Method Name: DS_Method_SILActivate_1
Method ID: 0x4168
Method Label: Increased safety mode
Method Help:
- {
- _set_device_status(0xFF,0);
- _set_all_resp_code(0);
- _set_xmtr_device_status(0xFF,0);
- _add_abort_method(17113);
- _iassign(17114,0);
- _iassign(17052,10020);
- send_command(172);
- readParameterWithCMD170(0x0025);
- readParameterWithCMD170(0x001B);
- readParameterWithCMD170(0x002C);
- readParameterWithCMD170(0x306D);
- do {
- if (_ivar_value(17116) == 2)
- {
- _iassign(17052,11040);
- _iassign(17116,0);
- process_abort();
- }
Please login for more