Name ID Label Description Type Access Class
xmtr_specific_status_4 0FB9 Status group 5 Field Device Specific Status Byte 5- Data that has Field Device status information relating to: failures / warnings / status of process's. R BitEnum 2051
xmtr_specific_status_5 0FBA Status group 6 Field Device Specific Status Byte 6- Data that has Field Device status information relating to: failures / warnings / status of process's. R BitEnum 2051
transmitter_variable_code_1 0FA0 Index into Dynamic Variables Array- Is the first an array of addresses, whose value is identified by the Field Device Variable Code R/W Index 4096
transmitter_variable_code_2 0FA2 Index into Dynamic Variables Array- Is the second of an array of addresses, whose value identified by the Field Device Variable Code R/W Index 4096
transmitter_variable_code_3 0FA3 Index into Dynamic Variables Array- Is the third of an array of addresses, whose value identified by the Field Device Variable Code R/W Index 4096
transmitter_variable_code_4 0FA4 Index into Dynamic Variables Array- Is the fourth of an array of addresses, whose value identified by the Field Device Variable Code R/W Index 4096
flow_alarm_select 1F83 AO Alrm typ Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. R/W Enum 64
flow_analog_value 1F7D AO1 Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes R/W Float 66
flow_damping_value 1F87 PV Damp Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 32
flow_lower_range_value 1F86 PV LRV Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
flow_lower_sensor_limit 1F80 PV LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R/W Float 8
flow_minimum_span 1F81 PV Min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R/W Float 32
flow_percent_range 1F7E PV % rnge Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R/W Float 34
flow_range_units 1F88 PV rnge unit Range Unit- Engineering unit to be displayed with the Upper Range Value and Lower Range Value R/W Enum 32
flow_sensor_serial_number 1F82 PV Snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R/W Unsigned 2048
flow_units 1F7B PV unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 32
flow_upper_range_value 1F85 PV URV Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
flow_upper_sensor_limit 1F7F PV USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R/W Float 8
flow_value 1F7C PV Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention R/W Float 34
pulse_width_value 1F50 Puls width Pulse Width- Width of the frequency output pulse on frequency output number 'X'. R/W Integer 512
units_code 07E9 R/W Enum 4096
transfer_function 1F84 Xfer fnctn Transfer Function- Defines the transformation function that will be applied from the Field Device Variable to the Analog Output, and Percent Range. The Transfer Function does not affect the Digital Value representation. R Enum 64
Name ID Label Description Type Access Class