名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
operatingMode | 0870 | 操作模式1 | 特定现场设备操作模式1——现场设备中一种可能的操作模式。 | 读 | 枚举 | 2049 |
extended_fld_device_status | 0807 | Extended Device Status | Provides additional Device Status information | 读 | 位枚举 | 0 |
serial_number | 4008 | 传感器序列号 | 传感器序列号——识别数值表示或现场设备变量来源的传感器。 | 读/写 | 无符号 | 2048 |
met_direct | 4009 | 流向 | This parameter enables the user to determine whether the outputs and totalizers will indicate forward, reverse, bi-directional or absolute value flow. | 读/写 | 枚举 | 32 |
output_opt_brd | 400A | Output Opt. Brd. | This parameter represents the various types of output option boards that are available. | 读 | 枚举 | 2048 |
totctl | 400B | 累加器控制 | Allows the user to Reset, Stop, or Start all totalizers. NOTE - Inventory totals are NOT reset. | 读/写 | 枚举 | 4096 |
mass_flow_digital_units | 400C | 质量流量单位 | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. | 读/写 | 枚举 | 32 |
mass_flow_digital_value | 400E | Mass flo | 读 | 浮点 | 10 | |
mass_flow_digital_cutoff | 4010 | 质量流量切除 | The mass flow rate below which the frequency/pulse output indicates zero flow, and below which totalizers stop counting. Cutoffs can also be configured for the mA output(s) (the AO cutoffs). An AO cutoff is active only if the process variable assigned to the output is mass flow or volume flow. | 读/写 | 浮点 | 8 |
mass_flow_analog_value | 4011 | 质量流量模拟值 | 读/写 | 浮点 | 66 | |
名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |