Method Name: do_reset_trip_alarm

Method ID: 0x40CE

Method Label: reset trip alarm meter

Method Help:


  • {
  • char status[20];
  • int commn1;
  • commn1 = 194;
  • ACKNOWLEDGE(literal_string(817));
  • trip_alarm_clr = 0xfffffffffffffffe;
  • send_trans(commn1,4,status);
  • DELAY(1,literal_string(71));
  • if (status[0])
  • {
  • display_response_status(commn1,status[0]);
  • }
  • else
  • {
  • send_trans(193,4,status);
  • DELAY(2,literal_string(804));
  • }