Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
poll_var_1 | 4114 | Polled Var 1 | This represents the variable code which will be read via HART for the compensation. | R/W | Enum | 128 |
poll_var_2 | 4115 | Polled Var 2 | This represents the variable code which will be read via HART for the compensation. | R/W | Enum | 128 |
poll_type_code | 4116 | Polling Type | This parameter identifies which compensation algorithms will be enabled within the device based on the polling being done. | R/W | Enum | 128 |
flow_pres_factor | 4117 | Flow factr | Pressure compensation factor applied to flow rate (% change per PSI). | R/W | Float | 8 |
dens_pres_factor | 4118 | Dens factr | Pressure compensation factor applied to density (g/Cucm change per PSI). | R/W | Float | 8 |
zero_pres_factor | 4119 | Flowcal pressure | Pressure at which flow calibration was performed. | R/W | Float | 8 |
enable_pres_comp | 411A | Enable Pressure Comp | This parameter allows you to enable/disable the pressure correction feature | R/W | Enum | 8 |
static_pressure | 411B | Static Pressure | This parameter allows you to enter a static pressure when using the pressure correction feature | R/W | Float | 8 |
enable_extern_temp | 411C | Enable Ext Temp | This parameter allows you to enable/disable the external temperature feature | R/W | Enum | 8 |
static_temperature | 411D | Static Temperature | This parameter allows you to enter a static temperature when using the external temperature feature | R/W | Float | 8 |
Name | ID | Label | Description | Type | Access | Class |