Variable Name: media_range

Variable ID: 0x4031

Variable Label: Media Range

Variable Help: MEDIA RANGE is the net distance from the Laser face to the maximum application range (example: max distance from laser face to silo bottom). This value must be entered in units that correspond to the unit of the process variable. The max available range on SS140XP is 262 ft / 80m for level measurement to any natural target.

Variable Handling: R/W

Variable Class: Device

Variable Size: 4

Variable DataType: Float

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: 99999

Variable Min: 0

Variable Read Command List

Command Number Command ID Command Name
158 4030 read_basic_device_setup

Variable Write Command List

Command Number Command ID Command Name
159 4035 write_media_range