Loading…

Method Name: TRJ_Method_ResetDevTempMinMax_1

Method ID: 0x41B2

Method Label: Reset device temp. min/max values

Method Help: Reset min/max- values of electronic temperature to their default values.


  • {
  • _set_device_status(0xFF,0);
  • _set_all_resp_code(0);
  • _set_xmtr_device_status(0xFF,0);
  • _set_xmtr_all_resp_code(0);
  • _iassign(16449,(1));
  • _iassign(16493,(0x2000)); send_command(171);;
  • send_command(186);


Please login for more