Loading…

变量名称: CO_OperatingMode_1

变量ID: 0x4059

变量标签: Current range output

变量描述: Select the current range for the measured value output and the upper and lower fault condition signal level. Additional information: - The measured value range is specified in the "Lower range value output @1" parameter and the "Upper range value output @1" parameter. - If the measured value lies outside the scaled measured value range, diagnostic message "441 Current output @1 faulty" is generated. - In the event of a device alarm, the current output adopts the behavior specified in the "Failure behavior current output @1" parameter.

变量处理: 读/写

变量分类: 设备

变量长度: 2

变量数据类型: 枚举

变量枚举值 变量枚举文本
0x800C 4...20 mA NE (3.8...20.5 mA)
0x800D 4...20 mA US (3.9...20.8 mA)
0x800A 4...20 mA (4... 20.5 mA)
0x8088 Fixed value

变量显示格式:

变量编辑格式:

变量单位:

变量最大值: N/A

变量最小值: N/A

变量读取命令列表

命令号 命令ID 命令名称
173 42E8 read_index_parameter_173

变量写入命令列表

命令号 命令ID 命令名称
178 42E6 write_index_parameter_178