0 |
TB82EC-Combined |
1 |
ABB |
2 |
Rerange-Apply values |
3 |
EC1 PV.AD |
4 |
Process Variable A/D over or under range |
5 |
Undefined |
6 |
EC3 PH.PCB |
7 |
pH/ORP/pION input PCB with Conductivity/concentration firmware |
8 |
EC4 TC.PCB |
9 |
Toroidal conductivity input PCB with 4-electrode conductivity/concentration firmware |
10 |
EC6 TE.PCB |
11 |
2-electrode conductivity input PCB with 4-electrode conductivity/concentration firmware |
12 |
PC3 DRTY.SN |
13 |
Dirty Sensor detected |
14 |
PC4 GND LP |
15 |
Ground loops present or shorted sensor cable |
16 |
PC6 HI.LOOP |
17 |
Current loop above upper range |
18 |
PC7 LO.LOOP |
19 |
Current loop below lower range value |
20 |
PC8 HI.PV |
21 |
PV above transmitter range |
22 |
PC9 LO.PV |
23 |
PV below transmitter range |
24 |
PC10 HI.TEMP |
25 |
Temperature above transmitter range |
26 |
PC11 LO.TEMP |
27 |
Temperature below transmitter range |
28 |
PC12 TEMP.AD |
29 |
Open, missing or shorted Temperature Sensor |
30 |
PC2O BAD.SEE |
31 |
Bad SEEPROM or bad input PCB assembly |
32 |
PC21 NO.F.CAL |
33 |
Missing factory cal or nonfunctional SEEPROM |
34 |
PC22 BLNK.EE |
35 |
Blank microprocessor EEPROM |
36 |
PC30 R0.F.CAL |
37 |
Out of range or missing factory cal for conductivity circuit range zero |
38 |
PC31 R1.F.CAL |
39 |
Out of range or missing factory cal for conductivity circuit range one |
40 |
PC32 R2.F.CAL |
41 |
Out of range or missing factory cal for conductivity circuit range two |
42 |
PC33 R3.F.CAL |
43 |
Out of range or missing factory cal for conductivity circuit range three |
44 |
PC34 R4.F.CAL |
45 |
Out of range or missing factory cal for conductivity circuit range four |
46 |
PC35 G0.F.CAL |
47 |
Out of range or missing factory cal for ground loop circuit range zero |
48 |
PC36 G1.F.CAL |
49 |
Out of range or missing factory cal for ground loop circuit range one |
50 |
PC37 G2.F.CAL |
51 |
Out of range or missing factory cal for ground loop circuit range two |
52 |
PC38 G3.F.CAL |
53 |
Out of range or missing factory cal for ground loop circuit range three |
54 |
PC39 G4.F.CAL |
55 |
Out of range or missing factory cal for ground loop circuit range four |
56 |
PC45 BA.F.CAL |
57 |
Out of range or missing factory cal for 3-k ohm Balco temp.compensator |
58 |
PC46 PT.F.CAL |
59 |
Out of range or missing factory cal for PT100 temp. compensator |
60 |
PC47 RT.F.CAL |
61 |
Out of range or missing factory cal for 4.75-k ohm RTD network temp. compensator |
62 |
PC50 R0.CHKS |
63 |
Incorrect or missing conductivity circuit range zero checksum |
64 |
PC51 R1.CHKS |
65 |
Incorrect or missing conductivity circuit range one checksum |
66 |
PC52 R2.CHKS |
67 |
Incorrect or missing conductivity circuit range two checksum |
68 |
PC53 R3.CHKS |
69 |
Incorrect or missing conductivity circuit range three checksum |
70 |
PC54 R4.CHKS |
71 |
Incorrect or missing conductivity circuit range four checksum |
72 |
PC55 G0.CHKS |
73 |
Incorrect or missing ground loop circuit range zero checksum |
74 |
PC56 G1.CHKS |
75 |
Incorrect or missing ground loop circuit range one checksum |
76 |
PC57 G2.CHKS |
77 |
Incorrect or missing ground loop circuit range two checksum |
78 |
PC58 G3.CHKS |
79 |
Incorrect or missing ground loop circuit range three checksum |
80 |
PC59 G4.CHKS |
81 |
Incorrect or missing ground loop circuit range four checksum |
82 |
PC65 BA.CHKS |
83 |
Incorrect or missing 3-k ohm Balco temp. compensator checksum |
84 |
PC66 PT.CHKS |
85 |
Incorrect or missing PT100 temp. compensator checksum |
86 |
PC67 RT.CHKS |
87 |
Incorrect or missing 4.75-k ohm network temp. compensator checksum |
88 |
PC70 G.L.AD |
89 |
Ground loop signal above or below transmitter A/D range |
90 |
PC72 D.S.AD |
91 |
Dirty sensor signal above or below transmitter A/D range |
92 |
Invalid span |
93 |
Main Menu |
94 |
Temp (SV) |
95 |
Cond/Conc (TV) |
96 |
Uncomp Cond (QV) |
97 |
.3f |
98 |
8.3f |
99 |
PV |
100 |
|
101 |
USL |
102 |
LSL |
103 |
Minimum Span |
104 |
Damping |
105 |
.1f |
106 |
8.1f |
107 |
7d |
108 |
.2f |
109 |
8.2f |
110 |
Primary Variable pH, ORP, pION or Ion Concentration |
111 |
Secondary variable temperature |
112 |
Temp (SV) unit |
113 |
Secondary variable temperature engineering units |
114 |
SV-Temperature |
115 |
Secondary Variable Temperature |
116 |
Device Tertiary Variable (TV). TV = Concentration value when PV type = Conductivity. TV = Conductivity value when PV type = Concentration. |
117 |
Cond/Conc (TV) unit |
118 |
Tertiary variable conductivity or concentration engineering units |
119 |
Quaternary variable temp-uncompensated conductivity |
120 |
Uncomp Cond (QV) unit |
121 |
Quaternary variable uncompensated conductivity engineering units |
122 |
Rerange-Enter values |
123 |
PV type |
124 |
Primary Value (PV) type selection. When PV type = Conductivity, PV value = Conductivity and TV value = Concentration. When PV type = Concentration, PV value = Concentration and TV value = Conductivity. |
125 |
Conductivity |
126 |
|
127 |
Concentration |
128 |
Snsr group |
129 |
Three sensor groups are applied and defined by the sensor cell constant: A, B and C. |
130 |
Group A |
131 |
Sensor Group A: maximum range 0 to 1999 mS/cm |
132 |
Group B |
133 |
Sensor Group B: maximum range 0 to 1999 uS/cm |
134 |
Group C |
135 |
Sensor Group C: maximum range 0 to 199.9 uS/cm |
136 |
Snsr diagnostics |
137 |
Sensor Diagnostics selection determines whether certain sensor diagnostics are enabled or disabled |
138 |
Diagnostics not active |
139 |
Diagnostics are active |
140 |
Solution type |
141 |
The solution type defines the solute algorithm used for concentration configurations. Both predefined and user-defined concentration configurations are available. The available solution types are dependent upon the current SENSOR_GROUP. Sensor Group A: 0 to 15% NaOH, 0 to 20% NaCl, 0 to 18% HCl, 0 to 20% H2SO4, User Defined. Sensor Group B: User Defined. Sensor Group C: User Defined. |
142 |
0 to 15% NaOH |
143 |
Predefined configuration: NaOH |
144 |
0 to 20% NaCl |
145 |
Predefined configuration: NaCl |
146 |
0 to 18% HCl |
147 |
Predefined configuration: HCl |
148 |
0 to 20% H2SO4 |
149 |
Predefined configuration: H2SO4 |
150 |
User Defined |
151 |
User-defined configuration option is only available for Sensor Groups B and C |
152 |
Concen curve name |
153 |
This is a six character text name for the concentration curve. It could be modified in user-defined concentration configuration |
154 |
User def conc unit |
155 |
Engineering units for user defined concentration curve This will be used as the concentration value units when a user defined concentration curve is selected. |
156 |
Concen range |
157 |
The concentration range can be set when the solution type is set to user defined. For all other solution types it is read-only |
158 |
0 to 1999 |
159 |
Concentration range: 0 to 1999 |
160 |
0 to 199.9 |
161 |
Concentration range: 0 to 199.9 |
162 |
0 to 19.99 |
163 |
Concentration range: 0 to 19.99 |
164 |
0 to 1.999 |
165 |
Concentration range: 0 to 1.999 |
166 |
Transmitter Busy - Cannot Process Command |
167 |
Access Restricted. Solution type is not user-defined |
168 |
Temp snsr type |
169 |
Temperature sensor type |
170 |
Balco |
171 |
Temperature sensor type 3k Balco |
172 |
PT 100 |
173 |
Temperature sensor type PT 100 |
174 |
4.75K RTD |
175 |
Temperature sensor type 4.75K RTD |
176 |
None |
177 |
A temperature sensor is not being used. |
178 |
Temp comp type |
179 |
Determines the type of Temperature Compensation algorithm applied to the Primary Value |
180 |
Manual |
181 |
Manual Temperature Compensation - This state uses a fixed manually set temperature value in the temperature compensation algorithm. |
182 |
Automatic |
183 |
Automatic Temperature Compensation - This state uses the measured temperature value from the temperature sensor in the temperature compensation algorithm. |
184 |
Manual temp unit |
185 |
Manual Temp. |
186 |
Manual Temperature value is used in the temp comp algorithm when the temp comp type is MANUAL. |
187 |
Auto TC option |
188 |
This is valid when temp comp type is Automatic. The Automatic Temperature Compensation option applies an algorithm that adjusts for the temperature effect of a solute. The available options are dependent upon the current SENSOR_GROUP. Sensor Group A: Std KCl, TC Coeff, NaOH, NaCl, HCl, H2SO4, User Defined. Sensor Group B: Std KCl, TC Coeff, User Defined. Sensor Group C: Std KCl, TC Coeff, Pure H2O, User Defined. |
189 |
Standard KCl |
190 |
Temp comp based on Standard 0.1N KCl |
191 |
TC Coefficient |
192 |
Temp comp is based on percent change of conductivity from an adjustable reference temperature (e.g., typically 25 deg C) per deg C. The value is adjustable between 0 and 9.99% per deg-C. |
193 |
NaOH |
194 |
Temp comp is based on 0 to 15% NaOH |
195 |
NaCl |
196 |
Temp comp is based on 0 to 20% NaCl |
197 |
HCl |
198 |
Temp comp is based on 0 to 18% HCl |
199 |
H2SO4 |
200 |
Temp comp is based on 0 to 20% H2SO4 |
201 |
Pure H2O |
202 |
Temp comp is based on Pure water with either a neutral salt, acid or base. After making this selection, move on to the temp_pure_h2o parameter and select the desired Pure Water options. This selection is restricted to Sensor Group C |
203 |
User defined |
204 |
Temp comp is defined as ratio of uncompensated conductivity over compensated conductivity for a specific set of temperatures. |
205 |
Auto TC pure H2O options |
206 |
This is valid when temp-comp type is Automatic and Auto TC option is Pure H2O. This parameter provides Pure H2O option selection for temp-comp. This selection is restricted to Sensor Group C. |
207 |
Neutral |
208 |
Temp comp is based on Pure water with neutral salt This selection is restricted to Sensor Group C |
209 |
Acid |
210 |
Temp comp is based on Pure water with Acid. This selection is restricted to Sensor Group C |
211 |
Base |
212 |
Temp comp is based on Pure water with Base. This selection is restricted to Sensor Group C |
213 |
Temp comp coeff |
214 |
Temperature Compensation Coefficient: This is valid when tem-comp type is Automatic and Auto TC option is TC-coeff. The Temp Coeff is applied as percent of change of conductivity from a reference temp per deg C. Valid range is 0 to 9.99% per deg C. |
215 |
% per Deg C |
216 |
Variable ref temp |
217 |
Variable Reference Temperature provides the ability to use use any temp as the reference temp used to determine the temp-compensated conductivity value (i.e., Primary value). |
218 |
Deg C |
219 |
Access Restricted |
220 |
Temp 1 |
221 |
Temp 1 of user defined temperature coefficient. First end point of the curve. Valid only when Auto-TC option is user-defined |
222 |
.0f |
223 |
8.0f |
224 |
Temp 2 |
225 |
Temp 2 of user defined temperature coefficient. Valid only when Auto-TC option is user-defined |
226 |
Temp 3 |
227 |
Temp 3 of user defined temperature coefficient. Valid only when Auto-TC option is user-defined |
228 |
Temp 4 |
229 |
Temp 4 of user defined temperature coefficient. Valid only when Auto-TC option is user-defined |
230 |
Temp 5 |
231 |
Temp 5 of user defined temperature coefficient. Valid only when Auto-TC option is user-defined |
232 |
Temp 6 |
233 |
Temp 6 of user defined temperature coefficient. Last end point of the curve. Valid only when Auto-TC option is user-defined |
234 |
K1/Kref |
235 |
Ratio of uncompensated conductivity at Temp 1 to conductivity at reference temperature (K1/Kref). First endpoint of the curve. Valid only when Auto-TC option is user-defined |
236 |
% |
237 |
K2/Kref |
238 |
Ratio of uncompensated conductivity at Temp 2 to conductivity at reference temperature (K2/Kref). Valid only when Auto-TC option is user-defined |
239 |
K3/Kref |
240 |
Ratio of uncompensated conductivity at Temp 3 to conductivity at reference temperature (K3/Kref). Valid only when Auto-TC option is user-defined |
241 |
K4/Kref |
242 |
Ratio of uncompensated conductivity at Temp 4 to conductivity at reference temperature (K4/Kref). Valid only when Auto-TC option is user-defined |
243 |
K5/Kref |
244 |
Ratio of uncompensated conductivity at Temp 5 to conductivity at reference temperature (K5/Kref). Valid only when Auto-TC option is user-defined |
245 |
K6/Kref |
246 |
Ratio of uncompensated conductivity at Temp 6 to conductivity at reference temperature (K6/Kref). Last endpoint of the curve. Valid only when Auto-TC option is user-defined |
247 |
Curve value out of limit |
248 |
Curve values not monotonic |
249 |
x1 Cond |
250 |
x1 Conductivity point of the user defined concentration curve. |
251 |
uS/cm |
252 |
x2 Cond |
253 |
x2 Conductivity point of the user defined concentration curve. |
254 |
x3 Cond |
255 |
x3 Conductivity point of the user defined concentration curve. |
256 |
x4 Cond |
257 |
x4 Conductivity point of the user defined concentration curve. |
258 |
x5 Cond |
259 |
x5 Conductivity point of the user defined concentration curve. |
260 |
x6 Cond |
261 |
x6 Conductivity point of the user defined concentration curve. |
262 |
y1 Concen |
263 |
y1 Concentration point corresponding to x1 Conductivity in the user defined concentration curve |
264 |
y2 Concen |
265 |
y2 Concentration point corresponding to x1 Conductivity in the user defined concentration curve |
266 |
y3 Concen |
267 |
y3 Concentration point corresponding to x1 Conductivity in the user defined concentration curve |
268 |
y4 Concen |
269 |
y4 Concentration point corresponding to x1 Conductivity in the user defined concentration curve |
270 |
y5 Concen |
271 |
y5 Concentration point corresponding to x1 Conductivity in the user defined concentration curve |
272 |
y6 Concen |
273 |
y6 Concentration point corresponding to x1 Conductivity in the user defined concentration curve |
274 |
LCD secondry disp |
275 |
The parameter sets the HMI's local LCD secondary display area to one of several options. |
276 |
Temp deg-C |
277 |
Temperature in deg C |
278 |
Temp deg-F |
279 |
Temperature in deg F |
280 |
Output current |
281 |
Analog Output current in mA |
282 |
Sensor type |
283 |
Conductivity sensor type |
284 |
Sensor group |
285 |
Temp comped conductivity |
286 |
Temperature compensated conductivity value. This option is available when PV = CONCENTRATION |
287 |
Concen text |
288 |
Six character concentration text. This option is available when PV = CONCENTRATION |
289 |
Temp uncomped conductivity |
290 |
Temperature uncompensated conductivity value |
291 |
SW rev |
292 |
Software revision |
293 |
Security Lock |
294 |
When ENABLED, the Security Password will be active for Security mode on local HMI. If Security Lock is disabled, then the Security mode of operation can be accessed from the local HMI without supplying the password. |
295 |
Configuration Lock |
296 |
When ENABLED, the Security Password will be active for Config mode on local HMI. Config parameters will be write protected on the HART interface. When the Configuration-Lock is DISABLED, the Config mode of operation can be accessed from the local HMI without supplying the password |
297 |
Calibration Lock |
298 |
When ENABLED, the Security Password will be active for Calibrate mode on local HMI. Calib parameters will be write protected on the HART interface. When the Calibration Lock is DISABLED, the Calibrate mode of operation can be accessed from the local HMI without supplying the password |
299 |
Output Lock |
300 |
When ENABLED, the Security Password will be active for Output mode on local HMI. Output related parameters will be write protected on the HART interface. When the Output Lock is DISABLED, the Output mode of operation can be accessed from the local HMI without supplying the password |
301 |
Secur. Passwrd 1 |
302 |
Three password digits form the Security Password. Each digit can have a value from 0 to 9. The 3-digit Password range is 000 to 999. When Secur, Config, Output or Calib Locks are ENABLED, this Security Password will be required at the local HMI to access the corresponding modes of operation. |
303 |
Secur. Passwrd 2 |
304 |
Secur. Passwrd 3 |
305 |
PV slope units |
306 |
PV Slope |
307 |
PV sensor efficiency (slope) value in percent |
308 |
PV snsr offset unit |
309 |
PV sensor offset unit |
310 |
PV offset |
311 |
PV sensor offset value. |
312 |
Temp slope units |
313 |
Temp snsr Slope |
314 |
Temperature sensor Slope |
315 |
Temp snsr offset unit |
316 |
Temperature sensor offset unit |
317 |
Temp snsr offset |
318 |
Cal Status |
319 |
PV cal offset too low |
320 |
PV cal offset too high |
321 |
PV cal slope too low |
322 |
PV cal slope too high |
323 |
Temperature cal offset warning |
324 |
Temperature cal slope warning |
325 |
Temp cal unit |
326 |
Temp cal value |
327 |
PV Slope too high |
328 |
PV Slope too low |
329 |
PV Offset too high |
330 |
PV Offset too low |
331 |
Temp Slope too high |
332 |
Temp Slope too low |
333 |
Temp Offset too high |
334 |
Temp Offset too low |
335 |
Access Restricted. Temperature value is forced |
336 |
PV value for PV cal |
337 |
Access Restricted. PV value is forced |
338 |
Busy |
339 |
Main sensor |
340 |
User def conc curve |
341 |
Temp. sensor |
342 |
User def TC curve |
343 |
HMI |
344 |
Temperature |
345 |
Analog Output |
346 |
Units |
347 |
Master reset |
348 |
Reset Cal |
349 |
Reset the process and temperature sensor calibration data to the values set at the factory |
350 |
Temp Cal |
351 |
Temperature calibration |
352 |
PV Cal |
353 |
PV Conductivity or Concentration calibration |
354 |
Refresh variables |
355 |
Read all transmitter data to refresh their values. This will update any variable that was modified via the device keypad. |
356 |
FMU860 |
357 |
DT |
358 |
DVC |
359 |
FCX |
360 |
AS800 |
361 |
340T |
362 |
340C |
363 |
344 |
364 |
Siemens Micro K |
365 |
SITRANS L |
366 |
SIPAN PH |
367 |
SITRANS P |
368 |
75SMT |
369 |
UNIDELTA |
370 |
8320 |
371 |
SX5100 |
372 |
TSV175 |
373 |
DMU |
374 |
3780 |
375 |
BM70 |
376 |
8u |
377 |
low |
378 |
high |
379 |
tmp_av |
380 |
About to Preform Master Reset |
381 |
Master Reset in
progress please wait |
382 |
Device maybe stuck in Master Reset. |
383 |
Master reset OK |
384 |
Select Calibration reset option |
385 |
Reset PV cal;Reset Temperature cal;Exit |
386 |
Current Temp value: %[.2f]{0} %{1}
Temp Compensation type: %{2} |
387 |
Select Temp Cal Units: |
388 |
Enter Temp Cal Value: |
389 |
Temp cal failed
Reason: Temp cal offset out-of-range. |
390 |
Temp cal failed
Reason: Temp cal slope out-of-range |
391 |
Temp cal success.
Temp cal slope: %[.2f]{3} %{5}
Temp cal offset: %[.2f]{4} %{6} |
392 |
Press OK when PV is stable
%0 uS/cm |
393 |
Press OK when PV is stable
%0 mS/cm |
394 |
Press OK when PV is stable
%0 |
395 |
Press OK when PV is stable
%0 ppm |
396 |
Press OK when PV is stable
%0 ppb |
397 |
Press OK when PV is stable
%0 |
398 |
Enter new value (%{1}): |
399 |
PV cal failed.
Reason: PV cal offset too low.
Do you want to retry? |
400 |
Yes;No |
401 |
PV cal failed.
Reason: PV cal offset too high.
Do you want to retry? |
402 |
PV cal failed.
Reason: PV cal slope too low.
Do you want to retry? |
403 |
PV cal failed.
Reason: PV cal slope too high.
Do you want to retry? |
404 |
PV cal success.
PV slope: %[.2f]{2} %{4}
PV offset: %[.3f]{3} %{5} |
405 |
Reading all device data, please wait. |