Loading…

Variable Name: level_damping_value

Variable ID: 0x4009

Variable Label: Smoothing time P20

Variable Help: Smoothing time - the damping in seconds applied to the PV value and the analogue output.

Variable Handling: R/W

Variable Class: InputBlock

Variable Size: 4

Variable DataType: Float

Variable Display Format: |en|4.1f

Variable Edit Format: |en|4.1f

Variable Unit:

Variable Max: 1000

Variable Min: 0

Variable Read Command List

Command Number Command ID Command Name
15 00B7 read_pv_output_info

Variable Write Command List

Command Number Command ID Command Name
34 0FA6 write_pv_damping_value