Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
hpFreq | 421F | HP Filter | Setting of the low distance filter. Signals below the programmed distance (referred to the flange) are reduced, the more the nearer they are to the instrument. The filter can be set in order to suppress disturbances from antenna extensions or near reflection signals. Acceptable input range: 0 - 5.0 m (BM 702: 0/0.5/1/2 m) Default value: set by manufacturer Not available for BM 700. (SEr. 4.1.3) | R/W | Enum | 8 |
espFunc | 40B8 | Empty spectrum | Under this function the empty spectrum is activated or deactivated. To record and store new empty spectrum, invoke the "Record tank empty spectrum"-method from the Device Context menu. You can then choose between: · OFF: The empty spectrum is not considered for measurements but remains stored in the BM 70 A/P /700/702 and can be activated again at a later date. · ON: The empty spectrum is (again) activated and considered for measurements. · RECORD: The previous empty spectrum is to be deleted and a new one recorded. (Fct. 3.5.2) | R/W | Enum | 8 |
pipeEna | 40B9 | Stillwell | If the device is operated with a still well, the option Still well = YES and the inside diameter of the pipe should be entered. · NO : operation without still well · YES : peration with still well (Fct. 3.1.6) | R/W | Enum | 8 |
dinFunc | 40BA | Fct digital input | The function of the digital input (only in instruments with Ex-e current output HART ®) can be selected for freezing the measured value or warmstarting the BM 70 A/P or it can be switched off (functionless). Selection: OFF, FREEZE, WARMSTART Default value: "Freeze" Not available for BM 700/702. (SEr. 4.2.4) | R/W | Enum | 2052 |
ftbFunc | 40BB | Function FTB | The tank bottom tracing system (see Sect. 8.6.15 of 'Operating Manual') is activated under this function: · OFF The FTB is deactivated; the device operates in the standard mode. · PARTIAL When this option has been selected, the tank bottom tracing system is activated only in the vicinity of the tank bottom, i.e. at low levels (max. 20% of the tank height but a minimum of 0.6 m). Given higher levels, the normal measuring method is used (reflection from the product surface). This method is sufficient for most applications with poorly reflecting products. The parameter "Epsilon R" must be as exact as possible. · FULL (for BM 70 A only) When this option is selected, the tank bottom tracing system is activated over the total measuring range (tank height). For tank heights above 16 m, however, measuring accuracy is additionally affected. The parameter "Epsilon R" must be as exact as possible. (Fct. 3.5.7) | R/W | Enum | 2048 |
notUsed2 | 40BC | Dummy | R/W | Unsigned | 8 | |
espRec | 40BD | Empty spect. type | R/W | Enum | 8 | |
relFunc | 40BE | Function S | The functions for the switching output can be applied to: a) the additional switching output in the Version "Ex-e or Ex-i current output HART ®", or b) the current output if "Function I" is set to "SW Output S". Switching output not available for BM 700/702. Use this function to select the measured variable. (Fct. 3.6.1) | R/W | Enum | 2049 |
relLimit | 40BF | Type S | Use this function to set the type of switching output: · HIGH (= contact closes when upper limit of threshold + hysteresis/2 exceeded) · LOW (= contact closes when lower limit of threshold - hysteresis/2 exceeded) (Fct. 3.6.2) | R/W | Enum | 2048 |
sioMode | 40C0 | Protocol | R/W | Enum | 2048 | |
Name | ID | Label | Description | Type | Access | Class |