Method Name: PST_enable_method

Method ID: 0x4346

Method Label: Change PST Enable

Method Help:


  • {
  • int i, j;
  • long ids[2];
  • float tr, fRoundingFactor;
  • float qa, qb, qc, qd, qe; int q, q0, q1, q2, q3; char S[3];
  • _set_device_status(0xFF,0);
  • _set_xmtr_device_status(0xFF,0);
  • _set_all_resp_code(1);
  • _set_resp_code((8),0);
  • send(151,S); if(_ivar_value(16804) > 1) { ACKNOWLEDGE("|en|The DD revision is not compatible with the firmware in the device.\nContact your Fisher sales office for an upgrade to your Device Description."); return; };
  • if(((_ivar_value(16465) & 0x0100) != 0x0100))
  • {
  • ACKNOWLEDGE("|en|This Instrument Level does not support this procedure.");
  • process_abort();
  • }
  • if(((_ivar_value(16465) & 0x01C0) == 0x0100))
  • {


Please login for more