Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
ejx_method_chg_pwon_info | 4172 | Chg power on info | Chg power on info- Change the information displayed when turn on the power. | msrc_UNKNOWN | Details |
display_power_on_info | 4173 | Abort of the Chg power on info | Abort of the Chg power on info- Display the power on information. | msrc_UNKNOWN | Details |
ejx_method_chg_univ_rev | 4174 | Chg universal rev | Chg universal rev- Change the universal command revision. | msrc_UNKNOWN | Details |
display_universal_rev_j | 4176 | Abort of the Chg universal rev | Abort of the Chg universal rev- Display the universal revision. | msrc_UNKNOWN | Details |
display_universal_rev_j_var | 4175 | Abort of the Chg universal rev | Abort of the Chg universal rev- Display the universal revision. | msrc_UNKNOWN | Details |
ejx_method_return_to_normal_for_zero_trim | 4156 | Abbruch Rückk. zu normal | msrc_UNKNOWN | Details | |
ejx_method_self_test | 400B | Selbsttest | Self Test- Commands the EJX electronics to perform a selftest. Reports any errors that occured. | msrc_UNKNOWN | Details |
ejx_method_master_test_exp_1 | 4159 | msrc_UNKNOWN | Details | ||
ejx_method_clear_dac_trim | 415A | Clear D/A trim | Clear digital to analog trim- Resets the trim adjustment to the initial calibrated values that were set at factory. | msrc_UNKNOWN | Details |
ejx_method_pres_trim | 4154 | Pres trim | Pressure trim- Executes full sensor trim with zero point adjustment by Lower Pt and span adjustment by Upper Pt. | msrc_UNKNOWN | Details |
ejx_method_clear_pres_sensor_trim | 4128 | Clear P snsr trim | Clear pressure sensor trim- Resets the trim adjustment to the initial calibrated values that were set at factory. | msrc_UNKNOWN | Details |
ejx_method_sp_trim | 4129 | Static Pres trim | Static pressure trim- Executes full sensor trim with zero point adjustment by Lower Pt and span adjustment by Upper Pt. | msrc_UNKNOWN | Details |
ejx_method_clear_sp_sensor_trim | 412B | Clear SP snsr trim | Clear static pressure sensor trim- Resets the trim adjustment to the initial calibrated values that were set at factory. | msrc_UNKNOWN | Details |
ejx_method_error_log_clear | 413D | Error log Clear | Error log clear- Clears the error records. | msrc_UNKNOWN | Details |
ejx_method_sp_apply_values | 4140 | SP Apply values | Werte übernehmen- Ausführung einer Bereichsneueinstellung durch übernahme der gewünschten Meßanfang und Meßende an dem Prozeßeingang des Gerätes | msrc_UNKNOWN | Details |
ejx_method_point_setting | 4145 | Point setting | Signal characterizer point setting- Sets the coordinates of break points to characterize the values in percent of the output. | msrc_UNKNOWN | Details |
ejx_method_do_test | 414A | DO Test | Digital output test- Allows the user to test the contact output for a digital signal at the contact output terminal of the device. Select 'On' to output the digital signal. | msrc_UNKNOWN | Details |
ejx_method_after_do_test | 415B | msrc_UNKNOWN | Details | ||
ejx_method_modify_engr_unit | 4150 | Modify Engr Unit | Modify engineering unit- Modifies the engineering unit or sets a customized engineering unit. Enter a series of up to eight alphanumeric characters, spaces, or slashes (only first six characters are shown on LCD). Note that if you already select the unit at 'Set Engineering Unit,' the unit appears as a default. Then re-enter the unit but enter a space instead of a character to display the character in lowercase on LCD. For example, in order to show 'aBCd' on LCD, enter 'ABCD' first, then enter '_BC_'. | msrc_UNKNOWN | Details |
ejx_method_test_key | 4019 | Test Key | msrc_UNKNOWN | Details | |
ejx_method_write_enable_10min | 4151 | Enable wrt 10min | Enable parameter change for 10 min.- releases the software write protection for 10 minutes when the password is entered. | msrc_UNKNOWN | Details |
ejx_method_change_to_new_password | 4152 | New password | New password- Sets or changes the password for software write protection. | msrc_UNKNOWN | Details |
err_abort_without_func_key_disp | 415C | Aborting | msrc_UNKNOWN | Details | |
normal_exit_for_chg_passwd | 415D | Exiting | msrc_UNKNOWN | Details | |
ejx_method_set_diag_mode | 4135 | Set Diag Mode | msrc_UNKNOWN | Details | |
ejx_method_zero_trim | 4153 | Pres Zero trim | Meßanfangs-Abgleich- Der Meßanfang wird dem aktuellen Sensoreingangswert gleichgestellt | msrc_UNKNOWN | Details |
ejx_method_error_log_view | 413C | Error log view | Error log view- Displays the error records from log1(latest) to log4. | msrc_UNKNOWN | Details |
ejx_method_set_engr_unit | 414F | Set Engr Unit | Set engineering unit- Selects the engineering unit from the list. | msrc_UNKNOWN | Details |
ejx_method_chk_supported_device | 4177 | msrc_UNKNOWN | Details | ||
ejx_method_engr_urv_lrv | 4208 | msrc_UNKNOWN | Details | ||
ejx_method_press_urv_lrv | 4210 | msrc_UNKNOWN | Details | ||
ejx_method_static_press_urv_lrv | 4214 | msrc_UNKNOWN | Details | ||
ejx_method_get_temp_usl_lsl | 4219 | msrc_UNKNOWN | Details | ||
ejx_method_master_test | 400C | Master Test | Master Reset- Commands the EJX electronics to reset and perform a selftest. Reports any errors that occured. | msrc_UNKNOWN | Details |
ejx_method_self_test_exp_1 | 4158 | msrc_UNKNOWN | Details | ||
ejx_method_reset_configuration_change_flag | 4181 | Reset Cfg chng flag | Reset Configuration changed flag. | msrc_UNKNOWN | Details |
ejx_method_simulate | 4180 | Simulate | Simulate. | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period1 | 41CC | Set Burst Period | Configure Burst Period | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period2 | 41CF | Set Burst Period | Configure Burst Period | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period3 | 41D2 | Set Burst Period | Configure Burst Period | msrc_UNKNOWN | Details |
ejx_method_set_burst_update_period_sub | 41D6 | msrc_UNKNOWN | Details | ||
ejx_method_set_burst_trigger1 | 41CB | Set Burst Trigger | Configure Burst Trigger | msrc_UNKNOWN | Details |
ejx_method_set_burst_trigger2 | 41CE | Set Burst Trigger | Configure Burst Trigger | msrc_UNKNOWN | Details |
ejx_method_set_burst_trigger3 | 41D1 | Set Burst Trigger | Configure Burst Trigger | msrc_UNKNOWN | Details |
ejx_method_set_burst_trigger_sub | 41D7 | msrc_UNKNOWN | Details | ||
ejx_method_event_time_setting | 41D4 | Set Event Notification Timing | Configure Event Notification Timing | msrc_UNKNOWN | Details |
ejx_method_applied_rerange | 4155 | Werte beaufschl. | Werte übernehmen- Ausführung einer Bereichsneueinstellung durch übernahme der gewünschten Meßanfang und Meßende an dem Prozeßeingang des Gerätes | msrc_UNKNOWN | Details |
ejx_method_scaled_dac_trim | 415E | Skal.D/A Abgleich | Digital zu Analog Abgleich- Ermöglicht den Abgleich der Endpunkten des Analogausgangs mit einer externen Referenz | msrc_UNKNOWN | Details |
ejx_method_acknowledge_event_notification | 418C | Acknowledge Event Notification | msrc_UNKNOWN | Details | |
ejx_method_squawk_exe | 41E1 | Squawk | Feldgerät sich bemerkbar machen lassen- veranlasst das Gerät einen visuellen, akustischen oder mechanischen Alarm auszugeben, um den Technikern eine Identifizierung zu ermöglichen | msrc_UNKNOWN | Details |
ejx_method_status_simulate | 41ED | Status simulate | Status Simulation allows a Field Device Status bit or a bit in the Command 48 response to be manipulated. | msrc_UNKNOWN | Details |
method_reset_cond_status_map | 4268 | Reset condensed status map | Reset the Condensed Status Map to the default values. | msrc_UNKNOWN | Details |
transmitter_loop_test | 1023 | Messkreistest | Meßkreistest- ermöglicht es, den Analogausgang manuell auf einen gewünschten konstanten Wert einzustellen | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Abbruch Rückk. zu normal | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | Fest-Stromausgang beenden | Konstantstrom Modus verlassen- Der Analogausgang war auf einen bestimmten Ausgangswert eingefroren. Es erfolgt die Rückkehr zu der Betriebsart, bei der der Analogausgang wieder dem Prozeßwert folgt | msrc_UNKNOWN | Details |
makeItSquawk | 101B | Squawk | Feldgerät sich bemerkbar machen lassen- veranlasst das Gerät einen visuellen, akustischen oder mechanischen Alarm auszugeben, um den Technikern eine Identifizierung zu ermöglichen | msrc_UNKNOWN | Details |
transmitter_dac_trim | 1024 | D/A Abgleich | Digital zu Analog Abgleich- Ermöglicht den Abgleich der Endpunkten des gewählten Analogausgangs mit einer externen Referenz | msrc_UNKNOWN | Details |
send_warning | 1399 | Sende Warnung | Sende Warnung- Mitteilung über Einheitcodes an den Anwender | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |