- * Copyright (c) 2004, Siemens, All Rights Reserved
- *****************************************************************************
- *
- * Description: Device Description Language Manufacturer Specific Dictionary
- *
- Design Note- This version of the standard dictionary uses
- the new, 2 letter language codes. It must be used with
- the new Phase 2 tokenizer and linker.
- Note: Like in the standard dictionary, do not use the code for England |en|.
- The AMS software otherwise could not display the labels.
- Design Note- File conforms to the ISO Latin1 character set. Make sure editors
- conform to this standard!
- Design Note- unix2dos and dos2unix will destroy some of the special characters
- unless the -ascii option is used!
- Design Note- To inject delimiter characters put a back slash before
- the character (Ex. \").
- Design Note- Lines should be limited to less than 255 characters. To continue a line,
- end the line with a '"' character and start the following line with another
- '"' character.
- Design Note- If there are more than two string handles with the exact same name
- only the first one will be found by the tools.
- Design Note- A String reference must not begin with a number.
- Design Note- An APPHELP with the words 'Translation Pending' (e.g. APPHELP "|de|Translation Pending")
- means that a translation is forthcomming. Therefore, if this string is used in a DD,
- then the DD Developer is responsible for whatever the translation becomes in the future.
- General guidelines using the Siemens dictionary
- 1. Siemens may have one and only one supplemental standard dictionary.
- 2. The string numbers for Siemens devices begin at 10000 + 100 x manufacturer ID. (10000 + 100 x 42 = 14200)
- The maximum number of different sections is limited to 100. The number of strings per section is unlimited.
- This means that Siemens can use the sections in the range from 14200 to 14299.
- 3. A string may not be modified or removed once the dictionary is registered. It is only allowed to add
- new strings to the dictionary.
- 4. A supplemental standard dictionary will be treated as a new DD. The fees are $2000 for the registration of the
- initial revision and $500 for each succeeding revision update.
- 5. Use the -s option with the pre-tokenizer for tokenization.
- (example: hcfpretok.exe -s siemens.dct)
- 6. Use the -d option with the 275 linker newlink.exe.
- (example: newlink -p -d hc.dct -d siemens.dct -b 0 -c link.cfg -o pclink.out -e link.err)