Name ID Label Description Type Access Class
Word_422 42F8 Status Word 422 Reads Modbus register no. 422 R BitEnum 10
Word_421 42F9 Status Word 421 Reads Modbus register no. 421 R BitEnum 10
Word_424 42FA Status Word 424 Reads Modbus register no. 424 R BitEnum 10
Word_423 42FB Status Word 423 Reads Modbus register no. 423 R BitEnum 10
Word_433 42FC Status Word 433 Reads Modbus register no. 433 R BitEnum 10
Word_434 42FD Status Word 434 Reads Modbus register no. 434 R BitEnum 10
flow_switch_setpoint 42FE Flow Switch Setpoint This parameter can be used to trigger a discrete output when the mass flow rate exceeds the configured setpoint. There is a fixed hysteresis of 5% for this setpoint. R/W Float 16
feature_key 42FF Features The type of log to be reset. R BitEnum 2048
ETO_number 4300 ETO Number Engineered to Order (ETO) number for the transmitter R Unsigned 2048
World_area_weights_measures_security 4301 World Area for Weights and Measures Security Displays World Area for Weights and Measures Security R Enum 2048
Name ID Label Description Type Access Class