the diagnostic message. |
1147 |
Event category2 |
1148 |
Event category3 |
1149 |
Event category4 |
1150 |
Event category5 |
1151 |
Diagnostics 1 |
1152 |
Displays the currently active diagnostic message with the highest priority. |
1153 |
Diagnostics 2 |
1154 |
Displays the currently active diagnostic message with the second highest priority. |
1155 |
Diagnostics 3 |
1156 |
Shows the currently active diagnostic message with the third highest priority. |
1157 |
Diagnostics 4 |
1158 |
Shows the currently active diagnostic message with the fourth highest priority. |
1159 |
Diagnostics 5 |
1160 |
Shows the currently active diagnostic message with the fifth-highest priority. |
1161 |
Update Event |
1162 |
Prepare state |
1163 |
Filter options |
1164 |
Define which category of event messages is shown in the Events list submenu |
1165 |
All |
1166 |
Out of spec. (S) |
1167 |
Information (I) |
1168 |
PE_method_read_event |
1169 |
Entries list |
1170 |
Operating time |
1171 |
Indicates how long the device has been in operation |
1172 |
Time fr. restart |
1173 |
Prev.diagnostics |
1174 |
Shows the timestamp of the previous diagnostic message |
1175 |
Diag. event sim. |
1176 |
Select a diagnostic event to simulate this event |
1177 |
242 Software incompatible |
1178 |
252 Modules incompatible |
1179 |
261 Electronic modules |
1180 |
262 Module connection |
1181 |
270 Main electronic failure |
1182 |
271 Main electronic failure |
1183 |
272 Main electronic failure |
1184 |
273 Main electronic failure |
1185 |
275 I/O module defective |
1186 |
276 I/O module faulty |
1187 |
282 Data storage |
1188 |
283 Memory content |
1189 |
311 Electronic failure |
1190 |
410 Data transfer |
1191 |
411 Up-/download active |
1192 |
412 Processing download |
1193 |
431 Trim 1 |
1194 |
431 Trim 2 |
1195 |
435 Linearization |
1196 |
437 Configuration incompatible |
1197 |
438 Dataset |
1198 |
441 Current output 1 |
1199 |
441 Current output 2 |
1200 |
484 Failure mode simulation |
1201 |
485 Simulation measured value |
1202 |
491 Current output 1 simulation |
1203 |
491 Current output 2 simulation |
1204 |
494 Switch output simulation |
1205 |
585 Simulation distance |
1206 |
586 Record map |
1207 |
801 Energy too low |
1208 |
803 Current loop |
1209 |
825 Operating temperature |
1210 |
921 Change of reference |
1211 |
943 In blocking distance |
1212 |
Dev. alarm sim. |
1213 |
Switch the device alarm on and off |
1214 |
CustomVolumeOffset 1 |
1215 |
CustomVolumeScale 1 |
1216 |
Dec. places menu |
1217 |
Distance unit (2) |
1218 |
Length unit for distance calculation |
1219 |
Level unit (18) |
1220 |
Temperature unit |
1221 |
Select temperature unit |
1222 |
Read trend curv. |
1223 |
Read trend ch.1 |
1224 |
Read trend ch.2 |
1225 |
Read trend ch.3 |
1226 |
Read trend ch.4 |
1227 |
Assign chan. 1 (41) |
1228 |
Assign a process variable to logging channel |
1229 |
Assign chan. 2 (42) |
1230 |
Assign chan. 3 (43) |
1231 |
Assign chan. 4 (44) |
1232 |
MaxTrendEntries 1 |
1233 |
OperationHours 1 |
1234 |
Clear logging |
1235 |
Clear the entire logging data |
1236 |
Logging interval |
1237 |
Define the logging interval tlog for data logging. This value defines the time interval between the individual data points in the memory |
1238 |
TrendListStatus 1 |
1239 |
TrendNextListPosition 1 |
1240 |
TrendPackageSize 1 |
1241 |
Trend time |
1242 |
TrendSupportedPackageSize 1 |
1243 |
Read numb.val. |
1244 |
Version 1 |
1245 |
Remedy info. |
1246 |
Act.remedy info. |
1247 |
Remedy info. 1 |
1248 |
Remedy info. 2 |
1249 |
Remedy info. 3 |
1250 |
Remedy info. 4 |
1251 |
Remedy info. 5 |
1252 |
Pre.remedy info. |
1253 |
Edit: Assign signal 1 (74) |
1254 |
Edit: Assign signal 2 (74) |
1255 |
Edit: Reset min/max1 |
1256 |
Edit: Reset min/max2 |
1257 |
Edit: Config. managem. (39) |
1258 |
Edit: Reset min/max |
1259 |
Edit: Activate table |
1260 |
Edit: Medium type |
1261 |
Edit: Confirm distance (11) |
1262 |
Edit: History reset |
1263 |
Edit: Record map (12) |
1264 |
Edit: Start dev. check |
1265 |
Edit: Debug index |
1266 |
Edit: Debug sub index |
1267 |
Edit: Start self check |
1268 |
Edit: Res.min/max temp |
1269 |
Edit: Tank type |
1270 |
Edit: Bin type |
1271 |
Edit: Adv. conditions |
1272 |
Edit: Commissioning |
1273 |
Edit: Code incorrect |
1274 |
Edit: Set write prot. |
1275 |
Edit: Clear event list |
1276 |
Edit: Clear logging |
1277 |
Local_DeactivateFoamDetection_1 |
1278 |
SILProof_SimulationLevel3_1 |
1279 |
SILProof_SimulationLevelValueAbove_1 |
1280 |
Local_ResetWriteProtection_1 |
1281 |
SILProof_ReadOutputCurrentD_1 |
1282 |
SILProof_ReadOutputCurrentBelow_1 |
1283 |
SILProof_SimulationLevel4_1 |
1284 |
SILProof_ReadOutputCurrent1_1 |
1285 |
SPV_CurrentEventCategorySeparated_1 |
1286 |
SILProof_SimulationLevel5_1 |
1287 |
SILProof_ReadOutputCurrent2_1 |
1288 |
SB_FilteredDistance_1 |
1289 |
SB_ICInstallationCheckResult_1 |
1290 |
SILProof_ReadOutputCurrent3_1 |
1291 |
SILProof_ReadOutputCurrent4_1 |
1292 |
SILProof_ApproachedLevel5_1_1 |
1293 |
SILProof_ReadOutputCurrent5_1 |
1294 |
CO_OutValue_1_1 |
1295 |
Local_RecordMapping_1 |
1296 |
SILProof_ApproachedLevel3_1_1 |
1297 |
SILProof_HelpParameterToResetSILWHGProof_1 |
1298 |
SILProof_ApproachedLevelLimitBelow_1 |
1299 |
SILProof_ApproachedLevel1_1_1 |
1300 |
SILProof_SimulationLevelValueBelow_1 |
1301 |
SILProof_ReadOutputCurrentAbove_1 |
1302 |
Local_FoamOutSignalInvert_1 |
1303 |
SILProof_ApproachedLevel4_1_1 |
1304 |
Local_BuildUpOutSignalInvert_1 |
1305 |
Local_DeactivateBuildUpDetection_1 |
1306 |
DIAG_InputSelectorAnalogInput_2_1 |
1307 |
DIAG_InputSelectorAnalogInput_2_2 |
1308 |
SB_AnalogPathTestResult_1 |
1309 |
SILProof_SimulationLevel1_1 |
1310 |
SILProof_ApproachedLevel2_1_1 |
1311 |
SILProof_ApproachedLevelLimitAbove_1 |
1312 |
SILProof_SimulationLevel2_1 |
1313 |
Response_Code_msg |
1314 |
BCT_request |
1315 |
Blocktransfer DWORD(4)_1 |
1316 |
Blocktransfer DWORD(4)_2 |
1317 |
Blocktransfer DWORD(4)_3 |
1318 |
Blocktransfer DWORD(4)_4 |
1319 |
Blocktransfer DWORD(4)_5 |
1320 |
Blocktransfer DWORD(4)_6 |
1321 |
Blocktransfer DWORD(4)_7 |
1322 |
Blocktransfer DWORD(4)_8 |
1323 |
Blocktransfer DWORD(4)_9 |
1324 |
Blocktransfer DWORD(4)_10 |
1325 |
Blocktransfer DWORD(4)_11 |
1326 |
Blocktransfer DWORD(4)_12 |
1327 |
Blocktransfer DWORD(4)_13 |
1328 |
Blocktransfer DWORD(4)_14 |
1329 |
Blocktransfer DWORD(4)_15 |
1330 |
Blocktransfer DWORD(4)_16 |
1331 |
Blocktransfer DWORD(4)_17 |
1332 |
Blocktransfer DWORD(4)_18 |
1333 |
Blocktransfer DWORD(4)_19 |
1334 |
Blocktransfer DWORD(4)_20 |
1335 |
Blocktransfer DWORD(4)_21 |
1336 |
Blocktransfer DWORD(4)_22 |
1337 |
Blocktransfer DWORD(4)_23 |
1338 |
Blocktransfer DWORD(4)_24 |
1339 |
Blocktransfer DWORD(4)_25 |
1340 |
port |
1341 |
Sensor number |
1342 |
Sensor 1 |
1343 |
Sensor 2 |
1344 |
Curve ID |
1345 |
crvEcho |
1346 |
crvRawEcho |
1347 |
crvMap |
1348 |
crvWeighting |
1349 |
crvRef |
1350 |
Data transfer finished |
1351 |
X minimum value |
1352 |
X maximum value |
1353 |
X decimation value |
1354 |
Preparation status |
1355 |
x_eng_unit |
1356 |
Y engineering unit |
1357 |
UNITS_CODE(45) |
1358 |
Transmission length |
1359 |
Number of data points |
1360 |
Compression state |
1361 |
success |
1362 |
inefficient (nur geräteintern) |
1363 |
Dst2Small |
1364 |
WrIntoRd |
1365 |
Fail (schwerer interner Fehler) |
1366 |
Corrected Xmin |
1367 |
Device corrected starting point in engineering unit |
1368 |
Corrected Xmax |
1369 |
Device corrected ending point in engineering unit |
1370 |
function_code |
1371 |
Master Byte Count |
1372 |
Device Byte Count |
1373 |
Segment Length Changed |
1374 |
Port not Found |
1375 |
Port in Use |
1376 |
Maximum Ports In Use |
1377 |
Segment Length Too Small |
1378 |
Blocktransfer Float_1 |
1379 |
Blocktransfer Float_2 |
1380 |
Blocktransfer Float_3 |
1381 |
Blocktransfer Float_4 |
1382 |
Blocktransfer Float_5 |
1383 |
Blocktransfer Float_6 |
1384 |
Blocktransfer Float_7 |
1385 |
Blocktransfer Float_8 |
1386 |
Blocktransfer Float_9 |
1387 |
Blocktransfer Float_10 |
1388 |
Blocktransfer Float_11 |
1389 |
Blocktransfer Float_12 |
1390 |
Blocktransfer Float_13 |
1391 |
Blocktransfer Float_14 |
1392 |
Blocktransfer Float_15 |
1393 |
Blocktransfer Float_16 |
1394 |
number_bytes_message |
1395 |
Port not Open |
1396 |
Close port |
1397 |
End of transfer |
1398 |
Progress |
1399 |
countPoints |
1400 |
Point 1 X Value |
1401 |
Point 1 Y Value |
1402 |
1 |
1403 |
2 |
1404 |
3 |
1405 |
4 |
1406 |
5 |
1407 |
6 |
1408 |
7 |
1409 |
8 |
1410 |
9 |
1411 |
10 |
1412 |
11 |
1413 |
12 |
1414 |
13 |
1415 |
14 |
1416 |
15 |
1417 |
16 |
1418 |
17 |
1419 |
18 |
1420 |
19 |
1421 |
20 |
1422 |
21 |
1423 |
22 |
1424 |
23 |
1425 |
24 |
1426 |
25 |
1427 |
26 |
1428 |
27 |
1429 |
28 |
1430 |
29 |
1431 |
30 |
1432 |
31 |
1433 |
32 |
1434 |
Lineariz. graph. |
1435 |
X-value |
1436 |
Y-value |
1437 |
Edit table |
1438 |
Read table |
1439 |
Save table |
1440 |
Update values in the Linearization graph |
1441 |
Linearisation read failed |
1442 |
Linearisation write failed |
1443 |
Defines which current the output assumes in the case of an error.
Min.:
< 3.6mA
Max.:
> 21.95mA
Last valid value:
Last valid value before occurrence of the error.
Actual value:
Output current is equal to the measured value; error is ignored.
Defined value:
User defined value.
|
1444 |
Defines which current the output assumes in case of an error. |
1445 |
Define constant value of the output current. |
1446 |
Determines which process variable is transmitted via the current output. |
1447 |
Determines the current range used to transmit the measured value.
420mA:
Measured variable: 4 20 mA
420mA NAMUR:
Measured variable: 3.8 20.5 mA
420mA US:
Measured variable: 3.9 20.8 mA
Fixed current:
Measured variable transmitted via HART only
Note:
Currents below 3.6 mA or above 21.95 mA can be used to signal an alarm.
|
1448 |
On
The current simulation is active . The output current does not correspond to the measured value but to the value defined in the Value current output parameter.
Off
The current simulation is not active. The output current corresponds to the measured value. |
1449 |
Defines the value of the simulated output current. |
1450 |
Reaction time of the output signal on fluctuation in the measured value. |
1451 |
Resets the min or max drag indicator of the process variable which has been assigned to the Advanced Diganostic block via the 'Assign diagnostic signal' parameter. |
1452 |
This selection does not affect the measurement and calculation accuracy of the device. |
1453 |
Enter date of the last configuration change. Use this format yyyy-mm-dd |
1454 |
Enter a unique name for the measuring point to identify the device quickly within the plant. |
1455 |
First HART variable (Primary Variable) |
1456 |
Fourth HART variable (Quaternary Variable) |
1457 |
Second HART variable (Secondary Variable) |
1458 |
Defines the short tag for the measuring point.
Maximum length: 8 characters
Allowed characters: A-Z, 0-9, certain special characters |
1459 |
Third HART variable (Tertiary Variable) |
1460 |
Defines the editing mode of the linearization table.
'Manual'
The level and the associated linearized value are entered manually for each linearization point.
'Semiautomatic'
The level is measured by the device for each linearization point. The associated linearized value is entered manually.
'Clear table'
Deletes the existing linearization table.
'Sort table'
Rearranges the linerization points into an ascending order.
Note:
DeviceCare and FieldCare contain a graphical tool for the easy creation of a linearization table.
Device Care: 'Additional functions' -> 'Linearization table'
FieldCare: 'Device Operation' -> 'Device Functions' -> 'Additional functions' -> 'Linearization table' |
1461 |
Defines the unit of the linearized value.
Note:
The selected unit is only used to be indicated on the display. The measured value is not transformed according to the selected unit.
Note:
If 'Free text' is selected, an additional parameter 'Free text' appears in which the designation of the unit can be defined. |
1462 |
Distance between process connection and minimum level (0%). |
1463 |
Defines the behavior of the output in case of an echo loss.
'Last valid value'
Last valid value is kept.
'Ramp at echo lost'
Output value is continuously shifted towards 0% or 100%.
'Value echo lost'
Output assumes a defined value.
'Alarm'
Device generates an alarm.
|
1464 |
Distance between minimum level (0%) and maximum level (100%). |
1465 |
The measured level is corrected by this value to compensate for a constant level error.
Level correction > 0:
The level is increased by this value.
Level correction < 0:
The level is decreased by this value. |
1466 |
Determines whether the output value is limited by an upper or lower limit (or by both). |
1467 |
Defines the upper limit of the output value. |
1468 |
Defines the lower limit of the output value. |
1469 |
Value of the output in case of an echo loss. |
1470 |
Currently measured level |
1471 |
Slope of the ramp in the case of an echo loss.
Note:
If the slope is positive (+), the output increases until it reaches 100%.
If the slope is negative (-), the output decreases until it reaches 0%.
|
1472 |
Resets the drag indicator of the selected process variable. |
1473 |
Defines the process variable to be simulated. |
1474 |
Defines the value of the selected variable.
The outputs assume values or states according to this value. |
1475 |
Defines which process variable will be checked for limit violation. |
1476 |
Defines to which behavior of diagnostic events the switch output reacts. |
1477 |
'No'
The switch output behaves as per its parameter setting.
'Yes'
The switching behavior is inverted as compared to its parameter setting. |
1478 |
Defines the state of the switch output in case of an error. |
1479 |
Defines the function of the switch output.
'Off'
The switch output is always open (non-conductive)
'On'
The switch output is always closed (conductive).
'Diagnostic behavior'
The switch output is normally closed and is only opened if a diagnostic event is present.
'Limit'
The switch output is normally closed and is only opened if a measured variable exceeds a defined limit.
'Digital output'
The switch output is controlled by one of the digital output blocks of the device.
|
1480 |
Current status of the switch output. |
1481 |
On
The switch output simulation is active. The status of the switch output does not correspond to the state of the device (e.g. limit violation or alarm) but is directly defined in the Switch output status parameter.
Off
The switch output simulation is not active. The status of the switch output corresponds to the state of the device (e.g. limit violation or alarm). |
1482 |
Defines the delay applied before the output is switched off. |
1483 |
Defines the switch-off point.
The output is opened if the assigned process variable falls below this point. |
1484 |
Defines the delay applied before the output is switched on. |
1485 |
Defines the switch-on point.
The output is closed if the assigned process variable rises above this point. |
1486 |
Assigns a Discrete Output Block or an Advanced Diagnostic Block to the switch output. |
1487 |
A test signal is generated in the sensor module and fed into the analog path of the device.
Verification Test echo in the time window.
Verification of the test echo amplitude. |
1488 |
Optimizes the signal filters for the respective bin type.
Note:
'Workbench test' deactivates all filters. This option should exclusively be used for tests. |
1489 |
The value of the reference distance in the completely depressurized state. |
1490 |
Time between the echo loss and the reaction defined for the output.
|
1491 |
If the parametrized measuring range (Empty calibration) differs significantly from the tank or silo height, it is recommended to enter the tank or silo height in this parameter.
Example:
Continuous level monitoring in the upper third of a tank or silo.
Note:
For tanks with conical outlet, this parameter should not be changed as in this type of applications 'Empty calibration' is usually not << the tank or silo height. |
1492 |
Distance between lower edge of flange or thread and medium surface. |
1493 |
The area at the upper end of the probe in which no signals are evaluated, e.g. to suppress condensation or build-up.
Note:
The preset value depends on 'Empty calibration' and 'Full calibration'.
Note:
The measuring range should not overlap with the blocking distance. |
1494 |
The device has a function that detects and reports any interference by unfavorable installation situation. Here, the amplitudes of measured signals are monitored, which refer to interference in the near range. |
1495 |
By selecting the maximum expected filling and draining speed the signal evaluation is automatically optimized for the process.
Note:
The filling and draining speeds can be set separately as the filling and draining procedures may be different.
Note:
With the No filter / test option all signal evaluation filters are deactivated. This option should exclusively be used for tests. |
1496 |
By selecting the maximum expected filling and draining speed the signal evaluation is automatically optimized for the process.
Note:
The filling and draining speeds can be set separately as the filling and draining procedures may be different.
Note:
With the No filter / test option all signal evaluation filters are deactivated. This option should exclusively be used for tests. |
1497 |
Controls the recording of the map.
'No'
No map is recorded.
'Record map'
The map is recorded.
'Overlay map'
The new map is generated by overlaying the old map and the current envelope curve.
'Factory map'
The factory map permanently stored in the device is used.
'Delete partial map'
The map is deleted up to the defined 'Mapping end point'.
'Delete map'
The complete map (if one exists) is deleted. |
1498 |
The main criterion is the dielectric constant (DC) of the medium.
'Others (e.g. oil)'
Valid for DC < 4. Must also selected if two media is present. With this selection the total level will be measured (but not the interface height).
'Water based (DC >= 4)'
Valid for DC >= 4
Note:
Dielectric constants of many media are summarized in the DC compendium (see link below).
|
1499 |
Indicates the currently measured distance of the reference signal.
This value changes according to the pressure of the gas phase.
Note:
The reference signal is generated by the reference rod at the upper probe end.
|
1500 |
Saves the envelope curve of the setup to be used as a reference for diagnostic purposes later in the process.
Note:
The reference curve is stored in the device. |
1501 |
Resets the drag indicator of the electronics temperature. |
1502 |
By selecting the maximum expected filling and draining speed the signal evaluation is automatically optimized for the process.
Note:
The filling and draining speeds can be set separately as the filling and draining procedures may be different.
Note:
With the No filter / test option all signal evaluation filters are deactivated. This option should exclusively be used for tests. |
1503 |
Optimizes the signal filters for the respective tank type.
Note:
'Workbench test' deactivates all filters. This option should exclusively be used for tests. |
1504 |
Inner diameter of the stilling well or bypass pipe. |
1505 |
Select the diagnostic event to be simulated.
Note:
To terminate the simulation, select 'Off'. |
1506 |
Used for the basic calibration (Empty / Full). |
1507 |
Used to display the level. |
1508 |
Used to display the electronics temperature. |
1509 |
Up to four HART variables can be transmitted via the HART protocol.
At the same time they are indicated on the Dashboard (Homepage) of the device.
Select 'yes' to show/assign measuring variables to these HART variables. |
1510 |
'Yes' is marked if the build-up detection is currently active. |
1511 |
Determines how the presence of build-up is indicated by the switch output.
'Opened'
Build-up is indicated by the switch being opened.
'Closed'
Build-up is indicated by the switch being closed. |
1512 |
The area at the upper end of the probe in which no signals are evaluated, e.g. to suppress condensation or build-up.
Note:
The measuring range should not overlap with the blocking distance. |
1513 |
A simulation is currently active. Thus the output value does not correspond to the measured value. In order to terminate the simulation: Select 'Yes'. |
1514 |
Mark 'Yes' to deactivate the build-up detection. Parameters related to build-up detection are not changed.
If required, the build-up detection can be reactivated by going through this wizard again and confirming all parameter values. |
1515 |
Mark 'Yes' to deactivate the foam detection. Parameters related to foam detection are not changed.
If required, the foam detection can be reactivated by going through this wizard again and confirming all parameter values. |
1516 |
'Yes'
The map will be recorded from the process connection to the current level.
'No'
The actual distance must be specified manually.
Note:
For distances smaller than 1m (3.3ft) a mapping cannot be recorded. In this case the vessel must be drained. |
1517 |
Enter actual distance between lower end of flange or thread and medium surface.
The mapping will be recorded up to this distance. |
1518 |
'Yes' is marked if the foam detection is currently active. |
1519 |
Determines how the presence of foam is indicated by the switch output.
'Opened'
Foam is indicated by the switch being opened.
'Closed'
Foam is indicated by the switch being closed. |
1520 |
Ideally the mapping should be recorded while the tank is empty.
If this is not possible, a preliminary mapping can be recorded with the tank partially filled.
For optimization it is recommended to record the mapping again when the tank is empty.
Note:
If an agitator is present, make sure that it is rotating while the map is recorded.
|
1521 |
Enter SIL or WHG locking code in order to unlock the device. |
1522 |
Specify where the radar beam hits the tank bottom.
No:
The radar beam hits the flat part of the tank bottom.
Yes:
The radar beam hits the sloped part of the tank bottom. |
1523 |
Selection 'yes' will carry out a mapping over the whole measuring range. |
1524 |
The main criterion is the dielectric constant (DC) of the medium.
'Low DC (e.g. oil)'
Valid for DC < 4
'High DC (water based)'
Valid for DC >= 4
Note:
Dielectric constants of many media are summarized in the DC compendium (see link below).
|
1525 |
The simulation can be used to check the configuration of the device and of connected evaluation units. |
1526 |
Approach the level to be tested. Then select 'Yes'.
|
1527 |
Approach a level slightly above the switching point. Then select 'Yes'. |
1528 |
Approach a level slightly below the switching point. Then select 'Yes'. |
1529 |
Checks whether the calculated and measured current coincide within the required accuracy.
The result is indicated as 'Passed' or 'Failed'. |
1530 |
Measure the output current in the signal line and enter the value into this parameter.
Note:
The minimum accuracy of the multimeter should be ±0.1 mA. |
1531 |
Shows the expected value of the output current. |
1532 |
Enter the level to be checked.
The output current will assume a value corresponding to this level. |
1533 |
Enter a level slightly above the switching point.
The output current will assume a value corresponding to this level. |
1534 |
Enter a level slightly below the switching point.
The output current will assume a value corresponding to this level. |
1535 |
Device info |
1536 |
maintenance_root_menu |
1537 |
Feature not supported |
1538 |
offline_root_menu |
1539 |
Device Diagnostics |
1540 |
Administration |
1541 |
Adv.diagn. 1 |
1542 |
Adv.diagn. 2 |
1543 |
Advanced setup |
1544 |
Communication |
1545 |
Conf.backup disp |
1546 |
Debug |
1547 |
Device check |
1548 |
Diagnostic list |
1549 |
Diagnostics |
1550 |
Display |
1551 |
Echo adjust.fine |
1552 |
Echo tracking |
1553 |
Env. curve |
1554 |
Envelope diag. |
1555 |
Event logbook |
1556 |
Expert |
1557 |
Gas phase comp. |
1558 |
Burst config. 1 |
1559 |
Burst config. 2 |
1560 |
Burst config. 3 |
1561 |
Configuration |
1562 |
Information |
1563 |
Output |
1564 |
Linearization |
1565 |
Mapping |
1566 |
Medium |
1567 |
Min/max val. |
1568 |
Display module |
1569 |
FT module |
1570 |
I/O module |
1571 |
Mainboard module |
1572 |
Sensor module |
1573 |
Process variab. |
1574 |
Switch output |
1575 |
Safety sett. |
1576 |
Sensor diag. |
1577 |
Sensor prop. |
1578 |
Sensor |
1579 |
Setup |
1580 |
Simulation |
1581 |
System |
1582 |
Tank bottom eval |
1583 |
Data logging |
1584 |
Weighting curves |
1585 |
Basic setup |
1586 |
Adv.diagn. 1-1 |
1587 |
Adv.diagn. 2-1 |
1588 |
Adv.diagn. 1-2 |
1589 |
Adv.diagn. 2-2 |
1590 |
Adv.diagn. 1-3 |
1591 |
Adv.diagn. 2-3 |
1592 |
Adv.diagn. 1-4 |
1593 |
Adv.diagn. 2-4 |
1594 |
Curr.output 1-1 |
1595 |
Curr.output 1-2 |
1596 |
Curr.output 1-3 |
1597 |
Curr.output 2-1 |
1598 |
Curr.output 2-2 |
1599 |
Ext. order cd. |
1600 |
Display 1 |
1601 |
Display 2 |
1602 |
Distance 1 |
1603 |
Distance 2 |
1604 |
Distance 3 |
1605 |
Env. curve 1 |
1606 |
Env. curve 2 |
1607 |
Burst config. |
1608 |
Burst message 1 |
1609 |
Burst message 2 |
1610 |
Burst message 3 |
1611 |
HART info |
1612 |
HART output |
1613 |
Information 1 |
1614 |
Information 2 |
1615 |
Level 1 |
1616 |
Level 2 |
1617 |
Level 3 |
1618 |
Mapping 1 |
1619 |
Mapping 2 |
1620 |
Measured val. |
1621 |
Min/max val. 1 |
1622 |
Min/max val. 4 |
1623 |
Safety sett. 1 |
1624 |
Safety sett. 2 |
1625 |
Sensor diag. 1 |
1626 |
Sensor prop. 1 |
1627 |
Sensor prop. 2 |
1628 |
Sensor prop. 3 |
1629 |
Simulation 1 |
1630 |
Simulation 2 |
1631 |
Simulation 3 |
1632 |
Input simulation |
1633 |
Deactiv. SIL/WHG |
1634 |
SIL/WHG confirm. |
1635 |
abort_Window_SILSequence_SequenceMethod_1 |
1636 |
Config. area |
1637 |
Simulation |
1638 |
This wizard guides you through the commissioning procedure for the device.
Enter or select the appropriate value for each parameter. These values are immediately written to the device.
When all required values have been entered on a page, click 'Next' to switch to the next page.
After finishing the last page, click 'End of sequence' to close the wizard. The setup is now complete.
Note:
If the wizard is cancelled before all necessary parameters have been set, the device may be in an undefined state. A reset to the default settings is recommended in this case.
|
1639 |
Next |
1640 |
The device is locked and must be unlocked before it can be commissioned. |
1641 |
Previous |
1642 |
This page summarizes the most important data characterizing the device. Some of the parameters can be edited, others are displayed for information only. |
1643 |
Applic. adjustm. |
1644 |
Meas. adjust. |
1645 |
'Empty calibration' and 'Full calibration' define the measuring span. |
1646 |
For vessels smaller than 1m (3.3ft) the factory map stored in the device will be used. Therefore it is not necessary to record a map in the tank or silo. |
1647 |
The mapping is used to suppress static interference signals which may be generated by internal tank or silo fittings. |
1648 |
Output settings |
1649 |
Configuration of current output 1 |
1650 |
Configuration of the HART output.
Up to four HART variables can be transmitted via the HART protocol.
At the same time they are indicated on the Dashboard (homepage) of the device. |
1651 |
Configuration of current output 2 |
1652 |
Configuration of the switch output |
1653 |
End of comm. |
1654 |
The setup has been successfully completed. The device is now ready for the measuring task.
Click 'End of sequence' to close the wizard.
Note:
To check the signals, the safety settings and to document the measuring point: Click on 'Additional settings'. |
1655 |
Addit. functions |
1656 |
End of sequence |
1657 |
Ch. outp. signal |
1658 |
The envelope curve (signal curve) gives information about the current measuring situation / measuring conditions and can be used for diagnostic purposes. |
1659 |
The simulation can be used to check the configuration of the device and of connected evaluation units.
Note:
After checking the configuration, the simulation must be deactivated. No measurement is taking place as long as a simulation is active.
|
1660 |
Doc. meas. point |
1661 |
Backup to device display?
Create a backup copy of the HistoROM data into the display module. These data can be used to restore the measuring point.
Note:
Storing a backup into the display may take some seconds. |
1662 |
>>Add. settings |
1663 |
<<Cancel>> |
1664 |
<<End of sequence>> |
1665 |
<<Previous |
1666 |
Page_Number_Validity |
1667 |
>>Next |
1668 |
Menu not available |
1669 |
abort_HH_SILSequence_SequenceMethod_1 |
1670 |
Upload variables |
1671 |
Output curr. |
1672 |
Line recorder |
1673 |
Line rec. PV/SV |
1674 |
Line rec. TV/QV |
1675 |
Measured Values |
1676 |
Instrument health status |
1677 |
HART Diagnostics |
1678 |
Device Status |
1679 |
Status Byte 0 |
1680 |
Status Byte 1 |
1681 |
Status Byte 2 |
1682 |
Status Byte 3 |
1683 |
Status Byte 4 |
1684 |
Status Byte 5 |
1685 |
Status Byte 14 |
1686 |
Status Byte 15 |
1687 |
Status Byte 16 |
1688 |
Hart diagnosis |
1689 |
HartLogo |
1690 |
Configuration Flag Reset |
1691 |
Commands reset the configuration flag. |
1692 |
Micropilot 5x |
1693 |
Endress+Hauser |
1694 |
Failure |
1695 |
Out of Specification |
1696 |
Function Check |
1697 |
F282 Data storage
Remedy information
1. Restart device
2. Contact service |
1698 |
F283 Memory content
Remedy information
1. Transfer data or reset device
2. Contact service |
1699 |
C411 Up-/download active
Remedy information
Up-/download active, please wait |
1700 |
C431 Trim X
Remedy information
Carry out trim |
1701 |
C491 Current output X simulation
Remedy information
Deactivate simulation |
1702 |
F435 Linearization
Remedy information
Check linearization table |
1703 |
C485 Simulation measured value
Remedy information
Deactivate simulation |
1704 |
F242 Software incompatible
Remedy information
1. Check software
2. Flash or change main electronics module |
1705 |
F261 Electronic modules
Remedy information
1. Restart device
2. Check electronic modules
3. Change I/O Modul or main electronics |
1706 |
F262 Module connection
Remedy information
1. Check module connections
2. Change electronic modules |
1707 |
F437 Configuration incompatible
Remedy information
1. Restart device
2. Contact service |
1708 |
M438 Dataset
Remedy information
1. Check data set file
2. Check device configuration
3. Up- and download new configuration |
1709 |
C484 Failure mode simulation
Remedy information
Deactivate simulation |
1710 |
F803 Current loop
Remedy information
1. Check wiring
2. Change I/O module |
1711 |
F276 I/O module faulty
Remedy information
1. Restart device
2. Change I/O module |
1712 |
M311 Electronic failure
Remedy information
Maintenance required!
1. Do not perform reset
2. Contact service |
1713 |
F410 Data transfer
Remedy information
1. Check connection
2. Retry data transfer |
1714 |
F273 Main electronic failure
Remedy information
1. Emergency operation via display
2. Change main electronics |
1715 |
F275 I/O module defective
Remedy information
Change I/O module |
1716 |
S441 Current output X
Remedy information
1. Check process
2. Check current output settings |
1717 |
C494 Switch output simulation
Remedy information
Deactivate simulation switch output |
1718 |
S825 Operating temperature
Remedy information
1. Check ambient temperature
2. Check process temperature |
1719 |
C495 Diagnostic event simulation
Remedy information
Deactivate simulation |
1720 |
950 Advanced diagnostic X occured
Remedy information
Maintain your diagnostic event |
1721 |
C412 Processing download
Remedy information
Download active, please wait |
1722 |
C585 Simulation distance
Remedy information
Deactivate simulation |
1723 |
S921 Change of reference
Remedy information
1. Check reference configuration
2. Check pressure
3. Check sensor |
1724 |
941 Echo lost
Remedy information
Check parameter 'DC value' |
1725 |
942 In safety distance
Remedy information
1. Check level
2. Check safety distance
3. Reset self holding |
1726 |
S943 In blocking distance
Remedy information
Reduced accuracy
Check level |
1727 |
F252 Modules incompatible
Remedy information
1. Check if correct electronic modul is plugged
2. Replace electronic module |
1728 |
F270 Main electronic failure
Remedy information
Change main electronic module |
1729 |
F271 Main electronic failure
Remedy information
1. Restart device
2. Change main electronic module |
1730 |
F272 Main electronic failure
Remedy information
1. Restart device
2. Contact service |
1731 |
S801 Energy too low
Remedy information
Increase supply voltage |
1732 |
C586 Record map
Remedy information
Recording of mapping
please wait |
1733 |
Level Dev fmly |
1734 |
Level Class |
1735 |
Level Fmly stat |
1736 |
Temp Update Period |
1737 |
7d |
1738 |
PrimCstOut_Val_1 Unit |
1739 |
Level PDQ |
1740 |
Level LS |
1741 |
8.3f |
1742 |
Update Period |
1743 |
FilteredDistance_1 Unit |
1744 |
ClampingVoltage_1 Unit |
1745 |
ElectronicTemperature_1 Unit |
1746 |
AbsoluteEchoAmplitude_1 Unit |
1747 |
RelativeEchoAmplitude_1 Unit |
1748 |
IntegralForRingingDetection_1 Unit |
1749 |
DebugValue_1 Unit |
1750 |
AnalogOutputValue_1 Unit |
1751 |
AnalogOutputValue_2 Unit |
1752 |
0x00 |
1753 |
0x80 |
1754 |
0x04 |
1755 |
0x84 |
1756 |
0x01 |
1757 |
0x81 |
1758 |
0x08 |
1759 |
0x88 |
1760 |
0x02 |
1761 |
0x82 |
1762 |
0x10 |
1763 |
0x20 |
1764 |
0xA0 |
1765 |
Event buf. sel. |
1766 |
Event buf. sel. : 1-10 |
1767 |
Event buf. sel. : 11-20 |
1768 |
Event buf. sel. : 21-30 |
1769 |
Event buf. sel. : 31-40 |
1770 |
Event buf. sel. : 41-50 |
1771 |
Event buf. sel. : 51-60 |
1772 |
Event buf. sel. : 61-70 |
1773 |
Event buf. sel. : 71-80 |
1774 |
Event buf. sel. : 81-90 |
1775 |
Event buf. sel. : 91-100 |
1776 |
Event list |
1777 |
Status + Remedy |
1778 |
Event |
1779 |
No Event |
1780 |
View trend |
1781 |
Displ. sel. curv |
1782 |
Maximum |
1783 |
Minimum |
1784 |
Y Max: |
1785 |
Y Min: |
1786 |
Unit |
1787 |
mrkBlockingDistance |
1788 |
BD |
1789 |
mrkFull |
1790 |
F |
1791 |
mrkEmpty |
1792 |
E |
1793 |
mrkTankHeight |
1794 |
TH |
1795 |
Envelope curve |
1796 |
XDecimationValue_Display_EC_ECCurveEcho |
1797 |
corr_x_min_Display_EC_ECCurveEcho |
1798 |
XDecimationValue_Display_ECAndMap_ECCurveEcho |
1799 |
corr_x_min_Display_ECAndMap_ECCurveEcho |
1800 |
Map |
1801 |
XDecimationValue_Display_ECAndMap_ECCurveMap |
1802 |
corr_x_min_Display_ECAndMap_ECCurveMap |
1803 |
XDecimationValue_Display_ECAndMapAndEWC_ECCurveEcho |
1804 |
corr_x_min_Display_ECAndMapAndEWC_ECCurveEcho |
1805 |
Weighting curve |
1806 |
XDecimationValue_Display_ECAndMapAndEWC_ECCurveWeighting |
1807 |
corr_x_min_Display_ECAndMapAndEWC_ECCurveWeighting |
1808 |
XDecimationValue_Display_ECAndMapAndEWC_ECCurveMap |
1809 |
corr_x_min_Display_ECAndMapAndEWC_ECCurveMap |
1810 |
XDecimationValue_Display_ECAndRawEC_ECCurveEcho |
1811 |
corr_x_min_Display_ECAndRawEC_ECCurveEcho |
1812 |
Raw env.curve |
1813 |
XDecimationValue_Display_ECAndRawEC_ECCurveRawEcho |
1814 |
corr_x_min_Display_ECAndRawEC_ECCurveRawEcho |
1815 |
XDecimationValue_Display_ECAndRef_ECCurveEcho |
1816 |
corr_x_min_Display_ECAndRef_ECCurveEcho |
1817 |
Reference curve |
1818 |
XDecimationValue_Display_ECAndRef_ECCurveRefEcho |
1819 |
corr_x_min_Display_ECAndRef_ECCurveRefEcho |
1820 |
NumberOfPointsHK |
1821 |
Read curve |
1822 |
Select. curves.. |
1823 |
Envelope + Map |
1824 |
Envelope+Map+EWC |
1825 |
Envelope+Rawsig. |
1826 |
Envelope + Ref. |
1827 |
Status preparation Hüllkurve |
1828 |
X Min: |
1829 |
X Max: |
1830 |
Data on position |
1831 |
X1 / Y1 |
1832 |
Select curves to display |
1833 |
Progress - Read curves |
1834 |
Loop Warning Variables |
1835 |
Loop Warning Variables- Variables that display a warning message before new values are sent. |
1836 |
PV Analog Channel Saturated |
1837 |
PV Analog Channel Fixed |
1838 |
Wireless |
1839 |
WirelessHART Device |
1840 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
1841 |
Primary |
1842 |
Primary Analog Channel |
1843 |
Secondary |
1844 |
Secondary Analog Channel |
1845 |
Tertiary |
1846 |
Tertiary Analog Channel |
1847 |
Quaternary |
1848 |
Quaternary Analog Channel |
1849 |
Quinary |
1850 |
Quinary Analog Channel |
1851 |
Critical Power Failure |
1852 |
Lock all |
1853 |
Trim not supported |
1854 |
Configuration cannot be changed |
1855 |
Locked by gateway |
1856 |
Analog Input Channel |
1857 |
Analog Output Channel |
1858 |
Secondary Analog Channel Saturated |
1859 |
Tertiary Analog Channel Saturated |
1860 |
Quaternary Analog Channel Saturated |
1861 |
Quinary Analog Channel Saturated |
1862 |
Secondary Analog Channel Fixed |
1863 |
Tertiary Analog Channel Fixed |
1864 |
Quaternary Analog Channel Fixed |
1865 |
Quinary Analog Channel Fixed |
1866 |
Simulation active |
1867 |
The device is in simulation mode and the level output is not representative of the process. |
1868 |
Non-Volatile memory failure |
1869 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
1870 |
Volatile memory error |
1871 |
The RAM memory check is invalid or maybe corrupt |
1872 |
Watchdog reset executed |
1873 |
A watchdog reset has been performed |
1874 |
Voltage conditions out of range |
1875 |
A voltage condition is outside its allowable range |
1876 |
Environmental conditions out of range |
1877 |
An internal or environmental condition is beyond acceptable limits. |
1878 |
Electronic failure |
1879 |
A hardware problem not related to the sensor has been detected. |
1880 |
Subdevice list changed |
1881 |
Duplicate master detected |
1882 |
Capacity Denied |
1883 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
1884 |
Bandwidth allocation pending |
1885 |
Block transfer pending |
1886 |
Battery life |
1887 |
Percent range |
1888 |
Loop current |
1889 |
Primary variable |
1890 |
Secondary variable |
1891 |
Tertiary variable |
1892 |
Quaternary variable |
1893 |
Read receive time |
1894 |
Write date and time |
1895 |
Non-Volatile Clock |
1896 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
1897 |
Clock Uninitialized |
1898 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
1899 |
No restrictions |
1900 |
SI Only |
1901 |
Restricted to SI Unit codes only |
1902 |
Process automation device |
1903 |
Discrete device |
1904 |
Hybrid:Process automation+discrete |
1905 |
I/O System |
1906 |
WirelessHART Process automation device |
1907 |
WirelessHART Discrete device |
1908 |
WirelessHART Process automation+discrete |
1909 |
WirelessHART Gateway |
1910 |
WirelessHART Access point |
1911 |
WirelessHART Process adapter |
1912 |
WirelessHART Discrete adapter |
1913 |
WirelessHART enabled handheld/portable maintenance tool |
1914 |
Device Profile |
1915 |
US |
1916 |
United States of America |
1917 |
JP |
1918 |
Japan |
1919 |
DE |
1920 |
Germany |
1921 |
FR |
1922 |
France |
1923 |
ES |
1924 |
Spain |
1925 |
RU |
1926 |
Russian Federation |
1927 |
CN |
1928 |
People's Republic of China |
1929 |
Secondary Master |
1930 |
Primary Master |
1931 |
Device Diagnostic Status 0 |
1932 |
Device Diagnostic Status 1 |
1933 |
I/O and Subdevice Status |
1934 |
WirelessHART Status |
1935 |
Time Set Option |
1936 |
Real Time Clock Flags |
1937 |
Country |
1938 |
Country of intended device installation |
1939 |
SI Unit Control |
1940 |
Indicates if device should only display SI unit codes |
1941 |
Burst Trigger Units |
1942 |
Enable on token-passing data link layer only |
1943 |
Enable on TDMA data link layer only |
1944 |
Enable on both TDMA and token-passing data link layer |
1945 |
Burst Trigger Class |
1946 |
Continuous |
1947 |
The Burst Message is published continuously at (worst case) the Minimum Update Period. |
1948 |
Window |
1949 |
The Burst Message is triggered when the source value deviates more than the specified trigger value |
1950 |
Rising |
1951 |
The Burst Message is triggered when source value Rises Above the specified trigger value. |
1952 |
Falling |
1953 |
The Burst Message is triggered when the source value Falls Below the specified trigger value. |
1954 |
On-change |
1955 |
The Burst Message is triggered when any value in the message changes. |
1956 |
Off |
1957 |
Enable event notification on token-passing data link layer |
1958 |
Enable event notification on TDMA data link layer |
1959 |
Enable event notification on TDMA and token-passing data link layer |
1960 |
Configuration changed event pending |
1961 |
Device status event pending |
1962 |
More status available event pending |
1963 |
Wired HART Enabled |
1964 |
Enabled on Wired HART device connection only |
1965 |
Wireless HART Enabled |
1966 |
Enabled on WirelessHART device connection only |
1967 |
Both Wired and WirelessHart Enabled |
1968 |
Enabled on both Wired and WirelessHART connections |
1969 |
Burst Msg Trigger Mode |
1970 |
Event Status |
1971 |
Event Notification Control |
1972 |
Device Status Mask |
1973 |
Ext dev status Mask |
1974 |
Device Diagnostic Status 0 Mask |
1975 |
Device Diagnostic Status 1 Mask |
1976 |
Device Diagnostic Status 2 Mask |
1977 |
Device Diagnostic Status 3 Mask |
1978 |
AO saturated Mask |
1979 |
AO fixed Mask |
1980 |
Latched Device Status |
1981 |
Operate mode Mask |
1982 |
Not Defined |
1983 |
Latched Ext dev status |
1984 |
Latched Device Diagnostic Status 0 |
1985 |
Latched Device Diagnostic Status 1 |
1986 |
Latched Device Diagnostic Status 2 |
1987 |
Latched Device Diagnostic Status 3 |
1988 |
Latched AO saturated |
1989 |
Latched AO fixed |
1990 |
Latched Operate Mode |
1991 |
Time Stamp |
1992 |
Relative time value on network |
1993 |
8u |
1994 |
Dynamic Variables Returned for Device Variables |
1995 |
Command Response Truncated |
1996 |
Configuration Change Counter Mismatch |
1997 |
Status bytes mismatch |
1998 |
count |
1999 |
Device Variable |
2000 |
Variable to trim |
2001 |
Actual diagnos. |
2002 |
: %{SPV_CurrentSysConditionUnion_1} |
2003 |
Carry out trim
(Service ID: 4) |
2004 |
Change main electronic module
(Service ID: 87) |
2005 |
1. Check reference configuration
2. Check pressure
3. Check sensor
(Service ID: 88) |
2006 |
1. Check level
2. Check safety distance
3. Reset self holding
(Service ID: 94) |
2007 |
Reduced accuracy
Check level
(Service ID: 95) |
2008 |
1. Restart device
2. Contact service
(Service ID: 96) |
2009 |
Increase supply voltage
(Service ID: 97) |
2010 |
1. Restart device
2. Contact service
(Service ID: 98) |
2011 |
1. Check software
2. Flash or change main electronics module
(Service ID: 103) |
2012 |
Up-/download active, please wait
(Service ID: 104) |
2013 |
Up-/download active, please wait
(Service ID: 105) |
2014 |
1. Check data set file
2. Check device configuration
3. Up- and download new configuration
(Service ID: 106) |
2015 |
1. Check if correct electronic modul is plugged
2. Replace electronic module
(Service ID: 107) |
2016 |
Up-/download active, please wait
(Service ID: 108) |
2017 |
Change main electronic module
(Service ID: 109) |
2018 |
Check linearization table
(Service ID: 117) |
2019 |
Check parameter 'DC value'
(Service ID: 118) |
2020 |
Change main electronic module
(Service ID: 120) |
2021 |
1. Restart device
2. Contact service
(Service ID: 121) |
2022 |
Change I/O module
(Service ID: 122) |
2023 |
1. Restart device
2. Change I/O module
(Service ID: 123) |
2024 |
Change main electronic module
(Service ID: 124) |
2025 |
1. Restart device
2. Change main electronic module
(Service ID: 125) |
2026 |
1. Check module connections
2. Change electronic modules
(Service ID: 126) |
2027 |
Change main electronic module
(Service ID: 127) |
2028 |
Change main electronic module
(Service ID: 128) |
2029 |
1. Restart device
2. Change I/O module
(Service ID: 129) |
2030 |
1. Restart device
2. Change I/O module
(Service ID: 130) |
2031 |
Change main electronic module
(Service ID: 132) |
2032 |
1. Check ambient temperature
2. Check process temperature
(Service ID: 133) |
2033 |
1. Check ambient temperature
2. Check process temperature
(Service ID: 135) |
2034 |
1. Check ambient temperature
2. Check process temperature
(Service ID: 136) |
2035 |
1. Check connection
2. Retry data transfer
(Service ID: 139) |
2036 |
Deactivate simulation switch output
(Service ID: 143) |
2037 |
1. Restart device
2. Check electronic modules
3. Change I/O Modul or main electronics
(Service ID: 149) |
2038 |
1. Check process
2. Check current output settings
(Service ID: 153) |
2039 |
1. Transfer data or reset device
2. Contact service
(Service ID: 158) |
2040 |
Change main electronic module
(Service ID: 159) |
2041 |
Change main electronic module
(Service ID: 165) |
2042 |
Change main electronic module
(Service ID: 166) |
2043 |
Change main electronic module
(Service ID: 167) |
2044 |
Change main electronic module
(Service ID: 171) |
2045 |
1. Restart device
2. Change main electronic module
(Service ID: 172) |
2046 |
1. Check wiring
2. Change I/O module
(Service ID: 173) |
2047 |
Change main electronic module
(Service ID: 174) |
2048 |
Change main electronic module
(Service ID: 177) |
2049 |
1. Restart device
2. Contact service
(Service ID: 178) |
2050 |
Change main electronic module
(Service ID: 179) |
2051 |
Change main electronic module
(Service ID: 180) |
2052 |
Change main electronic module
(Service ID: 181) |
2053 |
1. Check process
2. Check current output settings
(Service ID: 182) |
2054 |
Change main electronic module
(Service ID: 183) |
2055 |
1. Transfer data or reset device
2. Contact service
(Service ID: 225) |
2056 |
Maintenance required!
1. Do not perform reset
2. Contact service
(Service ID: 226) |
2057 |
1. Emergency operation via display
2. Change main electronics
(Service ID: 229) |
2058 |
1. Emergency operation via display
2. Change main electronics
(Service ID: 230) |
2059 |
Recording of mapping
please wait
(Service ID: 352) |
2060 |
Maintain your diagnostic event
(Service ID: 359) |
2061 |
Download active, please wait
(Service ID: 516) |
2062 |
Change main electronic module
(Service ID: 659) |
2063 |
Change main electronic module
(Service ID: 660) |
2064 |
Change main electronic module
(Service ID: 661) |
2065 |
Change main electronic module
(Service ID: 662) |
2066 |
Deactivate simulation |
2067 |
Assign signal 1 (74) |
2068 |
Assign signal 2 (74) |
2069 |
Reset min/max1 |
2070 |
Reset min/max2 |
2071 |
Config. managem. (39) |
2072 |
Reset min/max |
2073 |
Confirm distance (11) |
2074 |
History reset |
2075 |
Start dev. check |
2076 |
Debug index |
2077 |
Debug sub index |
2078 |
Start self check |
2079 |
Res.min/max temp |
2080 |
Bin type |
2081 |
Adv. conditions |
2082 |
Code incorrect |
2083 |
Set write prot. |
2084 |
Clear event list |
2085 |
Clear logging |
2086 |
%{0}% |
2087 |
Table not read |
2088 |
Tab. not written |
2089 |
Res. write prot. |
2090 |
SIL/WHG prepar. |
2091 |
: %{SIL_Prepare_1} |
2092 |
Level linearized (93) |
2093 |
: %{LE_PrimCstOut_Val_1} |
2094 |
Output curr. 1 |
2095 |
: %{CO_OutValue_1} |
2096 |
Char.test string |
2097 |
: %{SIL_CharacterTestString_1} |
2098 |
SIL confirmation |
2099 |
: %{SIL_ConfirmCharacterTest_1} |
2100 |
Empty calibr. |
2101 |
: %{SIL_ReadBackLEEmpty_1} |
2102 |
: %{SIL_ConfirmLEEmpty_1} |
2103 |
Full calibr. |
2104 |
: %{SIL_ReadBackLEFull_1} |
2105 |
: %{SIL_ConfirmLEFull_1} |
2106 |
Tank/silo height |
2107 |
: %{SIL_ReadBackSBEmptyDistance_1} |
2108 |
: %{SIL_ConfirmSBEmptyDistance_1} |
2109 |
: %{SIL_ReadBackSBTankTypeEnum_1} |
2110 |
: %{SIL_ConfirmSBTankType_1} |
2111 |
: %{SIL_ReadBackSBBinTypeEnum_1} |
2112 |
: %{SIL_ConfirmSBBinType_1} |
2113 |
Max. fill. speed |
2114 |
: %{SIL_ReadBackSBFillingSpeedRangeEnum_1} |
2115 |
: %{SIL_ConfirmSBFillingSpeedRange_1} |
2116 |
Max. drain speed |
2117 |
: %{SIL_ReadBackSBDrainingSpeedRangeEnum_1} |
2118 |
: %{SIL_ConfirmSBDrainingSpeedRange_1} |
2119 |
: %{SIL_ReadBackSBSpecProcConditionEnum_1} |
2120 |
: %{SIL_ConfirmSBSpecialProcessCondition_1} |
2121 |
Tube diameter |
2122 |
: %{SIL_ReadBackSBTubeDiameter_1} |
2123 |
: %{SIL_ConfirmSBTubeDiameter_1} |
2124 |
Conf.funct.test |
2125 |
End of sequence |
2126 |
Locking status |
2127 |
Execute Configuration Flag Reset? |
2128 |
Preparation in progress,
please wait! |
2129 |
Prepare busy |
2130 |
%{SPV_FilterOptions_1} : |
2131 |
No Event |
2132 |
Event buf. sel. |
2133 |
Close |
2134 |
select |
2135 |
Next |
2136 |
Envelope curve |
2137 |
100% |
2138 |
Weighting curve |
2139 |
Raw env.curve |
2140 |
Reference curve |
2141 |
ABCD |
2142 |
0 |
2143 |
B |
2144 |
C |
2145 |
D |
2146 |
G |
2147 |
H |
2148 |
I |
2149 |
J |
2150 |
L |
2151 |
M |
2152 |
N |
2153 |
O |
2154 |
P |
2155 |
Q |
2156 |
R |
2157 |
S |
2158 |
T |
2159 |
U |
2160 |
W |
2161 |
X |
2162 |
Y |
2163 |
Z |
2164 |
This wizard guides you through the commissioning procedure for the device.
Enter or select the appropriate value for each parameter. These values are immediately written to the device.
When all required values have been entered on a page, click 'Next' to switch to the next page.
After finishing the last page, click 'End of sequence' to close the wizard. The setup is now complete.
Note:
If the wizard is cancelled before all necessary parameters have been set, the device may be in an undefined state. A reset to the default settings is recommended in this case.
|
2165 |
The device is locked and must be unlocked before it can be commissioned. |
2166 |
This page summarizes the most important data characterizing the device. Some of the parameters can be edited, others are displayed for information only. |
2167 |
'Empty calibration' and 'Full calibration' define the measuring span. |
2168 |
For vessels smaller than 1m (3.3ft) the factory map stored in the device will be used. Therefore it is not necessary to record a map in the tank or silo. |
2169 |
The mapping is used to suppress static interference signals which may be generated by internal tank or silo fittings. |
2170 |
Configuration of current output 1 |
2171 |
Configuration of the HART output.
Up to four HART variables can be transmitted via the HART protocol.
At the same time they are indicated on the Dashboard (homepage) of the device. |
2172 |
Configuration of current output 2 |
2173 |
Configuration of the switch output |
2174 |
The setup has been successfully completed. The device is now ready for the measuring task.
Click 'End of sequence' to close the wizard.
Note:
To check the signals, the safety settings and to document the measuring point: Click on 'Additional settings'. |
2175 |
The envelope curve (signal curve) gives information about the current measuring situation / measuring conditions and can be used for diagnostic purposes. |
2176 |
The simulation can be used to check the configuration of the device and of connected evaluation units.
Note:
After checking the configuration, the simulation must be deactivated. No measurement is taking place as long as a simulation is active.
|
2177 |
Backup to device display?
Create a backup copy of the HistoROM data into the display module. These data can be used to restore the measuring point.
Note:
Storing a backup into the display may take some seconds. |