名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
input_volt_digital_units | 4343 | Input voltage unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. | 读 | 枚举 | 32 |
input_volt_digital_value | 4344 | Input voltage | 读 | 浮点 | 10 | |
discrete_action_code | 4345 | Discrete Action | Selects an action to be assigned to a discrete. | 读/写 | 枚举 | 4096 |
discrete_assignment_code | 4346 | Discrete Assignment | Assigns a discrete to an action. Select none for no discrete assignment. | 读/写 | 枚举 | 4096 |
live_zero_vol_flow_digital_units | 4347 | Live Zero unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. | 读/写 | 枚举 | 32 |
live_zero_vol_flow_digital_value | 4348 | Live Zero | 读 | 浮点 | 10 | |
live_zero_vol_flow_digital_cutoff | 4349 | 质量流量切除 | The volume flow rate below which the frequency/pulse output indicates zero flow, and below which totalizers stop counting. | 读/写 | 浮点 | 8 |
live_zero_vol_flow_analog_value | 434A | 质量流量模拟值 | 读/写 | 浮点 | 66 | |
live_zero_vol_flow_analog_upper_limit | 434B | 模拟量上限 | 模拟量输出上端点值——定义正常工作条件下每个模拟量输出的上端点。 | 读 | 浮点 | 64 |
live_zero_vol_flow_analog_lower_limit | 434C | 模拟量下限 | 模拟量输出下端点值——定义正常工作条件下每个模拟量输出的下端点。 | 读 | 浮点 | 64 |