0 |
FSM4000 |
1 |
ABB |
2 |
Errors 1 |
3 |
empty pipe |
4 |
A/D-converter |
5 |
Driver |
6 |
Flow > 105% |
7 |
Zero return |
8 |
Database |
9 |
Totalizer |
10 |
high Alarm |
11 |
Errors 2 |
12 |
low Alarm |
13 |
ext.Database |
14 |
ext.FRAM |
15 |
old primary |
16 |
Status 2 |
17 |
Functiontest on |
18 |
Q-Simulation on |
19 |
autom. Adjust |
20 |
Error autom.Adj. |
21 |
Result functiont. |
22 |
Status 1 |
23 |
Test IOUT 1 |
24 |
Test IOUT 2 |
25 |
Test contactoutp |
26 |
Test Pulseoutput |
27 |
Adjust IOUT 1 |
28 |
Adjust IOUT 2 |
29 |
Test contactinp. |
30 |
Warnings 1 |
31 |
ext.Total. reset |
32 |
Simulation |
33 |
Test mode |
34 |
Functiontest |
35 |
Overflow F |
36 |
Overflow R |
37 |
Overflow diff. |
38 |
reverse flow Q |
39 |
Warnings 2 |
40 |
Prim.data loaded |
41 |
Update int.FRAM |
42 |
Update ext.FRAM |
43 |
Poll.Addr. > 0 |
44 |
Simulation IOUT |
45 |
Simulat. Pulse |
46 |
hold - MV |
47 |
Error Memory 1 |
48 |
M:empty pipe |
49 |
M:A/D-converter |
50 |
M:Driver |
51 |
M:Flow > 105% |
52 |
M:Zero return |
53 |
M:Database |
54 |
M:Totalizer |
55 |
M:high Alarm |
56 |
Error Memory 2 |
57 |
M:low Alarm |
58 |
M:ext.Database |
59 |
M:ext.FRAM |
60 |
M:old primary |
61 |
.2f |
62 |
Damping |
63 |
Response time 1t = 0-67% for a step flow change. |
64 |
.3f |
65 |
6.3f |
66 |
To>F |
67 |
To<R |
68 |
Unit Qmax |
69 |
ml/s |
70 |
Mililiter per second |
71 |
ml/min |
72 |
Mililiter per minute |
73 |
spcl/s |
74 |
programable unit per second |
75 |
spcl/min |
76 |
programable unit per minute |
77 |
spcl/h |
78 |
programable unit per hour |
79 |
spcl/day |
80 |
programable unit per day |
81 |
Unit totalizer |
82 |
ml |
83 |
Mililiter |
84 |
spcl |
85 |
programable unit |
86 |
Flow Sensor- Hardware that measures flow rate. |
87 |
Gross Total- Non-resettable totalizer. |
88 |
Reverse Total- Non-resettable reverse totalizer. |
89 |
Diff.total |
90 |
Diferential Total- Non-resettable reverse totalizer. |
91 |
Diagnosis |
92 |
Errors |
93 |
Error memory |
94 |
Warnings |
95 |
Status |
96 |
Device Info |
97 |
Operating |
98 |
Units |
99 |
Operating config. |
100 |
System zero |
101 |
Display mode |
102 |
Alarms |
103 |
Primary |
104 |
Converter |
105 |
Functiontest |
106 |
ToD |
107 |
Total difference totalizer value. |
108 |
µs |
109 |
mikrosecond |
110 |
Language |
111 |
Selection of the menu language. |
112 |
German |
113 |
English |
114 |
French |
115 |
Finnish |
116 |
Spain |
117 |
Italian |
118 |
Dutch |
119 |
Danish |
120 |
Swedish |
121 |
Metersize |
122 |
Display of the flowmeter primary size. Selection only available when connected to Older Models. |
123 |
1 mm 1/25 in |
124 |
1,5 mm 1/17 in |
125 |
2 mm 1/12 in |
126 |
3 mm 1/10 in |
127 |
4 mm 5/32 in |
128 |
6 mm 1/4 in |
129 |
8 mm 5/16 in |
130 |
10 mm 3/8 in |
131 |
15 mm 1/2 in |
132 |
20 mm 3/4 in |
133 |
25 mm 1 in |
134 |
32 mm 1-1/4 in |
135 |
40 mm 1-1/2 in |
136 |
50 mm 2 in |
137 |
65 mm 2-1/2 in |
138 |
80 mm 3 in |
139 |
100 mm 4 in |
140 |
125 mm 5 in |
141 |
150 mm 6 in |
142 |
200 mm 8 in |
143 |
250 mm 10 in |
144 |
300 mm 12 in |
145 |
350 mm 14 in |
146 |
400 mm 16 in |
147 |
450 mm 18 in |
148 |
500 mm 20 in |
149 |
600 mm 24 in |
150 |
700 mm 28 in |
151 |
750 mm 30 in |
152 |
800 mm 32 in |
153 |
900 mm 36 in |
154 |
1000 mm 40 in |
155 |
Selection of the units for the volume and mass flowrate measurements. The units are used for Range max., Qmax and the instantaneous display value when direct reading engineering units have been selected for the display. |
156 |
Selections of the engineering totalizer unit for the volume and mass flowrate measurements. |
157 |
Prog. Unit |
158 |
Configurable units for mass (with density) or volume flowrate (without density). |
159 |
without density |
160 |
with density |
161 |
Contact output |
162 |
The switch mode for the contact output (terminals 41/42) can be selected as normally open or normally closed. |
163 |
No Function |
164 |
F/R-Signal /_ |
165 |
F/R-Signal __ |
166 |
General-Alarm /_ |
167 |
General-Alarm __ |
168 |
Max/Min Alarm /_ |
169 |
Max/Min Alarm __ |
170 |
Min Alarm /_ |
171 |
Min Alarm __ |
172 |
Max Alarm /_ |
173 |
Max Alarm __ |
174 |
Empty pipe /_ |
175 |
Empty pipe __ |
176 |
Contact input |
177 |
Selection of the function for the contact input terminals 81/82. |
178 |
No Function |
179 |
Totalizer reset |
180 |
Zero return |
181 |
Iout at Alarm |
182 |
Value of the current during an error condition. |
183 |
High Alarm |
184 |
Low Alarm |
185 |
Detector e.pipe |
186 |
On/Off selection for the operation Detector empty pipe. |
187 |
Off |
188 |
On |
189 |
Alarm e.pipe |
190 |
When the meter tube is empty an indication is displayed and a signal is sent to the terminals when the alarm setting is on. No alarm contact when the Alarm setting is off. |
191 |
Iout at e.pipe |
192 |
Current output value Low or High during an empty pipe condition. |
193 |
0% |
194 |
Simulation Mode |
195 |
Turn flowrate simulation on /off. |
196 |
Test Mode |
197 |
Only for checking the converter with simulator 55XC4000. |
198 |
1st line |
199 |
Selection for the 1st display line. |
200 |
Q [percent] |
201 |
Q [unit] |
202 |
Iout [mA] |
203 |
Q [m/s] |
204 |
Q Bargraph |
205 |
Totalizer |
206 |
Totalizer >F |
207 |
Totalizer <R |
208 |
Totalizer Diff. |
209 |
Tag number |
210 |
Empty pipe |
211 |
Blanks |
212 |
2nd line |
213 |
Selection for the 2nd display line. |
214 |
3rd line |
215 |
Selection for the 3rd display line. |
216 |
4th line |
217 |
Selection for the 4th display line. |
218 |
Operating mode |
219 |
Operating mode Normal: is selected for continuous flow metering. Operating mode Fast: accelerated flow signal processing (e.g. short batches). Operating Mode Piston Pump: for pulsating flows. In this operating mode the improved reproducibility of the flow signal measurements is archieved. The totalizer is automatically set to the Difference Totalizer mode. Any reverse flow which may occur is automatically substracted from the totalizer values. |
220 |
Standard |
221 |
Piston Pump |
222 |
Fast |
223 |
Flow indication |
224 |
Selection of the flow direction to be metered, forward/reverse or forward only. The direction indicator R in the display blinks when flowrate is in the reverse flow direction and 0% is displayed. |
225 |
Forward/Reverse |
226 |
Forward |
227 |
Flow direction |
228 |
Normal/Inverse, reverse the flow direction forward and reverse flow display. |
229 |
Inverse |
230 |
Type of Primary |
231 |
Selection the flowmeter primary type connected to the converter. |
232 |
SE2_,SE4_ |
233 |
DS2_ |
234 |
DS4_ |
235 |
10DS3111(A-C) |
236 |
10DS3111(E- ) |
237 |
10D1422 |
238 |
10D1425 |
239 |
10DS3111 D |
240 |
none |
241 |
Frequency Primary |
242 |
Selects the excitation of primary |
243 |
Primary 70Hz |
244 |
Oldprim. 50 Hz |
245 |
Oldprim. 60 Hz |
246 |
Poll.addr. |
247 |
An adress 0-15 can be selected for instruments with the HART-Protocol. If the adress 0 is entered, then the current output varies as the flowrate in the range of 4-20 mA. If additional instruments are connected to the bus and a adress 1-15 is entered, the converter operates in Multidrop-Mode. The current output is fixed at constant 4mA. The output values are then only can only be read using the HART-Communication. |
248 |
Selection 1 large and 1 small line or 4 small lines. |
249 |
1 big, 1 small |
250 |
4 small |
251 |
Contrast |
252 |
Setting the display contrast, STEP = darker; DATA = lighter. |
253 |
Communication |
254 |
Turn HART -Communication on and off. |
255 |
no Function |
256 |
HART |
257 |
Driver |
258 |
Selects the mode of the driver |
259 |
Regularization |
260 |
Controller |
261 |
The calibrating mode 0 or 255 can be select. With mode 0 the primarys SE2_/SE4_ are calibrated together with converter. The meter size and adjusted value are primary accompanying. At mode 255 the converter can delivered to connect with old primary model, Cs = 100% and Cz = 0% be printed on the FRAM. The customer can select meter size and excitation frequency with ENTER. The EASY SETUP for a old primary must be followed for operation. |
262 |
Line frequency |
263 |
Selection of the line frequency of the flowmeter primary was calibrated. Selection 50/60 Hz only available for Older Models. |
264 |
50 Hz |
265 |
60 Hz |
266 |
Startup Commu. |
267 |
With a TTL-Signal the communication type HART or ASCII can be selected of the service plug for the connection. |
268 |
START-HART-TTL |
269 |
START-ASCII-TTL |
270 |
Function test for the pulse output. |
271 |
Current output |
272 |
Selection of the current output range. For HART-Protocol always 4-20 mA. |
273 |
0-20 mA |
274 |
4-20 mA |
275 |
0-10 mA |
276 |
2-10 mA |
277 |
Com. Type TTL |
278 |
The choice of the occupancy of the communication for the service plug can be returned. Communication HART- TTL or ASCII-TTL can be switched over to on display operate function. |
279 |
HART-TTL |
280 |
ASCII-TTL |
281 |
Display on |
282 |
Pulse (act/pas) |
283 |
Indication of the jumper position for pulse output active or passive. |
284 |
activ |
285 |
passive |
286 |
Actu. Variant |
287 |
The present factory-made for pulse output and communication. it can be identified by the order. |
288 |
Puls active
not Hart |
289 |
Puls active
with Hart |
290 |
Puls passive
not Hart |
291 |
Puls passive
with Hart |
292 |
The status condition of the contact input can be viewed on or off. |
293 |
The test function contact ouput and with ENTER the function can be switched to on or off: |
294 |
EPD Mode |
295 |
Selection of the function standard or new adjustment. At standard is isn't required to carry out a adjustment on side. The converter use standard adjustment datas. If it comes to disturbances through the medium or an empty pipe isn't recognized by the converter, a new adjustment must be carried out on side, see adjustment empty pipe or full pipe. |
296 |
Standard |
297 |
New Adjust |
298 |
self-excitation?? |
299 |
|
300 |
Collection char variables |
301 |
Help char variables |
302 |
device busy |
303 |
prot.cust.trans |
304 |
Overflow counter max. 250. 1 overflow = pulse totalizer 9.999.999 units. Display value is reset and one overflow is counted. |
305 |
5u |
306 |
Mains interrupt |
307 |
Mains interrupt counter. |
308 |
????????????????? |
309 |
Instrument No. |
310 |
Instrument number continuously |
311 |
DAC Amp. |
312 |
Min DAC Amp. |
313 |
Max DAC Amp. |
314 |
Testrig |
315 |
Display Test rig number. |
316 |
DSP Reset |
317 |
Totalization of reset from the DSP electronic. |
318 |
Pg.prot.code |
319 |
When a 0 (factory setting) is entered the program protection is turned off. If a different Progr. Prot. Code has been configured (1-9999), then the operator will be asked for the PP-Code when this level is selected. |
320 |
Overflow D |
321 |
Display of the Overflow counter for the Difference Totalizer. |
322 |
5d |
323 |
col ui_var |
324 |
help unsigned integer variables |
325 |
Cal-fact 10m/s |
326 |
Display of the max. possible flow range. Automatic selection based on the meter size. |
327 |
|
328 |
Qmax |
329 |
Flow range end value for forward and reverse flowrate. Flow range end values can be set between 0.5 and 10 m/s. |
330 |
Pulse factor |
331 |
Pulse factor 0.001 to 1000 pulses per selected unit for the internal and external flow totalization, max. count frequency 5 kHz. The max. count frequency and the pulse factor are checked in the software. If incorrect an error is displayed. |
332 |
Pulse width |
333 |
For external pulse output range pulse width 0.1 to 2000ms. The max. allowable pulse width is checked in the software and corrected if required. |
334 |
ms |
335 |
Low flow cut off |
336 |
Applies to the values displayed and all outputs. The switch point has a built in hysteresis of 0.1%. |
337 |
8.3f |
338 |
6.2f |
339 |
Density |
340 |
Density range 0.1 - 5 g/cm3. Mass flowrate for the display and the totalizer. |
341 |
Unit factor |
342 |
Factor for the configurable flowrate based on liters; factor shown is for kgal units (factory default setting). |
343 |
8.4f |
344 |
Adj. full pipe |
345 |
Display of the adjusted value for a full pipe. The adjustment for the full pipe can be made manually or automatically. |
346 |
Total forward totalizer value. |
347 |
7.4f |
348 |
Total reverse totalizer value. |
349 |
Zero Adjust |
350 |
Flowmeter primary zero value Cz. For Older Models always 0 % |
351 |
Span Adjust |
352 |
Flowmeter primary span value Cs. For Older Models always 100 % |
353 |
Phase |
354 |
Phase between reference and signal voltage. |
355 |
Adjust Iout 4mA |
356 |
Display of the adjusted Iout value for 4.0 mA. |
357 |
Adjust Iout 20mA |
358 |
Display of the adjusted Iout value for 20.0 mA. |
359 |
Channel |
360 |
Span Adjust ->V |
361 |
Span Adjust <-R |
362 |
Channel Adjust |
363 |
Threshold |
364 |
Display of the calculated Threshold value or manually entry. |
365 |
Iout Low Alarm |
366 |
Low Alarm only available for current output 2-10 mA or 4-20 mA. Value of the current output for Low Alarm. |
367 |
Iout High Alarm |
368 |
Value of the current output for High Alarm. If error 3 (flow > 105 %) occurs, the current output is always set to High Alarm |
369 |
Simulation Value |
370 |
The flowrate value displayed can be simulated by pressing STEP or DATA button. The current and pulse outputs follow the simulated flowrate values. |
371 |
??????????? |
372 |
Referencevoltage |
373 |
Delta Amp. |
374 |
Min. Alarm |
375 |
Range limit for the Min. Alarm, range 0-105 % of the selected flow range. Set in 1 % steps, switch hysteresis 1 % |
376 |
.0f |
377 |
Max. Alarm |
378 |
Range limit for the Max. Alarm, range 0-105 % of the selected flow range. Set in 1 % steps, switch hysteresis 1 % |
379 |
Threshold On |
380 |
Threshold Off |
381 |
Output Cycle |
382 |
Input of the time for the indication block of the selected parameter function 0,1-100 s. |
383 |
???????????? |
384 |
Range - Pulse |
385 |
The extended pulse rate for the measurement range up to Qmax. DN. |
386 |
Adj. empty pipe |
387 |
Display of the adjusted value for a empty pipe. The pipeline must be empty. |
388 |
Threshold for turning off empty pipe.This is calculated and typed in internally after adjustment empty pipe or full pipe.The response time is reduced at a manual entry at empty regular measuring pipe at smaller entry values. |
389 |
Collection float variables |
390 |
Help float variables |
391 |
Primary Tag |
392 |
A TAG-Number for the primary can be displayed or enter max. 30-characters. |
393 |
Converter Tag |
394 |
A TAG-Number for the converter can be displayed or enter max. 30-characters. |
395 |
Calib.Date |
396 |
Display Date of the calibration |
397 |
Order-Number |
398 |
Order number of the Instruments |
399 |
Version |
400 |
Tester |
401 |
Units name |
402 |
Four character name for the user configurable units, kgal = factory default setting. |
403 |
Collection string variables |
404 |
Help string variables |
405 |
Collection Reset Functions |
406 |
Help Reset Functions |
407 |
Collection Adjust Functions |
408 |
Help Adjust Functions |
409 |
50s Average |
410 |
After start with ENTER a average flow value is started and shown over 50s |
411 |
Set Totl.forward |
412 |
Set Totl.reverse |
413 |
Set Totl.diff. |
414 |
Reset Totalizer |
415 |
Reset Error regist |
416 |
Reset Conf.changed |
417 |
PS-Code |
418 |
Test Contact outp. |
419 |
no Test Contact output |
420 |
Test Contact input |
421 |
no Test Contact input |
422 |
Test Memory |
423 |
Test Pulse Output |
424 |
Abort Test Pulse Output |
425 |
Test QSimulation |
426 |
Abort Test QSimulation |
427 |
Adj.EPD full pipe |
428 |
Adj.EPD empty pipe |
429 |
Pulse Factor |
430 |
Pulse Width |
431 |
Auto.adj.Sys.zero |
432 |
Collection Memory test Functions |
433 |
Help Memory test Functions |
434 |
upload variables |
435 |
FMU860 |
436 |
DT |
437 |
DVC |
438 |
FCX |
439 |
AS800 |
440 |
340T |
441 |
340C |
442 |
344 |
443 |
Siemens Micro K |
444 |
SITRANS L |
445 |
SIPAN PH |
446 |
SITRANS P |
447 |
75SMT |
448 |
UNIDELTA |
449 |
8320 |
450 |
SX5100 |
451 |
TSV175 |
452 |
DMU |
453 |
3780 |
454 |
BM70 |
455 |
8u |
456 |
4.2f |
457 |
Pulse Output Unit- Engineering units that the frequency andtotalizer outputs will be displayed with. |
458 |
Gross Total Value- Non-resettable totalizer value. Counts frequency output pulses while total control is turned on. This value will be reset to 0 when the pulse scaling, line size, or units are changed. |
459 |
Reverse Total Value- Non-resettable totalizer value. Counts frequency output pulses while total control is turned on and flow is in the reverse direction. This value will be reset to 0 when the pulse scaling, line size, or units are changed. |
460 |
7d |
461 |
Pulse output units- Engineering units that the frequency and totalizer outputs will be displayed with |
462 |
Gross Total Value- Counts frequency output pulses while total control is turned on. This value will be reset to 0 when the pulse scaling, line size, or units are changed |
463 |
Reverse Total Value- Counts frequency output pulses while total control is turned on and flow is in the reverse direction. This value will be reset to 0 when the pulse scaling, line size, or units are changed |
464 |
Pulse output- scaled frequency output from 0-1000 Hz, linear with input. |
465 |
Net Total Value- Resettable totalizer. |
466 |
Totalizer forward |
467 |
write totalizer frw = %{0} ? |
468 |
Totalizer reverse |
469 |
write totalizer rev = %{0} ? |
470 |
Totalizer diff |
471 |
write totalizer diff = %{0} ? |
472 |
Reset all totalizer ? |
473 |
Reset error register and counter mains interrupt? |
474 |
Reset configuration changed flag ? |
475 |
Old PS-Code? |
476 |
uiEingabeAltPS |
477 |
New PS-Code? |
478 |
uiEingabeNeuPS |
479 |
Write new PS-Code? |
480 |
wrong PS-Code |
481 |
Choose from list |
482 |
Toggle Contact out;End |
483 |
Contact output is ON |
484 |
Contact output is OFF |
485 |
contact output is set to actual |
486 |
Test Contact input;End |
487 |
Contact input is ON |
488 |
Contact input is OFF |
489 |
contact input is set to actual |
490 |
Main Fram;Backup Fram;Flash Checksum;End |
491 |
Testing Main Fram |
492 |
Testing Backup Fram |
493 |
Testing Flash Checksum |
494 |
Error: Main Fram |
495 |
Error: Backup Fram |
496 |
Error: Flash Checksum |
497 |
Main Fram: OK |
498 |
Backup Fram: OK |
499 |
Flash Checksum: OK |
500 |
Testvalue Pulse output? |
501 |
Start test pulse output? |
502 |
pulse output is set to %{0} Hz |
503 |
pulse output is set to actual |
504 |
Testvalue QSimulation? |
505 |
Start test QSimulation? |
506 |
QSimulation is set to %{0}%, flow percent value is %{1}% |
507 |
QSimulation is turned off |
508 |
Start adjust empty pipe detector not possible! Please first turn ON Empty Pipe Detector |
509 |
Start adjust detector empty pipe not possible! EPD not in mode New Adjust |
510 |
Start adjust empty pipe detector with full pipe? |
511 |
Adjust full pipe |
512 |
Error Adjust full pipe |
513 |
Adjust full pipe ok. New threshold empty pipe detector %{0} |
514 |
Start adjust empty pipe detector not possible! EPD not in mode New Adjust |
515 |
Start adjust empty pipe detector with empty pipe? |
516 |
Adjust pipe empty |
517 |
Error Adjust pipe empty |
518 |
Adjust empty pipe ok. New threshold empty pipe detector %{0} |
519 |
Send new Pulse factor %{0}/%{1}? |
520 |
Converter changed input. New Pulse factor %{0} |
521 |
Converter changed Pulse width to %{0} ms |
522 |
Send new Pulse width %{0} ms? |
523 |
Converter changed input. New Pulse width %{0} ms |
524 |
Converter changed Pulse factor to %{0} . |
525 |
Start automatic adjust System Zero? |
526 |
Adjust System Zero |
527 |
Error Adjust System Zero |
528 |
Adjust System Zero ok. New System Zero %{0} |