Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
self_test | 41C4 | Self test | Self Test- Commands the ZR402 electronics to perform a selftest. Reports any errors that occured. | msrc_UNKNOWN | Details |
master_test | 41C5 | Master test | Master Reset- Commands the ZR402 electronics to reset and perform a selftest. Reports any errors that occured. | msrc_UNKNOWN | Details |
config_model | 41C6 | Configration | msrc_UNKNOWN | Details | |
abort_config_model | 41C7 | msrc_UNKNOWN | Details | ||
set_primary_variable | 41C8 | PV is | Primary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Primary Variable dynamic variable | msrc_UNKNOWN | Details |
set_secondary_variable | 41C9 | SV is | Secondary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Secondary Variable dynamic variable | msrc_UNKNOWN | Details |
set_tertiary_variable | 41CA | TV is | Tertiary Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Tertiary Variable dynamic variable | msrc_UNKNOWN | Details |
set_fourth_variable | 41CB | 4V is | Fourth Index into Dynamic Variables Array- An index location, that indicates which Field Device dynamic variable has been mapped into the Fourth Variable dynamic variable | msrc_UNKNOWN | Details |
test_contact_output | 41CC | Test DO | msrc_UNKNOWN | Details | |
test_calib_cont_output | 41CE | Test Cal. DO | Test calibration DO(zero gas & span gas) | msrc_UNKNOWN | Details |
abort_do_test | 41CD | msrc_UNKNOWN | Details | ||
abort_calib_do_test | 41CF | msrc_UNKNOWN | Details | ||
manual_calibration | 41D0 | Manual calib. | Manual calibaration | msrc_UNKNOWN | Details |
abort_manual_calibration | 41D1 | Abort maual calibration | msrc_UNKNOWN | Details | |
start_semi_auto_calibration | 41D2 | Semi-auto calib. | Start semi-auto calibaration | msrc_UNKNOWN | Details |
abort_calibration | 41D3 | Abort calib. | msrc_UNKNOWN | Details | |
start_blow_back | 41D4 | Start blow back | msrc_UNKNOWN | Details | |
abort_blow_back | 41D5 | Abort blow back | msrc_UNKNOWN | Details | |
oxygen_max_vars | 41D6 | Max oxygen is | msrc_UNKNOWN | Details | |
oxygen_min_vars | 41D7 | Min oxygen is | msrc_UNKNOWN | Details | |
humidity_max_vars | 41D8 | Max humidity is | msrc_UNKNOWN | Details | |
humidity_min_vars | 41D9 | Min humidity is | msrc_UNKNOWN | Details | |
mixing_max_vars | 41DA | Max mixing is | msrc_UNKNOWN | Details | |
mixing_min_vars | 41DB | Min mixing is | msrc_UNKNOWN | Details | |
calib_const_log | 41DC | Calib. log | msrc_UNKNOWN | Details | |
read_date_time | 41DD | Read date&time | msrc_UNKNOWN | Details | |
write_date_time | 41DE | Write date&time | msrc_UNKNOWN | Details | |
calibration_purge_time | 41DF | Purge time | msrc_UNKNOWN | Details | |
calibration_time | 41E0 | Calibration time | msrc_UNKNOWN | Details | |
auto_calibration_data | 41E1 | Auto calib. timing | msrc_UNKNOWN | Details | |
blow_back_purge_time | 41E2 | Blow purge time | msrc_UNKNOWN | Details | |
blow_back_time | 41E3 | Blow back time | msrc_UNKNOWN | Details | |
auto_blow_back_data | 41E4 | Auto blow timing | msrc_UNKNOWN | Details | |
write_enable_10min | 41E5 | Enable wrt 10min | msrc_UNKNOWN | Details | |
change_to_new_password | 41E7 | New password | msrc_UNKNOWN | Details | |
err_abort_without_func_key_disp | 41E6 | Aborting | msrc_UNKNOWN | Details | |
normal_exit_for_chg_passwd | 41E8 | Exiting | msrc_UNKNOWN | Details | |
analog_dac_trim | 100A | Trim analog output | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
fixed_analog_output | 1008 | Fix analog output | Fix Analog Output- Allows the User to manually manipulate a selected Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
leave_analog_fixed_current_mode | 1009 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the selected Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output then tracks the input | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
Name | ID | Label | Description | Type | Source |