Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
level_sensor_value_unit | 4005 | PV units P12 | PV Units - the units that are displayed with the PV, Ullage and associated readings. | R/W | Enum | 2048 |
level_value | 4006 | Process value D10 | Process value - The digital value based on the height scaled by P13, or profiled by P11 and P13 if the curve profile is non-linear. | R | Float | 34 |
current_output | 4007 | Current output D12 | Current output - The analog value related to the PV | R/W | Float | 66 |
percent_range | 4008 | Percent range D13 | Porcentaje de rango: Variable que rastrea la representación del valor digital con respecto al rango definido por el valor de rango inferior y el valor de rango superior, para modos de funcionamiento normales. Las unidades de esta variable siempre son en porcentaje. | R | Float | 34 |
level_damping_value | 4009 | Smoothing time P20 | Smoothing time - the damping in seconds applied to the PV value and the analogue output. | R/W | Float | 32 |
level_sensor_serial_number | 400A | Sensor ser No P05 | Sensor serial number - usually set to the same value as the Device ID but may be changed for site use. | R/W | Unsigned | 2048 |
level_sensor_units | 400D | R/W | Unsigned | 2048 | ||
level_upper_range_value | 400B | Calibrate max P15 | Calibrate max - the PV at which the current output is 20mA and the % output is 100%. | R/W | Float | 32 |
level_lower_range_value | 400C | Calibrate min P16 | Calibrate min - the PV at which the current output is 4mA and the % output is 0%. | R/W | Float | 32 |
alarm_code | 4010 | AO Alrm typ | R | Enum | 2048 | |
Name | ID | Label | Description | Type | Access | Class |