方法名称: Set_Probe_End_Threshold_Gain

方法ID: 0x4106

方法标签: Probe End Threshold

方法描述: This function enables distinction between disturbances in the measurement signal and the actual probe end signal.


  • {
  • char status[3];
  • long ids[1];
  • char loop;
  • float amplitude_range_h;
  • float amplitude_range_l;
  • float amplitude1;
  • float amplitude2;
  • int gain1;
  • int gain2;
  • int gain_range_l;
  • int gain_range_h;
  • _iassign(16538,0x04);
  • _iassign(16539,0x01);
  • _set_device_status(0xFF,0);
  • _set_xmtr_device_status(0xFF,0);
  • send_trans(132,141,status);
  • if (status[0])
  • {