Loading…

Method Name: analog_in_calib_method

Method ID: 0x4330

Method Label: Analog Input

Method Help: Follow the prompts to calibrate the instrument analog input sensor.


  • {
  • float qa;
  • float qb;
  • float qc;
  • float qd;
  • float qe;
  • float mpp;
  • int q;
  • int q0;
  • int q1;
  • int q2;
  • int q3;
  • int q4;
  • int q5;
  • int q6;
  • int q7;
  • int q8;
  • char S[3];
  • int b;
  • int c;
  • int n;
  • int user_input;
  • unsigned int i;
  • long ids[2];
  • float t;
  • float d;
  • _set_device_status(0xFF,0);
  • _set_xmtr_device_status(0xFF,0);
  • _set_all_resp_code(1);
  • _set_resp_code(8,0);
  • send(151,S);
  • if (_ivar_value(16804) > 2)
  • {
  • ACKNOWLEDGE(literal_string(2015));
  • return;
  • }
  • ;
  • send(138,S);
  • if ((_ivar_value(16791) & 0x80) > 0)
  • {
  • ACKNOWLEDGE(literal_string(2448));
  • return;
  • }
  • ;
  • if (1 == _ivar_value(167))
  • {
  • ACKNOWLEDGE(literal_string(2274));
  • process_abort();
  • }
  • user_input = SELECT_FROM_LIST(literal_string(2411),literal_string(2226));
  • if (0 == user_input)
  • {
  • send_trans(129,0,S);
  • _vassign(16452,16427);
  • save_values();
  • if (1 == _ivar_value(167))
  • {
  • ACKNOWLEDGE(literal_string(2274));
  • process_abort();
  • }
  • if (_ivar_value(16427))
  • {
  • if ((_ivar_value(16465) & 0x01C0) == 0x0100)
  • {
  • _get_dev_var_value(literal_string(2275),0,16452);
  • }
  • else
  • {
  • _get_dev_var_value(literal_string(2276),0,16452);
  • }
  • save_values();
  • if (_ivar_value(16452) > 0)
  • {
  • ACKNOWLEDGE(literal_string(2277));
  • process_abort();
  • }
  • else
  • {
  • send_trans(130,6,S);
  • }
  • }
  • send_trans(129,0,S);
  • if (1 == _ivar_value(16472) || 5 == _ivar_value(16472))
  • {
  • if (1 == _ivar_value(16472))
  • {
  • ACKNOWLEDGE(literal_string(2256));
  • }
  • else
  • {
  • ACKNOWLEDGE(literal_string(2257));
  • }
  • process_abort();
  • }


Please login for more