名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
gas_vol_flow_hzrate | 4316 | 速率系数 | The flow rate that equals a set frequency if the frequency output represents mass or volume flow; or the mass or volume total that equals a set number of pulses if the frequency output represents mass or volume total. | 读/写 | 浮点 | 512 |
gas_vol_flow_p_u | 4317 | Pulses/Unit | This parameter allows you to scale the frequency output in terms of the number of pulses per unit of flow. | 读/写 | 浮点 | 512 |
gas_vol_flow_u_p | 4318 | Units/Pulse | This parameter allows you to scale the frequency output in terms of the number of units of flow required to generate one pulse. | 读/写 | 浮点 | 512 |
gas_std_vtot_digital_units | 4319 | Gas Vol flo tot inv unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. | 读 | 枚举 | 32 |
gas_std_vtot_digital_value | 431A | Gas Vol totl | 读 | 浮点 | 10 | |
gas_std_vinv_digital_units | 431B | 总体积流量单位 | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. | 读 | 枚举 | 32 |
gas_std_vinv_digital_value | 431C | Gas Vol inventory | 读 | 浮点 | 10 | |
cust_trans_totalizer_reset | 431D | Custody trf. tot reset opt | Custody transfer totalizer reset options | 读/写 | 枚举 | 32 |
factory_zero_offset | 431E | Factory zero offset | Factory zero offset value - always microseconds. | 读/写 | 浮点 | 10 |
pc_index | 433A | Discrete Event num | 读/写 | 索引 | 4096 | |
名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |