方法名称: methodManualStop
方法ID: 0x4025
方法标签: Manual Stops
方法描述: This method is used to set manual stops.
- {
- char nbr;
- char status[3];
- char prevMode;
- int result;
- send(249, status); if( status[0] != 0 ) { display_response_status(249, status[0]); DELAY(3,"|en|Procedure aborted \nTry Again."); process_abort();; }; if( (_ivar_value(16385) != 0) ) { ACKNOWLEDGE("|en|WARNING. This procedure requires to enter setup mode and will result in LOSS of PROCESS CONTROL. Do you wish to proceed ?"); PUT_MESSAGE("|en|Changing mode to Setup"); _add_abort_method(16390); _iassign(16684,(0)); send(135, status); if( status[0] != 0 ) { display_response_status(135, status[0]); DELAY(3,"|en|Procedure aborted \nTry Again."); process_abort();; }; nbr=0; do { nbr += 1; if( nbr == 10 ) { DELAY(3,"|en|Procedure aborted \nTry Again."); process_abort();; }; send(249, status); } while( _ivar_value(16385) != 0 ); };
- ACKNOWLEDGE("|en|WARNING. This procedure will MOVE the valve. This will result in LOSS of process CONTROL. DO YOU WISH TO CONTINUE?");
- do
- {
- result = SELECT_FROM_LIST("|en|Set Manual Stop Position:",
- "|en|Low;High;Exit");
- if (result != 2)
- {
- _iassign(16683,(3));
- if( ((result == 1) && (_ivar_value(16414) == 0)) ||
- ((result == 0) && (_ivar_value(16414) == 1)) )