Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
ejx_method_chg_pwon_info | 41BB | Chg power on info | Chg power on info- Change the information displayed when turn on the power. | msrc_UNKNOWN | Details |
display_power_on_info | 41BD | Abort of the Chg power on info | Abort of the Chg power on info- Display the power on information. | msrc_UNKNOWN | Details |
ejx_method_chg_univ_rev | 41BA | Chg universal rev | Chg universal rev- Change the universal command revision. | msrc_UNKNOWN | Details |
display_universal_rev_j | 41BF | Abort of the Chg universal rev | Abort of the Chg universal rev- Display the universal revision. | msrc_UNKNOWN | Details |
display_universal_rev_j_var | 41BE | Abort of the Chg universal rev | Abort of the Chg universal rev- Display the universal revision. | msrc_UNKNOWN | Details |
ejx_method_self_test | 4016 | Auto teste | Self Test- Commands the EJX electronics to perform a selftest. Reports any errors that occured. | msrc_UNKNOWN | Details |
ejx_method_self_test_exp_1 | 41A6 | msrc_UNKNOWN | Details | ||
ejx_method_master_test | 4017 | Teste mestre | Master Reset- Commands the EJX electronics to reset and perform a selftest. Reports any errors that occured. | msrc_UNKNOWN | Details |
ejx_method_master_test_exp_1 | 41A7 | msrc_UNKNOWN | Details | ||
ejx_method_clear_dac_trim | 40D6 | Clear D/A trim | msrc_UNKNOWN | Details | |
ejx_method_set_diag_mode | 419E | Set Diag Mode | msrc_UNKNOWN | Details | |
ejx_method_error_log_view | 40DD | Error log view | msrc_UNKNOWN | Details | |
ejx_method_error_log_clear | 40DE | Error log Clear | msrc_UNKNOWN | Details | |
ejx_method_perform_write_atm_pres_value | 40DF | Auto Atm. Pres | msrc_UNKNOWN | Details | |
ejx_method_set_base_unit | 40E2 | Set Base Unit | msrc_UNKNOWN | Details | |
ejx_method_modify_unit | 40E3 | Modify Unit | msrc_UNKNOWN | Details | |
ejx_method_do_test | 40E9 | DO Test | msrc_UNKNOWN | Details | |
ejx_method_set_engr_unit | 40ED | Set Engr Unit | msrc_UNKNOWN | Details | |
ejx_method_modify_engr_unit | 40EE | Modify Engr Unit | msrc_UNKNOWN | Details | |
ejx_method_test_key | 4023 | Test Key | msrc_UNKNOWN | Details | |
ejx_method_write_enable_10min | 40F0 | Enable wrt 10min | msrc_UNKNOWN | Details | |
ejx_method_change_to_new_password | 40F1 | New password | msrc_UNKNOWN | Details | |
ejx_method_after_do_test | 40F2 | After DO Test | msrc_UNKNOWN | Details | |
err_abort_without_func_key_disp | 40F3 | Aborting | msrc_UNKNOWN | Details | |
normal_exit_for_chg_passwd | 40F4 | Exiting | msrc_UNKNOWN | Details | |
ejx_method_chk_supported_device | 41BC | msrc_UNKNOWN | Details | ||
ejx_method_change_pv_assign | 40D2 | Change PV Assgn | msrc_UNKNOWN | Details | |
ejx_method_change_sv_assign | 40D3 | Change SV Assgn | msrc_UNKNOWN | Details | |
ejx_method_change_tv_assign | 40D4 | Change TV Assgn | msrc_UNKNOWN | Details | |
ejx_method_change_qv_assign | 40D5 | Change QV Assgn | msrc_UNKNOWN | Details | |
ejx_method_scaled_dac_trim | 41CE | Ajuste escalonado D/A | Digital para ajuste analógico escalado- Permite a calibração da saída analógica selecionada com uma referência externa nos endpoints de operação da saída analógica | msrc_UNKNOWN | Details |
ejx_method_pres_trim | 40D7 | Pres trim | msrc_UNKNOWN | Details | |
ejx_method_clear_pres_sensor_trim | 40D8 | Clear P trim | msrc_UNKNOWN | Details | |
ejx_method_sp_trim | 40D9 | SP trim | msrc_UNKNOWN | Details | |
ejx_method_clear_sp_sensor_trim | 40DA | Clear SP trim | msrc_UNKNOWN | Details | |
ejx_method_et_trim | 40DB | ET trim | msrc_UNKNOWN | Details | |
ejx_method_clear_et_trim | 40DC | Clear ET trim | msrc_UNKNOWN | Details | |
ejx_method_burst_device_variables | 41CF | Burst Xmtr Vals | msrc_UNKNOWN | Details | |
ejx_method_simulate | 41CD | Simulate | Simulate. | msrc_UNKNOWN | Details |
ejx_method_reset_configuration_change_flag | 41CC | Reset cfg chng flag | Reset configuration changed flag. | msrc_UNKNOWN | Details |
ejx_method_acknowledge_event_notification | 41D1 | Acknowledge Event Notification | msrc_UNKNOWN | Details | |
transmitter_loop_test | 1023 | Teste de malha | Teste de malha- Permite o usuário a manipular manualemnte a saída analógica para o valor de saída de constante selecionada | msrc_UNKNOWN | Details |
transmitter_dac_trim | 1024 | Ajuste D/A | Digital para ajuste analógico- Permite a calibração da saída analógica selecionada com uma referência externa nos endpoints de operação da saída analógica | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Abortar retorno para normal | msrc_UNKNOWN | Details | |
warning_message | 1017 | Ajustar malha para manual | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | Deixar o modo fixado atual | Modo atual de deixar fixado- Leva uma saída analógica para fora do modo onde a saída foi um valor constant, e retorna a saída para o modo onde a saída segue a entrada | msrc_UNKNOWN | Details |
makeItSquawk | 101B | Squawk | Faça o Squawk do dispositivo de campo- Isso causa o dispositivo para alerta visualmente, audivelmente ou mecanicamente ou que permite os técnico para identificá-lo | msrc_UNKNOWN | Details |
send_warning | 1399 | Enviar alerta | Enviar alerta – Produzir uma notificação de código de unidades para o usuário | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |