Loading…
Loading…
Variable Name: media_range
Variable ID: 0x4031
Variable Label: Media Range
Variable Help: MEDIA RANGE is the net distance from the Laser face to the maximum application range (example: max distance from laser face to silo bottom). This value must be entered in units that correspond to the unit of the process variable. The max available range on SS140XP is 262 ft / 80m for level measurement to any natural target.
Variable Handling: R/W
Variable Class: Device
Variable Size: 4
Variable DataType: Float
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max: 99999
Variable Min: 0
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
158 | 4030 | read_basic_device_setup |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
159 | 4035 | write_media_range |