Method Name: FieldCommunicator_CalibrationSequenceSequenceMethod_97637_97749_1

Method ID: 0x47F1

Method Label: Wizard

Method Help:


  • {
  • int varid[1];
  • int step;
  • int write;
  • int tempconfirm;
  • int select;
  • long temp;
  • _set_all_resp_code(0);
  • _set_device_status(0xFF,0);
  • step = 0;
  • write = 1;
  • do {
  • switch (step)
  • {
  • case 0:
  • step = 0 + 1;
  • if (STD_UserLevel_1 == 33064 || STD_UserLevel_1 == 32807 || STD_UserLevel_1 == 32791)
  • {
  • write = 1;
  • }
  • else
  • {
  • write = 0;
  • }
  • _get_dev_var_value(literal_string(32),0,16695);
  • if (write == 1)
  • {
  • send_command_trans(166,1869);
  • send_command_trans(159,107);
  • }
  • break;
  • case 1:
  • step = 1 + 1;
  • if (STD_UserLevel_1 == 33064 || STD_UserLevel_1 == 32807 || STD_UserLevel_1 == 32791)


Please login for more